Transcript VX-2000
ena s M Voice Evacuation New Alarm System bc History From Background Music to Automatic Voice Alarms For a long time PA systems have been used to distribute background music and paging announcements into public areas • Nowadays these PA systems that have evolved into Integrated Voice Evacuation systems, are used to warn people who face various life threatening situations • In an emergency situation it has become essential to have Automatic Voice Alarms in conjunction with Alarms. Voice Alarm Systems 2 bc Security Voice Alarm Systems Clear instructions allow a controlled evacuation without panic The requirements for a secure Voice Alarm System are written in the European standard EN 60849 TOA follows these requirements with its systems of the Venas - Range 3 bc Venas Systems VM-2000-Series The integrated PA System Manager for small to medium sized PA systems, 120 or 240 watts VX-2000-Series The modular System for medium to large PA systems Fully compatible with EN 60849 Easy system configuration via PC Easy maintenance via PC 4 VX-2000 Secure Security bc VX-2000 System Applications Announcement Background music Alarm Connections 8 Inputs 128 Control Inputs VX-2000 Surveillance acc. to EN 60849 Security RS 232C Redundancy, Economy Mode 50 Speaker Lines 128 Control Outputs Easy Maintenance 6 bc VX-2000 System Applications Background Music VX-2000 7 bc Background Music Matching Modules for Different Sources different jacks: Cinch, XLR, phone and screw terminal balanced or unbalanced with or without variable high- and low pass filter gain adjustment Easy call up of signal distribution into several zones VX-2000 Tuner 8 bc VX-2000 System Applications Background Music Announcement VX-2000 9 bc Announcement (1) System’s Remote Microphone • Up to 8 remote microphones • Free programmable buttons • Expandable up to 105 buttons • Announcements *individual into each zone *into groups of zones *All-call *with or without pre/post chime *4 different chime sounds • Permanent or non-permanent talk button • adjustable off-time for permanent talk button covered alarm button 10 bc Announcement (2) Standard Remote Microphone Programmable access to certain zones 2 optional Voice Announcement Boards EV-200 Playback of up to 16 pre-recorded messages manually activated announcements Timer-controlled announcements Programmable access of certain messages to certain zones 11 bc VX-2000 System Applications Background Music Announcement Alarm VX-2000 12 bc Alarm (1) Voice-Alarm with Pre-Recorded Messages Automatic Alarm Control via Fire Detecting System Warning and Evacuation programmable for each fire area Manual Alarm Control from system’s remote microphone via covered Alarm button • Warning or evacuation programmable Control from Fireman’s Microphone • selectable warning message for selectable fire areas • selectable evacuation message for selectable fire 13 areas bc Alarm (2) Fireman’s Microphone • Acoustically monitored rigid microphone • Free programmable buttons Activation warning message Activation evacuation message Activation all-clear message Zone selection for paging Failure indication • Expandable up to 105 buttons • All-call paging possible in case of CPU failure 14 bc Automatic Fire Area Related Alarm (Example) Tower Building with Several Fire Areas • Fire in the 5th floor • the fire detecting system (FDS) controls the VX-2000 specifically • The VX-2000 starts an Evacuation message for the 5th and 6th floor • It also starts a Warning message for the other floors simultaneously • The fire increases • The fire detecting system controls further control inputs of the VX-2000 VX-2000 • The VX-2000 starts an Evacuation message for all FDS floors 15 bc Manual Intervention into the Automatic Alarm (Example) The Fireman Operates the Fireman’s Microphone • Fire on the 5th floor. The automatic evacuation message is broadcast to the 5th and 6th floor, and a warning message to the other floors • The fireman decides to evacuate all upper floors. He manually activates the evacuation message for these areas on the fireman’s microphone • The fire is extinguished. The VX-2000 fireman activates the all-clear message on the fireman’s FDS microphone. 16 bc VX-2000 System Application Background Music 8 Inputs 128 Control Inputs Announcement Alarm Connections VX-2000 17 bc Inputs Audio Inputs 8 Module Slots for connection of up to 15 sound sources (8 system remote microphones, 7 further sources) different jacks: Cinch, XLR, phone, screw terminal, RJ45 balanced or unbalanced with or without variable high and low pass filter gain control Control Inputs 16 control inputs at the matrix expandable up to 128 control inputs 18 bc VX-2000 System Application Background Music 8 Inputs 128 Control Inputs Announcement Alarm Connections VX-2000 50 Speaker Lines 128 Control Outputs 19 bc Outputs 50 Speaker Lines 100 Volt Amplifier with: 4 x 60 W 2 x 120 W 1 x 240 W 1 x 420 W full surveillance Control Outputs: •16 control outputs on the matrix •expandable up to 128 control outputs 20 bc VX-2000 System Applications Background Music 8 Inputs 128 Control Inputs Announcement Alarm Connections VX-2000 RS 232C 50 Speaker Lines 128 Steuerausgänge 21 bc RS 232C Interface Connection with PC Easy-to-Use Software on Windows™ Configuration of the system Maintenance and inspection Reading the log file 22 bc VX-2000 System Application Background Music 8 Inputs 128 Control Inputs Announcement Alarm Connections VX-2000 RS 232C 50 Speaker Lines 128 Control Outputs Surveillance acc. to EN 60849 Security 23 Surveillance of the Critical Signal Path bc Surveillance of The Audio Paths Without Gap microphone capsule, acoustically preamplifier preamplifier internal signal path power amplifier Matrix System microphone cable connection line preamplifier connection line speaker circuit 24 bc Surveillance of the System Availability Power Supply and Controls Power Supply AC mains power supply Fuses Matrix System CPU Communication line CPU Battery Secondary power supply 25 bc Failure Signalization (1) On the System’s Remote Microphone Fixed indication: Any failure Line failure on the zone buttons Free programmable Failure of a certain part (e.g. battery) Failure of a group (e.g. amplifiers) with acoustical signalization according to EN 60849 Receipt button 26 bc Failure Signalization (2) Via Control Outputs Any combination of single failures : Failure of a certain element (e.g. battery) Failure Group (e.g. amplifiers) any (possible) failure to be indicated on the fireman’s panel for automatic control of replacement devices (if not available with the system already) 27 bc VX-2000 System Application Background Music 8 Inputs 128 Control Inputs Surveillance acc. to EN 60849 Security Announcement Alarm Connections VX-2000 RS 232C Redundancy, Economy Mode 50 speaker lines 128 Control Outputs 28 Redundancy, Economy Mode bc (1) Redundancy Automatic Switch-Over to Stand-by Amplifier Power Supply can be designed redundant (at a power supply unit’s loss, another power supply unit takes over the supply) If the CPU fails, it is still possible to make an all-call from the fireman’s microphone Automatic Reset Surveillance and automatic Reset of the CPU via Watchdog timer 29 bc Redundancy, Economy Mode (2) Economy Mode Stand-by Function of Power Amplifiers In economy mode, the power consumption of the power amplifiers is reduced when not in use At battery operation the current consumption is extremely reduced, and the battery’s capacity can be designed lower than usual quick readiness of the power amplifiers 30 bc VX-2000 System Application Background Music 8 Inputs 128 Control Inputs Surveillance acc. to EN 60849 Security Announcement Alarm Connections VX-2000 RS 232C Redundancy, Economy Mode 50 speaker lines 128 Control Outputs Installation & Maintenance 31 Installation & Maintenance bc Maintenance Software on Windows™ Installation Support Initial measuring of the speaker lines via PC Easy Maintenance Configuration Check Comparison PC setting - system setting Connection Check Check of all internal wiring Surveillance Check automatic check of all monitored elements, manual check of the buttons Emergency Check Check of the emergency functions with or without broadcast of warning and evacuation messages 32 bc VX-2000 System Background Music Announcement Alarm 8 Inputs 50 Speaker lines 128 Control Inputs Surveillance acc. to EN 60849 Venas VX-2000 RS 232C Redundancy, Economy Mode 128 Control Outputs Installation & Maintenance ... even more than EN 60849 33 Venas We want to inform you ... ... just ask…..