High Throughput And High Content Screening
What Is HTS ?
Biochemical target Test many compounds Compounds with desired effect on target =
Hit
Hit directly used as chemical probe to study target OR Hit provides structure for chemists to begin developing a drug or other product
HTS Technology
Robotics Miniaturization Sophisticated Assay Chemistry Sophisticated Software and Database
Evotec uHTS System
• • • • • • • • Opera High Content Detector Plate:vision detector for fluorescence (also fluorescence polarization & fluorescence resonance energy transfer), luminescence, absorbance 2 CO 2 incubators 4 low volume pipetting systems for 384 and 96-well plates (multidrops, Cy-Bi well, Cy-By drop) Plate washer Centrifuge Piercer Plate storage, barcode readers, lid handlers, transport systems
plate::vision detector
• CCD camara • Xenon lamp light source • Zeiss optics • Built in algorithm to correct for spherical lens aberration • 4 filter sets – Excitation filter – Emission filter – Dichroic filter
Opera
4 lasers 1 xenon lamp 4 CCD cameras 96- and 384-well plates Acapella image analysis software
Software Systems
Genedata • • • Assay Analyzer Condeseo Integrated with Opera Acapella image analysis software Accelyrs Accord • • HTS With Pipeline Pilot Ohio Third Frontier Computing Systems
HTS
Output is QUALITY DATA
Standard Screening Procedure
1 o HTS hits Triplicate assay confirmed HTS hits 10 point dose-response assay EC 50
HTS Assay Examples
• • • • • • • • • Receptor-binding • GPCR Enzyme • protease, kinase, phosphatase, lipase, others Bacterial growth Cell-based reporter gene Cell growth, cell viability Cytochrome P 450 Protein binding inhibition Protein production by cells ELISA
Examples of Assays:
Results from Enzyme Inhibition Screen 11,500 compounds screened Normalized results shown Each tile shows 1 plate of data
Right: Color Scale for Normalization Distribution of compound % Activity
Results from 1 plate in Enzyme Inhibition Screen
High Content Screening With the Evotec Opera
96-, 384-, and 1536-well plates Up to ~ 70 images per well in 384-well plate
Internalisation Assay Example
Image
Internalisation Assay Example
Image Analysis
Internalisation Assay Example
Opera External Data output
Excel spreadsheet spots / cell cell area nuclei area spots per cell 0.7
0.6
0.5
0.4
0.3
0.2
0.1
0 1 3 5 7 9 11 13 15 17 19 21 23 spots per cell
High Throughput & High Content Screening Services
Quality Data Experienced Scientists State-of-the Art Equipment