Transcript Bild 1

CO2 Heat pump Kick Off Meeting
The Natural Refrigerant, The Natural Choice
Maarud gård, Norge
22 April 2008
SANYO Air Conditioners Europe
Kjell Lundén
Looking at the house you
have to consider:
• Which year the house was built and ev.
improvements
• Number of residents
• Living area (heated area)
• Energy consumption
• Plot of land and its location
Windows
+5°
0°
-5°
-10°
-15°
2-glass
windows
Standard 3glass windows
Energy
effective 3glass windows
Where goes the energy?
Ventilation 30%
Roof 15%
Windows 25%
Outer walls 15%
Floor & Basement 15%
Old plankhouse with extreme high
energy consumption
Roof U=0.5
Windows U=3.0
Outer walls U=1.0
Base U=1.0
Usage of energy
Household electricity
Heating of the house
5000 kWh/year
15000 kWh/year or around 60%
Hot water
5000 kWh/year
Energy for heating / year
-30°
T
e
m
p
e
r
a
t
u
r
e
/
e
f
f
e
c
t
Maximum power requirement at lowest temperature
60% of the highest power requirment
------------------------------------
Days
50
100
150
200
250
300
350
Kostnadseffektivitet
•
- 1990: Vedeldning
• 1990 - 2005: Bergvärme
• 2005 - ? : Sanyos CO-2 teknik
Borrhål
Att tänka på
• Tidigare energiförbrukning ska kunna
motsvaras av värmepumpen.
• Viktigt att kunden håller en så låg
framledningstemperatur som möjligt.
• Fler radiatorer eller luftkonvektor sänker
framledningstemperaturen.
• Tumregel: Framledningstemperaturen bör
aldrig överstiga 50°C, för optimal
besparing.
• Rekommendera alltid markstativ.
Plumbing
01 Sanyo CO2 Eco
02 Mixing valve, automatized
03 Circulation pump, radiator system
04 Adjustment valve for radiator coils
05 Radiators
06 Radiator thermostatic valves
07 Shut off valve for the radiator system
08 System/boiler pressure,
install on the return pipe
09 Expansion vessel, closed
(recommended)
10 Expansion vessel, open (alternative)
11 Filling valve for radiator system
12 Safety valve (factory mounted)
13 Safety valve for hot water coil
14 Mixing valve for hot water
15 Non-return valve for incoming cold water
16 Taps
17 Incoming cold water
18 Load circulation pump
19 Insulated pipes
20 Flexible houses
21 Heat pump unit
22 Shut-off valves
23 Drain valve
Installation of systems with radiators
HP Unit
931
Outdoor
Indoor
Heating
circuit
Water
Supply
Radiator
Mix.V
1230
Tank
Unit
Circulation
between HP and tank
597
Installation of systems with radiators and floor heating
Heating
circuit
Outdoor
Indoor
931
Water
Supply
Radiator
HP Unit
Mix.V
Tank
Unit
1230
Mix.V
Circulation
between HP and tank
597
ND10
Floor heating
?????????
Tank structure
Returledning till
Nedre skikt
Övre skiktplåt
Ifrån VP till
tankens
mellanskikt
Till VP ifrån
Nedre skikt
Nedre skiktplåt
Tank Structure 2
Domestic hot water
outlet (Ø22 mm out)
Domestic cold water
inlet (Ø22 mm out)
Waste water pipe
connection (Ø22 mm
in)
Expansion
pipe
connection (DN 20 in)
From heat
pump.
Connection
(Ø22
mm
out)
To
heat
pump.
Connection
(Ø22
mm
out)
Primary flow out
connection (Ø22 mm
in)
Primary flow return
connection (Ø22 mm
out)
Lifting device (DN 20
in). Not a water
connection.
Limitations
Pipe maximum length 15 m
Limitations
Rörchema
Electrical parts
Electric box
Electronic
PCB
Electronic
PCB
Cable fixings
Main
power
supply
connectors
Lower
electrical
immersion
Cable intake
heater
Cable fixing
Wiring
Wiring
Wiring
Connections
Elinkoppling
PANEL
Display normalläge
CO2 ECO
RUM
21 °C
Tanktemp.
Ute temp.
Status:
Måndag 20:45
Manuell avfrostning
(21.5 °C)
50 °C
3 °C
Nej
Huvudmeny
Logg
Diagnos
Inställningar
Inställningar kodad
Manuell drift
(Inställning tid)
Meny Logg
Total drifttid
15351 h
Total kompressor 7350 h
Kompressor/24 h 17:32 h
Start komp./24 h
2
Senast larm:
1. Utegivare
2. 3. -
Meny Diagnos sid 1
Kompr effekt
Elpanna
Elpanna temp
El nedre
El nedre temp
Rumstemp
Utetemp
Tanktemp
Radiator temp
82 Hz
0 kw
(55°C) 55°C
0 kW
45°C
(21,5 °C) 21 °C
3 °C
(50 °C) 44 °C
(40 °C) 40 °C
Meny Diagnos sid 2
Ström
Shuntventil
Laddpump
VP vatten in
VP vatten ut
Kompr temp
Utetemp VP
Fördröjn. El
(25A) 12A
+
99%
37 °C
55 °C
90 °C
1 °C
Ej aktiv
Meny Diagnos sid 3
Kommunikation
OK
Program ID
Program datum
XXXXXXX
XX-XX-XX
Meny Inställningar sid 1
Språk
Värmepump
Huvudsäkring
Fördröjning elpanna
Elpanna
Max elpanna
El nedre
Max el nedre
Swe
Ja
20 A
3h
50 °C
6 kw
45°C
6 kW
Meny Inställningar sid 2
Sommargräns
Rumsgivare
Max framledning
Min framledning
Huskurva
Justering Huskurva
Temp sänkning
Rum / Framl ändras
17°C
Ja
55 °C
Av
50 °C
0 °C
Nej
0 °C
Meny Inställningar sid 3
Tider
Måndag
Tisdag
Onsdag
Torsdag
Fredag
Lördag
Söndag
▲06▼--▲--▼22
▲06▼--▲--▼22
▲06▼--▲--▼22
▲06▼--▲--▼22
▲06▼--▲--▼22
▲06▼--▲--▼22
▲06▼--▲--▼22
Meny Inställningar kodad 276
Kod
Tank Max
Tank Min A
Tank Min B
Tank min gräns
Min Pump hast
Diff Start / Stopp
Frysgräns
276
65 °C
43 °C
50 °C
5 °C
10%
5 °C
2 °C
Meny Manuell
Värmepump
()
Pumphast
0%
Relä
1.5( ) 3( ) 4,5( ) 6( ) 7,5( ) 9( )
Relä nedre
3() 6()
Shuntventil
()
Rumsgivare fel
()
Meny Inställning tid
Inställning Tid
Måndag
Timme
Minut
00:
00:
Let’s go with the natural choice!