Transcript Bild 1
CO2 Heat pump Kick Off Meeting The Natural Refrigerant, The Natural Choice Maarud gård, Norge 22 April 2008 SANYO Air Conditioners Europe Kjell Lundén Looking at the house you have to consider: • Which year the house was built and ev. improvements • Number of residents • Living area (heated area) • Energy consumption • Plot of land and its location Windows +5° 0° -5° -10° -15° 2-glass windows Standard 3glass windows Energy effective 3glass windows Where goes the energy? Ventilation 30% Roof 15% Windows 25% Outer walls 15% Floor & Basement 15% Old plankhouse with extreme high energy consumption Roof U=0.5 Windows U=3.0 Outer walls U=1.0 Base U=1.0 Usage of energy Household electricity Heating of the house 5000 kWh/year 15000 kWh/year or around 60% Hot water 5000 kWh/year Energy for heating / year -30° T e m p e r a t u r e / e f f e c t Maximum power requirement at lowest temperature 60% of the highest power requirment ------------------------------------ Days 50 100 150 200 250 300 350 Kostnadseffektivitet • - 1990: Vedeldning • 1990 - 2005: Bergvärme • 2005 - ? : Sanyos CO-2 teknik Borrhål Att tänka på • Tidigare energiförbrukning ska kunna motsvaras av värmepumpen. • Viktigt att kunden håller en så låg framledningstemperatur som möjligt. • Fler radiatorer eller luftkonvektor sänker framledningstemperaturen. • Tumregel: Framledningstemperaturen bör aldrig överstiga 50°C, för optimal besparing. • Rekommendera alltid markstativ. Plumbing 01 Sanyo CO2 Eco 02 Mixing valve, automatized 03 Circulation pump, radiator system 04 Adjustment valve for radiator coils 05 Radiators 06 Radiator thermostatic valves 07 Shut off valve for the radiator system 08 System/boiler pressure, install on the return pipe 09 Expansion vessel, closed (recommended) 10 Expansion vessel, open (alternative) 11 Filling valve for radiator system 12 Safety valve (factory mounted) 13 Safety valve for hot water coil 14 Mixing valve for hot water 15 Non-return valve for incoming cold water 16 Taps 17 Incoming cold water 18 Load circulation pump 19 Insulated pipes 20 Flexible houses 21 Heat pump unit 22 Shut-off valves 23 Drain valve Installation of systems with radiators HP Unit 931 Outdoor Indoor Heating circuit Water Supply Radiator Mix.V 1230 Tank Unit Circulation between HP and tank 597 Installation of systems with radiators and floor heating Heating circuit Outdoor Indoor 931 Water Supply Radiator HP Unit Mix.V Tank Unit 1230 Mix.V Circulation between HP and tank 597 ND10 Floor heating ????????? Tank structure Returledning till Nedre skikt Övre skiktplåt Ifrån VP till tankens mellanskikt Till VP ifrån Nedre skikt Nedre skiktplåt Tank Structure 2 Domestic hot water outlet (Ø22 mm out) Domestic cold water inlet (Ø22 mm out) Waste water pipe connection (Ø22 mm in) Expansion pipe connection (DN 20 in) From heat pump. Connection (Ø22 mm out) To heat pump. Connection (Ø22 mm out) Primary flow out connection (Ø22 mm in) Primary flow return connection (Ø22 mm out) Lifting device (DN 20 in). Not a water connection. Limitations Pipe maximum length 15 m Limitations Rörchema Electrical parts Electric box Electronic PCB Electronic PCB Cable fixings Main power supply connectors Lower electrical immersion Cable intake heater Cable fixing Wiring Wiring Wiring Connections Elinkoppling PANEL Display normalläge CO2 ECO RUM 21 °C Tanktemp. Ute temp. Status: Måndag 20:45 Manuell avfrostning (21.5 °C) 50 °C 3 °C Nej Huvudmeny Logg Diagnos Inställningar Inställningar kodad Manuell drift (Inställning tid) Meny Logg Total drifttid 15351 h Total kompressor 7350 h Kompressor/24 h 17:32 h Start komp./24 h 2 Senast larm: 1. Utegivare 2. 3. - Meny Diagnos sid 1 Kompr effekt Elpanna Elpanna temp El nedre El nedre temp Rumstemp Utetemp Tanktemp Radiator temp 82 Hz 0 kw (55°C) 55°C 0 kW 45°C (21,5 °C) 21 °C 3 °C (50 °C) 44 °C (40 °C) 40 °C Meny Diagnos sid 2 Ström Shuntventil Laddpump VP vatten in VP vatten ut Kompr temp Utetemp VP Fördröjn. El (25A) 12A + 99% 37 °C 55 °C 90 °C 1 °C Ej aktiv Meny Diagnos sid 3 Kommunikation OK Program ID Program datum XXXXXXX XX-XX-XX Meny Inställningar sid 1 Språk Värmepump Huvudsäkring Fördröjning elpanna Elpanna Max elpanna El nedre Max el nedre Swe Ja 20 A 3h 50 °C 6 kw 45°C 6 kW Meny Inställningar sid 2 Sommargräns Rumsgivare Max framledning Min framledning Huskurva Justering Huskurva Temp sänkning Rum / Framl ändras 17°C Ja 55 °C Av 50 °C 0 °C Nej 0 °C Meny Inställningar sid 3 Tider Måndag Tisdag Onsdag Torsdag Fredag Lördag Söndag ▲06▼--▲--▼22 ▲06▼--▲--▼22 ▲06▼--▲--▼22 ▲06▼--▲--▼22 ▲06▼--▲--▼22 ▲06▼--▲--▼22 ▲06▼--▲--▼22 Meny Inställningar kodad 276 Kod Tank Max Tank Min A Tank Min B Tank min gräns Min Pump hast Diff Start / Stopp Frysgräns 276 65 °C 43 °C 50 °C 5 °C 10% 5 °C 2 °C Meny Manuell Värmepump () Pumphast 0% Relä 1.5( ) 3( ) 4,5( ) 6( ) 7,5( ) 9( ) Relä nedre 3() 6() Shuntventil () Rumsgivare fel () Meny Inställning tid Inställning Tid Måndag Timme Minut 00: 00: Let’s go with the natural choice!