The HDMS experiment - RWTH Aachen University

Download Report

Transcript The HDMS experiment - RWTH Aachen University

The Heidelberg Dark Matter
Search Experiment
Laura Baudis
Stanford University
The HDMS collaboration
MPI fuer Kernphysik, Heidelberg
Group of Prof. H.V. Klapdor-Kleingrothaus
The HDMS detectors
WIMP
2 HPGe detectors in one
cryostat system
inner: WIMP target
outer: active veto
against multiple Comptons
passive Ge shield
gamma
Some detector properties
Property
Crystal type
Inner Detector
p-type
Outer Detector
n-type
Mass [g]
Active vol [cc]
Diameter [mm]
202
37
35.2
2111
383
84.4
Length [mm]
40.3
Op. bias [V]
+ 2500
FWHM @ 300 keV 1.2 (1.87)
(1332 keV) [keV]
86.2
-1500
3.2 (4.45)
Threshold [keV]
7.5
2.0
Cross talk between detectors
linear correlation:
correction offline
kio = 0.00375 +/0.43 x 10-4
koi = 0.12850 +/0.27 x 10-3
Cross talk induced error
compare zero energy
resolutions:
inner: no effect
outer: from 0.3% to
0.4% at 1332 keV
The HDMS detector
HDMS in Gran Sasso
prototype: March 98-July 99
Performance @ GS
stable running over ~ 15 months
individual runs ~ 0.9 d
checked daily: leakage current
nitrogen flow
overall trigger
individual count rate, etc
weekly: calibration with 133Ba, 152Eu-232Th source
Outer detector: 363 raw live-d
68Ge, 57Co, 58Co, 54Mn, 60Co, 65Zn, 137Cs, 238U, 232Th, 40K
Inner detector: 363 raw live-d
68Ge, 54Mn, 57Co, 60Co, 210Pb, 212Pb, 214Pb, 40K
Background model
MC simulation of dominant backgrd.
sources with extended GEANT3.21
Inner: low energy spectrum
68Ga
X-ray
49Ti, 55Mn
cross talk?
Structure at 32 keV: cross talk?
Anticoincidence between inner and outer
Eth for anticoincidence: 3 sigma away from zero
threshold
[keV]
FWHM/2.35
[keV]
3s
inner
2.0
0.40
1.2 keV
outer
7.5
1.42
4.3 keV
40-100 keV: factor 4.3
11-40 keV: 0.2 events/kg d keV
40-100 keV: 0.07 events/kg d keV
HDMS prototype limits
only last 49 d of data taking: 9.9 kg d
2-30 keV: 0.5 events/kg y keV
L. Baudis et al., PRD63,2000
73Ge-HDMS:
full scale
inner crystal replaced by 73Ge crystal
sensitive to spin-dependent interactions
70Ge de-enriched by factor >50
new copper holder system
no soldering of contacts
installed in GS: August 2000
working well
first analysis: fall 2001?
expectation: test DAMA with
independent technique and raw data
HDMS goal
Based on: 0.07 events/kg d keV in 2 - 30 keV region
Conclusions
HDMS prototype worked well
limits competitive to other Ge experiments
73Ge-HDMS
installed in August 2000
first 73Ge detector!
first data to be analyzed soon...
independent test of DAMA region
sensitive to spin-dependent interaction
however, increase of target mass improbable
no sensitivity to a WIMP signature