eMerge Certification Module 1

Download Report

Transcript eMerge Certification Module 1

Revision d1

Browser Managed Security Platform

Product Training & Certification

Browser Managed Security Platform

Networking Basics

Revision d1

What is a network?

Network Bandwidth

IP Addresses & Subnet Masks

Ports & Port Usage

Planning a Network

Revision d1

Networking Basics

What is a Network? Internet WAN side Network LAN side A Network is a collection of devices linked by a common communications infrastructure. The most widely used type is known as Ethernet.

Revision d1

Networking Basics

What is a Network? Internet WAN side LAN side Network A network can be a Local Area Network (LAN) or a Wide Area Network (WAN).

Revision d1

Networking Basics

What is a Network? Internet WAN side LAN side Network Networks are often drawn as a pipe, as in a “data pipe” because data flows through it.

Revision d1

Networking Basics

What is a Network? Internet WAN side Network LAN side The “cloud” typically represents wide area network components such as the Internet

Revision d1

Networking Basics

Network Bandwidth (Capacities)

Bandwidth is the amount of data that can be transmitted through the network (“data pipe”) • There are many pieces that make up the network. Generally, there is a PC, network connection, network wiring, network hardware (routers, switches) and if there is external communication, an ISP (internet service provider). • NOTE: throughput through the network is only as fast as the slowest segment because many factors effect the actual amount of data that can be carried.

Revision d1

Networking Basics

Network Bandwidth – Speed

Understanding the speeds of networking • Speeds are generally expressed in terms of millions of bits per second as megabit.

• Typical Ethernet networks are 100 megabits.

• Newer Ethernet networks are 1 gigabit and can carry 1,000,000,000 (billion) bits per second.

Revision d1

Networking Basics

Typical bandwidth usage by eMerge

• Network Controller to Expansion Node Programming = 1 megabit per second maximum • Network Controller to Expansion Node normal operation =25 kb per second maximum • Network Controller to computer =75 kb per second maximum

Networking Basics A typical bandwidth situation

The Internet comes in through a DSL or Cable connection Your Internet connection 325 kilobit outbound The outbound connection is only 325 kilobits second – per not so good for transmitting video 100 megabit symmetrical 1.5 megabit inbound Network The connection can supply data inbound at 1.5 megabits per second – good for surfing the web.

Your computer Another computer

Revision d1

Revision d1

Networking Basics TCP/IP Address information

TCP/IP Addressing, commonly referred to as IP Addressing is how devices known as Hosts (PC, Server, Router, eMerge) are identified on a Ethernet Network.

The components of IP Addressing;

MAC Address: this is a unique number set at the factory for each Ethernet device. The MAC Address cannot be defined by a user or Network Admin. It is hard coded.

IP Address: a unique 32-bit binary number that identifies the Host on a network.

Subnet Mask: a 32-bit binary number that identifies which portion of the IP Address is the Network ID and which is the Host ID.

Lab Exercise: View/Change IP address

Step 1:

To change the IP address of the PC we need to open the

Network Connections

menu in the Control Panel.

The Control Panel can be found in the Settings option of the Windows Start Menu.

Revision d1

Step 2:

Double Click on Network Connections

Revision d1

TCP/IP settings on PC

TCP/IP settings on PC

The Network Connections window contains defined network connections for this computer. You may have several, but we are only concerned with the Local Area Connection.

Step 3:

Double click on “Local Area Connection”.

Revision d1

Step 4:

• Select the Internet Protocol/(TCP/IP) adapter • Click Properties

TCP/IP settings on PC

Revision d1

Step 5:

• Set to Obtain an IP address automatically by default.

• Click on the radio button “Use the following IP address”

TCP/IP settings on PC

Revision d1

Step 6:

• Enter the IP address and Subnet Mask.

• Click OK The Internet Protocol (TCP/IP) Properties window will close.

TCP/IP settings on PC

Click on “OK” on the Local Area Connection window to finish.

Revision d1

Revision d1

TCP/IP settings on PC < End of Lab Exercise: View/Change IP address >

Revision d1

Networking Basics

What is a MAC Address?

A 12 digit hexadecimal number (shown in black) that uniquely identifies an Ethernet Appliance from all others.

24.122.43.21

02-32-30-00-BB-01 Ethernet A MAC Address is PERMENANT The MAC Address of an Ethernet device is programmed at the factory and is a unique number worldwide.

Workstation 1 192.168.0.20

00-21-3A-BF-CD-04 Workstation 2 192.168.0.21

00-21-45-2F-FD-08

Revision d1

Networking Basics

What is an IP Address?

• • • • An IP address is like your telephone number or your home address, each one is entirely unique. Every computer on the Internet has its very own IP address.

The standard format is four groups of numbers called octets that are separated by periods, and each number is an integer between 0 and 255.

For example, a typical IP address would look like this: 192.168.0.250

In order for two devices on the same network to communicate with each other, they must have the same first three octets (Network ID). In the example above, to communicate to that device, your PC must have the same first 3 octets and a unique 4 th octet [ 192.168.0

] .251

Revision d1

Networking Basics

In the diagram below there are 2 PCs on the same network segment. In this case the Network ID is composed of the first 3 octets of the IP Address.

02-32-30-00-BB-01 Ethernet Workstation 1 Workstation 2 192.168.0.20

00-21-3A-BF-CD-04 Network ID 192.168.0.21

00-21-45-2F-FD-08

Revision d1

Networking Basics

In the diagram below there are 2 PCs on the same network segment.

In this case the Host ID is composed of the last octet in the IP Address.

02-32-30-00-BB-01 Ethernet Workstation 1 Workstation 2 192.168.0.20

00-21-3A-BF-CD-04 192.168.0.21

00-21-45-2F-FD-08 Host ID

Networking Basics

IP Addresses come in “public” and “private” A public address is assigned by an Internet Service Provider (ISP) e.g. Verizon. This is the Internet connection for the facility.

24.122.43.21

02-32-30-00-BB-01 Ethernet A private address is local to the LAN or WAN of the facility and is determined by the DHCP server on the premises or the Network Administrator of the facility.

Workstation 1 192.168.0.20

00-21-3A-BF-CD-04 Workstation 2 192.168.0.21

00-21-45-2F-FD-08

Revision d1

Revision d1

Networking Basics

An IP Address may be

DYNAMIC

or

STATIC

A Dynamic IP Address is assigned automatically by the DHCP Server of the network. This IP Address can be setup to expire requiring the Host to get a new IP Address from the DHCP server. This method is used in both Public and Private networks.

A Static IP Address is assigned by the Network Administrator. The Network Administrator will actually type in the IP Address of the Host device and this IP Address will not expire or change by itself. Usually needed for key network devices such as routers, servers and printers. The eMerge Network Controller will require a Static IP Address.

Networking Basics

Ports and Port Usage

• Ports allow multiple data streams to go to a single address – Port numbers used by eMerge • 80 is the default for web servers using HTTP • 3306 is the default for database servers • 7262 is for Network Controller auto recognition of nodes – Routers can restrict which ports are available – You may need to have the network administrator unblock or allow access on port 7262 for eMerge communication.

www.mycompany.com

24.122.43.21

Ethernet

eMerge

192.168.0.20

Port 80 - web server Port 3306 - ODBC Port 23 - Telnet Port 7262 - eMerge Workstation 2 192.168.0.21

Revision d1

TCP Port 69 TCP Port 80 TCP Port 443

Networking Basics Network Port Usage

Must be open to the Network Controller for the on board TFTP Server to pass software upgrades to the eMerge Expansion Nodes. This port can be opened temporarily for updates and then closed again.

Must be open to the Network Controller for Browsers to access the eMerge User Interface. The eMerge User Interface may be configured to a different port if using 80 is not possible or desired.

Must be open to the Network Controller for Browsers to access the eMerge User Interface using HTTPS (SSL). This can also be configured to a different port if desired.

Revision d1

Networking Basics Network Port Usage

TCP Port 7262 Must be open to the Network Controller for communications between the Controller and the eMerge Expansion Nodes. Be sure that this port is open through routers and firewalls for any Nodes on different subnets from the Network Controller. (Communications between Controller and Nodes are authenticated and credential downloads are encrypted for security.

TCP Port 23 Must be open to the Network Controller using a jumper/wire harness plugged into the Controller for Telnet access

Revision d1

Network Attached Storage (NAS)

• • • An inexpensive way to share storage across networked systems.

Makes storage (hard disk or memory stick) available online.

– Unit at right costs less then $150 with internal storage.

eMerge can use NAS to to automatically store archived Activity Logs and store Database Backups. eMerge can also use an FTP Server for these features.

– Activity Logs are archived as CSV (comma separated value) files.

– Archived Logs cannot be accessed via the eMerge User Interface.

– Archived Logs can be viewed through a 3 rd party reporting software.

Revision d1

Networking Basics

Networking Basics Planning a network: Basic configuration - used if there is no pre-existing network

• • • • CAT-5 or greater will need to be used between router and PC & eMerge.

Determine an IP addressing scheme, ie. 192.168.0.XXX. Connect the eMerge Controller to the router.

Connect your computer to the router.

LAN side Router Laptop computer

Revision d1

Basic network connected to the public Internet Networking Basics

Internet • Same as previous system, but this time you can set: – – DNS server address(es) Gateway address – Network time server over the Internet – Cameras over the Internet * An ISP will be required.

LAN side Router Laptop computer

Revision d1

Networking Basics Corporate LAN with separate network for security devices

• This configuration isolates security equipment from the rest of the network.

– Need to exercise caution in assigning addresses.

– Note that the router at 192.168.0.24 creates the 192.168.1.x subnet.

– Need to open a port through the 192.168.0.24 router to permit HTTP traffic to the eMerge web server. Internet 24.11.223.62

Corporate LAN 192.168.0.x

Corporate PC 192.168.0.24

Security LAN 192.168.1.x

Corporate PC

Revision d1

Revision d1

This concludes the networking basics of eMerge Product Training & Certification

Browser Managed Security Platform

Hardware Architecture

Revision d1

System Overview

Hardware Architecture

Power Requirements

Panel and Circuit Board Layouts

Wiring Readers, Inputs and Outputs

System Architecture Overview

Photo ID Camera Photo ID Badge Printing

Security Administrator

IP Camera Portal Temp Probe Analog Camera Video Recorder

IP Network

Door Lock Reader Expansion Node

IP Network

IP Camera (PTZ) Temp Probe Portal Alarm

Security Monitor

Alarm Panel Portal Door Lock Reader

Revision d1

Expansion Node

Door Lock Reader

Controller & Node

Portal 6 5 4 3 2 1 Elevator Gate Reader

Internet Remote Support

Panel Led operation

If the cabinet contains a CONTROLLER/NODE COMBO BLADE the LED states are as follows

Green Steady Green Flashing Red Steady Network communication is functioning and external power is on.

Network communication is functioning and eMerge is using battery power.

Network communication is NOT functioning and external power is on.

Red Flashing Green Steady Network communication is NOT functioning and eMerge is using battery power.

If the cabinet contains a NODE ONLY COMBO BLADE the LED states are as follows

External Power is on.

OFF Battery power is on or the system has no power.

Revision d1

Power cable Ribbon cable Power Supply

Revision d1

Panel layout

Tamper Switch Controller & Node Combo Access Blade Input Blade Output Blade Temp Blade Blade Mounting Plate Cable Tie-down

Revision d1

Panel layout

Revision d1

Ribbon cable

Slot numbers are determined by the connector on the ribbon cable that is plugged into the module. The ribbon cable (see diagram below) is a bus and a module’s place on the bus determines the slot number. You will see that it is possible to place a module in physical slot 5 and yet attach ribbon cable connector 6 to the module. If this occurs the module will be in slot 6 on the bus.

Controller/Node connector Connectors for slots 1 2 3 4 5 6 7

Note: When connecting the modules to the ribbon cable be sure the connector is fully seated in the board

(push on cable do not rely on the tabs on the boards)

Revision d1

Power requirements

IEI eMerge systems must be AC powered using the grounded plug-in transformer provided. Power should come from a circuit with an isolated ground and must be wired to the power supply mounted inside the eMerge cabinet.

Transformer Input: 120 V AC 60 Hz 48W.

Transformer Output: 24V AC 50VA The IEI eMerge includes a DC power supply. The eMerge power supply provides 12V DC and is rated up to 5A.

The recommended battery which is not included - 12V DC, 7 AH, SLA (sealed

lead acid).

CAUTION!!! MAKE SURE ALL POWER IS OFF BEFORE CONNECTING OR DISCONNECTING MODULES IN THE IEI eMerge.

Revision d1

eMerge Hardware Architecture

The eMerge system is composed of a 3-tiered hardware architecture.

These tiers are named for the 3 components of the eMerge system.

These components are;

1.

Network Controller 2.

3.

Expansion Node Application Module

We will now examine each of these devices and their role in the eMerge system.

Revision d1

eMerge Hardware Architecture 1.

2.

3.

4.

5.

PC connects to controller via IP and user programs the controller through the UI Controller connects to Node via IP and downloads the programming done by the user on the controller to the node The node then operates any and all application modules connected via the ribbon cable Activity on application modules is detected by the node and the node reports the activity to the controller Controller reports activity to the user via IP to the PC through the UI, i.e. the activity log

Revision d1

eMerge Hardware Architecture

The eMerge Network Controller

The Network Controller is essentially a computer.

This computer has a LINUX based operating system embedded into the product. Also embedded into this product is; POSTGRE SQL Database Web Server Security Application Software

Revision d1

eMerge Hardware Architecture

The eMerge Network Controller

The Network Controller has a built in Network Interface with a 2 port switch. The Network Controller is ready to be deployed across an existing LAN or WAN. The Network Controller MUST be programmed with a Static IP address.

Static Address – This is a permanent address that has been allocated to the device by a Network Administrator.

The Network Controller is located on what is called the Combo Blade.

Revision d1

eMerge Hardware Architecture

The eMerge Network Controller

1. The Network Controller is the component that is programmed via a web browser.

2. The Network Controller supports the eMerge Expansion Node.

3. The Network Controller can support up to 32 Expansion Nodes.

Revision d1

eMerge Hardware Architecture

Combo Blade

The eMerge Network Controller same circuit board. and your 1st Node are located on the

Compact Flash Socket i-button socket

Bottom View

Network Controller Node I-button Socket I-Button The controller I-button comes pre installed.

If additional licensing/features are purchased the I-Button is upgraded remotely.

Hexadecimal number required to update licensing.

Revision d1

Controller LED’s LED 1 LED 2 NC to NN NC to NN Speed LED 4 LED 5 LED 6 NN Count N Com Blink System On Amber Connection Green Activity Node LED’s LED 7 Action on Module LED 8 Co-Processor LED 10 NN Com to NC LED 11 Power LED 12 NN to NC Speed LED 13 NN to NC Activity

Revision d1

eMerge Hardware Architecture

Combo Blade

Revision d1

eMerge Hardware Architecture

Node Blade

The Expansion Node allows the eMerge system as a whole to be “expanded” from 1-14 doors at a time per node.

The Node Only board is fitted with a single NETWORK PORT. Expansion Node only board

The eMerge EXN is an enclosure with an Expansion Node only board.

Revision d1

eMerge Hardware Architecture

Node Blade

The eMerge Expansion Node

1. The Expansion Node is the part of the eMerge system that directly connects to and supports the Application Modules (Blades).

2. Each Expansion Node can support up to 7 Application Modules.

3. Each Expansion Node is an Ethernet device which means that it has its own IP address.

eMerge Hardware Architecture

Node Blade

The eMerge Expansion Node

The Expansion Node has a built in Network Interface. The Expansion Node needs to be programmed with an IP address. This IP address may be Static, Dynamic or Network Controller provided.

Static

– This is a permanent address that has been allocated to the device by a Network Administrator.

Dynamic

– This is a temporary address that has been allocated to the device by the DHCP server of the network.

Network Controller Provided

– This is a permanent address that has been allocated to the device by the eMerge Network Controller.

Revision d1

Lab Exercise: Initializing eMerge A laptop running Windows XP Pro with IE – 6 or greater will be needed

• • • • Step 1: Setup Hardware – Power up the eMerge panel by connecting 3 conductor wire to the power supply and then to the plug-in transformer. Connect the transformer to the wall. Next connect the red & black braided wire harness to the NODE side of the Combo board. After 2-3 minutes you will hear a single beep indicating that eMerge is ready.

– Use a CAT5 patch cable to connect the PC to the 2-port switch located on the Combo board.

Step 2: Establish initial connection to eMerge – Set the laptop to a static IP address of 192.168.0.249 using the TCP/IP adapter.

– Launch a browser window on the laptop and connect to emerge by typing in address http://192.168.0.250. This is the default IP address for eMerge from the factory. You should be connected to the Initmode screen.

Step 3: Turn off Initmode – – – – – In the Time Settings section, enter the current date and time and time zone.

In the Initmode Settings section, change the drop down menu to NO.

Click Save.

Once the Data saved message appears, scroll to the bottom and click the Reboot button.

eMerge will beep twice to indicate the Shut Down process has begun, then after the reboot has completed wait for the single beep to acknowledge System Ready.

Step 4: Login – Connect to emerge by typing in address http://192.168.0.250 into your browser window.

– Login using: User Name= admin, Password= admin.

Revision d1

The Initmode page is where the basic settings for eMerge are maintained. The controller IP address, controller date & time, email server settings and the web server port.

Initmode

Revision d1

Revision d1

eMerge Hardware Architecture

There are 4 eMerge Application Modules/Blades currently available

Access Control Module (eMergeACM) The eMerge will refer to this unit as an ACCESS BLADE Input Module (eMergeINP) The eMerge will refer to this unit as INPUT BLADE Output Module (eMergeOUT) The eMerge will refer to this unit as OUTPUT BLADE Temp Module (eMergeTMP) The eMerge will refer to this unit as TEPERATURE BLADE

Revision d1

Portal

Access Control Module (ACM Blade) ACM Blade Lock (output)

Access Control Module (ACM Blade)

An ACM blade is capable of handling two doors, or one door with two readers • • • Two Wiegand reader connectors – Readers using standard Wiegand output up to 128 bits are supported.

Four Supervised Inputs – – Door contacts and REX devices.

Standard two wire inputs.

– Wide variety of input supervision types.

Four Form C Relay Outputs – Lock output, door opener, buzzer.

– Standard 3 pin normally open or normally closed dry contact.

2 Wiegand Readers NOTE: Inputs and Outputs not used for door hardware can be used for other functions.

Revision d1

Wiring Wiegand Readers

Reader Ports are only found on the Access Control Module (ACM) Front End Reader Terminal Blocks Access Control Module

CAUTION!!!

readers.

Each eMerge Access module can supply 12VDC@200 milliamps of power per reader. If the reader(s) connected to the ACM Blade draw more than 400 milliamps combined, then an external power source must be supplied to these

Revision d1

Wiring Wiegand Readers

Wiring Wiegand readers to the Access Control Module (ACM) Pin-out of Front End Terminal Block +12VDC (red) -12VDC (black) D0 (green) RED led D1 (white) BPR control GRN led

Twisted, shielded, 22 gauge cable is required with a maximum run of 500 feet

Revision d1

Input Module (Blade)

• • 8 standard two wire inputs – Used to monitor door position, REX, etc… Supervision Types – Dual Resistor NO or NC – • Four States: Normal, Alarm, Short, Open Parallel Resistor NO or NC – – • Three States: Normal, Alarm, Open/Short Series Resistor NO or NC • Three States: Normal, Alarm, Open/Short Unsupervised NO or NC • Two States: Normal, Alarm Note: Twisted, shielded, 22 gauge gives you a maximum run of 2000 feet and 1K ohm resistor is used for supervision

Revision d1

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm Short Open

Resistance Values

1k Ohms 0.5k Ohms or 2k Ohms 0 Ohms No Current

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm Open

Resistance Values

0 Ohms 1k Ohms No Current

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm Short

Resistance Values

1k Ohms No Current 0 Ohms

Supervision Types

Revision d1

Input State

Normal Alarm

Resistance Values

0 Ohms No Current

Input Blade

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm Open

Resistance Values

1k Ohms 0 Ohms No Current

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm Short

Resistance Values

No Current 1 Ohms 0 Ohms

Input Blade

Supervision Types

Revision d1

Input State

Normal Alarm

Resistance Values

No Current 0 Ohms

• 8 Standard two wire inputs.

• eMerge Temperature Monitoring probe (eMergeTMPPB) • Temperature blade barcode numerals begin with “08.”

Temperature Module (Blade)

Revision d1

Output Module (Blade)

Eight 3-pin SPDT dry contact output relays – – – Standard normally open or normally closed Form C Relays Suitable for controlling many strikes, but a step up relay should be used for magnetic locks.

Requires appropriate suppression: MOVs or diodes Output devices: Strikes, Mag locks, door closers, sounders, etc…

Revision d1

Revision d1

Wiring Outputs

Pin-out of 3-pin Output Terminal Blocks Relay schematically 3-pin Output Terminal Block Normally Open (NO) Common (C) Normally Closed (NC) The outputs of the eMerge application modules are form C dry contact relays

Revision d1

Normally Not Energized

Output Relay Connectors Output States

Normally Energized

1.

2.

3.

4.

5.

Installing a blade

Power down the eMerge.

Thread the standoff tube provided down onto the threaded post on the chassis next to the slot where you will insert the additional module.

Be sure that you are grounded and insert the additional module into the slot on the chassis with the ribbon cable connector toward the left of the eMerge cabinet. See diagram below.

Place the lock washer provided over the top of the standoff and thread the screw provided through the flange and down into the top of the standoff and snugly down onto the lock washer. See diagram below.

Connect the ribbon cable from the Controller/Node module in the topmost slot to the newly installed module. The connector is polarized. Make sure that the center bump fits into the opening for it on the connector on the module. Press the connector firmly into place until you hear the click of the extraction levers snapping into vertical position. You may have to press the extraction levers into full vertical position before you will hear the click.

Board goes down into slot lock washer Standoff comes flush to flange standoff tube

Revision d1

Power supply input 2-pin Battery input 3-pin The power supply is pre wired to the network controller. pin 1 +12V DC pin 2 ground pin 3 pin 1 +12V DC ground Wiring battery and power to controller Processor

Note: Do Not connect Battery to power supply board. Connect to the controller board

Revision d1

Portals are an access or an egress point. They can be a door, gate, turnstile, locker, etc… It combines all the inputs and outputs associated with granting access or locking the access point. All of the readers, inputs and outputs must be created before they can be added or referenced in a portal.

Revision d1

The Portal

Lab Exercise: Enable valid access of a card holder

• • •

Step 1: Connect the Reader

– Connect the reader to the ACM blade into reader position #1. Depending on the type of reader, you may or may not need to connect the red led wire.

Step 2: Setup a Reader

– – – – Select Setup : Site Settings : Network Nodes On the Blades tab, click the Access Blade link.

In the picture of the Access Blade, click the icon for the 7-pin reader connector in Position 1.

In the popup Reader/Keypads window complete the following fields: • • • • • Name: Main Lobby Reader Enabled: place a check Network Node: select “Training Node” Reader/Keypad Type: “Wiegand Card Reader” Click Save

Step 3: Setup a Door Lock

– On the picture of the Access Blade, click the icon for the 3-pin outputs Position 1.

– In the popup window complete the following fields: • • • • • Name: “Front Door Lock” Enabled: place a check Network Node: select “Training Node” Default State Code: “Not Energized” Click Save

Revision d1

Step 4: Define a Portal

– Select Setup : Access Control : Portals – Enter the following information: • • • • • Name: Main Lobby Portal Network Node: select “Training Node” In the Unlock/Request-to-Exit (REX) section – Lock: Main Lobby Lock In the Card Readers/Keypads section – Reader 1: Main Lobby reader Click Save

Revision d1

Step 5: Define Credential Format

• • Select Setup : Access Control : Card/Keypad Formats Select the “26 bit Wiegand” record (it should at the top of the list); click the rename link under the Name field and change the name to “Wiegand 26 FC 11”.

• • • Make sure the Bit Length is “26” Make sure the Facility Code is “11” Click Save

Revision d1

Step 6: Setup an Access Level

• • Select Setup : Access Control : Access Levels Complete the following fields: – – – – Name: “General Access Level” Enabled: Place a check Readers: “Individual” / “Main Lobby Reader” Time Spec: “Always” • Click Save

Revision d1

Step 7: Add a Person

– Select Administration : People : Add – Enter your last and first name in the name fields – Click the Next button

Revision d1

• • •

Step 8: Assign a Card

– In the Access Control

Format

tab insure that “” is selected in the Access Cards list box and the Card is “Wiegand 26 FC 11”.

– – – Click the Read Card button.

Click the Go button in the popup window and the prompt “waiting for card read: xx seconds” will appear.

Pass a credential over the reader and it should read it and fill in the Hot Stamp # and Encoded # fields.

Step 9: Assign an Access Level

– In the Access Levels section move the “General Access Level” from the Available to the Selected list.

– Click Save.

Step 10: Test Access

– Select Monitor : Activity Log – Pass the credential you assigned over the reader.

– The Reader LED should turn green momentarily and you should hear an output relay click indicating that the lock output has operated successfully.

– The Activity Log should show that access has been granted for that person.

Revision d1

Database (System) Backups

Revision d1

The database configuration of your eMerge should be backed up if you make changes to the setup, add or change personnel security records, apply a software service pack or upgrade your software level. As of version 3.0 any configuration changes and person records saved are written to ROM as well as RAM. So if you loose power you do not loose any changes since the last backup.

NOTE: Backups remain on the compact flash until they are deleted.

Revision d1

Email Address

eMerge may be configured to send email notifications of alert conditions. The Email Server used to send email indentified here should be set up by the network administrator so it will recognize the Network Controller’s email address.

Setting a Threat Level

Threat Levels may be activated either by accessing the Set Threat Level page and selecting the desired threat level or by creating an event action that sets the threat level. Threat level ranges may be setup in Threat Level Groups and may be used to increase access requirements. This may be done by assigning a Threat Level to Portals and Access Levels.

Revision d1

Revision d1

End of eMerge Product Training & Certification