Preliminary Design of the Full‐Stokes UV and Visible

Download Report

Transcript Preliminary Design of the Full‐Stokes UV and Visible

Preliminary Design of the
Spectropolarimeter for Arago
Martin Pertenaïs1,2
Coralie Neiner1 (PI), Laurent Parès2, Jean-Michel Reess1, Pernelle Bernardi1, Frans Snik3, Gerard van Harten3
1Paris
Observatory (FR)
2IRAP-CNRS, University of Toulouse (FR)
3Leiden Observatory, Leiden Univsersity (NL)
Punta Leona
2nd
December 2014
1
François Arago
1811 : Arago discovered rotary polarization experimentally (Quartz)
Polarimetry was born !!
2
Scientific goals
• What is the life cycle of matter ? (star formation, evolution and death)




ISM Characterization
Young (PMS) stars in accretion
All kinds of stars (Massive stars, Solar-like stars…)
Late stages of evolution (Supergiants, supernovae,…)
• How do stars impact the formation of planets and the emergence of life?
 Star-Planet interactions (stellar wind, magnetic interaction,…)
 Space weather (irradiation of the planet by the star,…)
3
Specifications
Specification
Requirement
Spectral range
[119 nm ; 888 nm]
UV Resolution
25 000
Visible Resolution
35 000
S/N
100
Typical exp. time
30 min (OBA stars, V=7)
1h (FGK stars, V=7)
Target Magnitude
V=3-10
Vrad accuracy
1 km.s-1 (in absolute)
0.1 km.s-1 (for magnetic fields measurement)
Polarization accuracy
10-3
4
Instrument Scheme
5
Telescope
Spec. :
- SNR 100
- V=7 Star
- 30 min exposure time
 1.3m diameter
Cassegrain telescope
F/13
6
Instrument Scheme
7
Polarimeter
Aim : create a polychromatic polarimetric modulator
•
4 MgF2 stacked wave plates with fast-axis angle and thicknesses:
(a1,d1), (a2,d2),(a3,d3),(a4,d4)
•
Optimization on these 8 variables
•
The stack of the 4 plates takes 6 different angular positions (0°,30°,60°,90°,120° et 150°)
d1
a1
d2
a2
d3
a3
d4
a4
8
Polarimeter
Aim : create a polychromatic polarimetric modulator
•
Definition of a demodulation matrix D such as:
•
The extraction efficiencies of the Stokes parameters *:
Sin=D.Iout
−1/2
𝑛
2
𝐷𝑖𝑗
𝜖𝑖 = 𝑛
𝑗=1
1
•
The optimal efficiency for Q, U and V is
•
The extraction is achromatized and not the retardance of the plates!
3
≈57.7%
* Optimum modulation and demodulation matrices for solar polarimetry, JC del Toro Inista and Collados (2000)
9
Polarimeter
10
Instrument Scheme
11
Spectrograph
12
Instrument Scheme
Classical CCD
detector (13µm
pixel pitch)
MCP Detectors
(20µm pixel pitch)
13
To take home
• High-resolution spectropolarimetry
• Precise Full Stokes (IQUV) measurement
• From FUV (119 nm) to NIR (888 nm)
• Exciting science !
Thank you for your attention !
Contacts : [email protected]
[email protected]
14
15
Thank you for
your attention !
16
SNR figures
T=9790 K
Mag = 10
Exposure Time = 30min
SNR
SNR
T=16000 K
Mag = 7
Exposure Time = 30min
Wavelength (nm)
Wavelength (nm)
Considering an optical transmission in the UV of 3% and 10% in the VIS,
and a quantum efficiency in the UV of 35% and 70% in the visible
17
Spectral band
Visible
[390-890] nm
UV
[119-320] nm
UV
[119-320] nm
UV
[119-320] nm
Minimum
SNR
Magnitude V
Spectral type
Maximum exposure time [min]
100
7
all
30
100
7
OBA
30
100
7
FGK
60
100
10
Chromospheric emission lines
of M dwarfs
60
18
Birefringence MgF2
19
Focal planes
Frame size 120 x 14 mm
UV
100 mm
Visible :
Frame size 30 x 30 mm
20
Back-up polarimeter
x
x
2x


x

6 tan(x ) n( )
𝐼𝑜𝑢𝑡
= 0,5(𝐼 + 𝑄 cos Φ𝑐𝑜𝑠2𝜃 + 𝑠𝑖𝑛Φsin2θ
+ Ucos2Φsin2θ
21