36G Gas Valve Preso

Download Report

Transcript 36G Gas Valve Preso

New Valve
White Rodgers 36G
Old Valve/Replacement Valve
‘36F’
36G Gas Valve
36G22 Gas Valve Non-Direct Vent
Nylon plug
No barb fitting
36G Gas Valve
Pressure
“IN” Test
Port
Pressure Adjust
36G22 Gas Valve Direct Vent
Manifold
“OUT”
Pressure
Test Port
Vent Port
36G Single Stage Gas Valve
» Out with the “Old”, In with the “New”
36E/F Single Stage
Gemini Platform
36G Single Stage

Gemini Flow Path Single Stage
Gemini Service Features 36G Single Stage
Adjustable
Regulator
ON/OFF
Switch
Vent
Outlet
Pressure Tap
Inlet
Pressure Tap
36G Two Stage Gas Valve
» Out with the “Old”, In with the “New”
Gemini Platform
36G Two Stage
36E Two Stage

Gemini Flow Path Two Stage
Gemini Service Features 36G Two Stage
Two Adjustable
Regulators (Low & High)
ON/OFF
Switch
Vent
Outlet
Pressure Tap
Inlet
Pressure Tap
LP GAS CONVERSION
BAYLPKT210A LP Kit
BAYLPKT210B LP Kit
BAYLPSS210B LP Kit
Gas Valve cont.
• Adjusting valve “G” See Note: When
converting to LP (spring goes in HI side
only) you must first turn HI fire
adjustment spring clockwise till it
bottoms or you will not be able to adjust
LO fire.
• What units have “G” valve on them????
• *UY & *DT-R-A
• What unit can the “G” valve be used as a
replacement on????
• *UD & *DD-R-A
PAGE 30