Transcript Document

FEATURED PRODUCTS

LiNC-PLUS • LiNC-NET • LiNC-Ez • IQ Series • FT Series

Scaleable System Capacities & Functions

Available in a Variety of Software Packages to support Small, Medium and Large Single-user / Multi-user System requirements. It can be easily expanded by integrating additional LiNC-PLUS software modules and security products from across the industry.

LiNC-PLUS Continued

LiNC-PLUS

is a complete scaleable PC-based software package designed to integrate, control and manage electronic security and building automation components with sub systems into a networked Integrated Security management System.

HIGHLIGHTED FEATURES           User-Defined Graphical Interface Full Graphical Drag-and-Drop Configuration User-Defined Functionality ODBC Compliant Database Manager Standard and User-Defined Reports Native Client/Server Architecture Software Only Packages Available Closed Circuit Television Matrix Switchers Digital Video Multiplexers & Recorders Intercom, Paging & Communication Systems           Time Lapse Video Recorders Perimeter & Fence Detection Systems Parking & Gate Control Systems Text-to-Speech Annunciation Module (TSA) On-Screen Live Video Display (LVD) Card Management Module (CMS) Video Badging Module (VBS) Ethernet LAN/WAN Compatibility TCP/IP Protocol, standard Software and PC Hardware Packages Available

Facility Management at Your Fingertips

Through door control, video badging, elevator control and alarm graphics, LiNC-NET provides facility managers with physical control of the building as well as the information to analyze history and trends.

LiNC-NET Continued

LiNC-NET

for Windows is a fully integrated, scalable access control and security management solution designed for all type and size facility applications. From one door to thousands of doors, the system’s capability in conjunction with PCSC controllers provide world-class security and facility management through multiple types of feature benefits.

HIGHLIGHTED FEATURES                Password / Level Control Functions Password Controlled Data Segregation Operator Audit Password Controlled Admin and / or User Menus Bulk Activation or Deactivation by Affiliation Supervisor & Visitor Controlled Access Long Access / Handicapped Access Access Actions by Cardholder or Group Operator Solicited Open Door Two Person Minimum Occupancy Rule Auto System Shutdown Prior to Battery Failure Auto Door Opening by Time or Supervisor Auto Card Expiration by Date Auto User Scheduled Reports Auto Daylight Savings Control                User Defined Reports Intelligent Floor Control Floor Destination Reporting 5 State Alarm Monitoring Occurred and Logged History Time Stamp Regional, Strict / Lenient & Soft Anti-Passback 3 Level Entry / Exit Nesting Network Status with Firmware Verification User Selectable Alarm Type Individual Alarm Latching Selection User Defined Input/Output Polarity Priority Alarm Processing Integrated Video Badging & Alarm Graphics Integrated CCTV Available in Foreign Languages

TM

Easy to install, easy to program, easy to expand

PCSC’s entry level building management system designed for site applications with access control and alarm monitoring needs. With preprogrammed access parameters and schedules, LiNC-Ez is ready to use immediately after installation. Designed to control up to 32 intelligent controllers or 64 doors.

   HIGHLIGHTED FEATURES          Automatic Program Installation and Setup 12,000 Cardholders and Up to 64 Readers 5,000 History Transactions Standalone, 50,000 on System Handicapped Access Entry Automatic Card Activation and Deactivation Auto Holiday, Leap Year & Daylight Savings Control User-friendly Reports Electronic Update of Firmware Communicates via RS-485, Dial-up Modems, Ethernet LAN* or ZigBee™ Pro Wireless Easy Device Installation Photo Image Importing Timed Anti-passback

Intelligent Access Control for Any Need

Modular upgrades with add-on readers, inputs and outputs are engineered into the IQ Series design enabling you to dynamically configure a custom security system with standard off the shelf components.

IQ Series Continued

IQ Series

are PCSC’s benchmark for access control, input and output control monitoring. System configuration begins with either a two door controller (IQ 200) or a four door controller (IQ 400). Each controller can be expanded in 4 reader increments, up to 10 or 12 readers.

HIGHLIGHTED FEATURES                     Legacy Upgrade Capable 100% Distributed Intelligence Open Architecture Handicapped Access Automatic Card Deactivation by Date Card Action User Specified Supervised or Digital Sense Input Definition High Security 5 State Alarm Supervision Dynamic Input to Output Linking User Programmable Input/Output Logic Supervisory Access Authorization Logic Two Person Minimum Occupancy Rule 3 Tier Anti-Passback Supervised Readers Electronic Firmware Updates Real-time Diagnostics AC Power Fail Indication DC Power Low Indication UL 294, 1076, AUSTEL and CE Listed HIGHLIGHTED CAPACITIES          2, 4, 6, 8, 10 or 12 Reader Configurations* 8,000 to 20,000 or 50,000 Cardholders* 4,000 to 10,000 History Transactions* 16 Site Codes 4 Authorization Groups per Cardholder 64 Time Periods with 7 Segments Per Period 366 Holidays (Leap Year) 1 Yr. Battery Backed Clock Calendar and Memory Optional Universal Power Supply (90-250 VAC) COMMUNICATIONS SUPPORTED       RS485 or RS 232 Dial-up Modem Leased Line Wireless Fiber Optics 10/100 TCP/IP Ethernet (optional)

The Word’s First Fault Tolerant Security System

a high availability access control system with redundant host, controllers, and communication. A peer-to-peer network of master controllers and door interface modules can provide for a level of reliability that is required in today’s security environment but has, until now, been unavailable. Patent Pending

IQ Series Continued

FT Controller

A system unlike any other in the world; in the event of a hardware or firmware failure, a redundant FTC automatically assumes the duties of the failed device. This enables a redundant operation at all levels of the system architecture without degradation in operation or security.

SYSTEM FEATURES                    Fault Tolerant Process Automatic Hot Cutover Fail Safe Operations Open Systems Platform Open Architecture Protocol Peer to Peer Communications Homeland Security Threat Level Control Automatic Alternate Communication Routing - Up to 3 Access Action for Disabled Persons Supervisory Controlled Entry Authorization Event Control Card Logic Cardholder or Card Group Action User Programmable Input Action Dynamic Input to Output or Group Output Linking Global Anti-Passback 3 Levels of Anti-Passback Control Auto Card Activation & Deactivation by Date & Time User Configurable Cardholder and History Capacity User Selectable Input Monitoring Modes       HIGHLIGHTED CAPACITIES   25,000 - 200,000 Cardholders (user configurable) 20,000 - 60,000 History Transactions (user configurable) 1 to 32 Readers per Master Controller Simultaneous Multi Card Format Recognition Multiple Site Codes (16) 16 to 512 Five-State Inputs Supervision* 16 to 512 Temperature Monitoring* 16 to 512 Relay Outputs* COMMUNICATIONS SUPPORTED      10/100 TCP/IP (Standard) PoE (Power over Ethernet) ZigBee™ Pro Wireless with MESH Technology WiFi RS 232C or RS 485

Access Innovators Since 1983

800.899.PCSC

www.1pcsc.com