Click to add title

Download Report

Transcript Click to add title

Power RICH System Enterprise Edition
Click to add subtitle
Gil Blackburn BCI Technologies &
Dr. Jay Park Product Manager
Power RICH System Enterprise Edition
The Power RICH System is really 5 Products
tightly Integrated in to 1
1. Triple Redundant SCADA System
2. Historian
3. Advanced Alarm Notification
4. Integrated Web-server
5. Relational Database Server - SQL
Power RICH System Enterprise Edition
Features
•
The Power RICH System© is an Object-Oriented Power Monitor and Control System with pre-build libraries of power
devices (IEDs)
•
Mirrored Triple Redundancy
•
Integrated Development Environment (IDE)
–
Allows multiple engineers to work at the same time – Online changes without compiling
•
Scalable Object-Oriented Architecture provides incremental expansion
•
Built-in Report Generation - Uses industry standard Crystal Reports Runtime
•
Alarm Redirection - allows for advanced alarm management (Email, Text Messaging, Severity Level Changes)
•
Built-in Historian
–
–
–
•
All data is time-stamped with 100ns of resolution and Stored based on change and or time
Years of online data available - the storage capacity only limited by disc-space
Historian files are easily archived and restored
Connectivity to other systems
–
ODBC, OPC, SQL allows bidirectional access to other systems.
•
Optional built-in Web Server - does not require Microsoft IIS for Web Clients
•
Based on Open Standards - protects the customers investment
–
–
–
–
Standard protocols, OPC, OLE/DB, ODBC, HTTP, XML, DNP3 & Modbus
Multiple Comm links supported, including serial, LAN/WAN, radio and PSTN
Component-Object architecture allows reusable application objects–PRS Devices
Configured at object level & based on user-access levels and object permissions
Power RICH System Enterprise Edition
SCADA Lifecycle
Design
Architecture
Scalability
Redundancy
Communications
Licensing
Features
Build
Online
Integrated Dev
Environment
Object Oriented
Operate
Vector Graphics
Expansion
Navigation
Management
Alarm
Management
Diagnostics
Embedded Obj
Data Quality
Advanced Tools
Maintain
Trend-Historian
Reports
Security
Ad-hoc
Reporting
Power RICH System Enterprise Edition
Architecture
• Power RICH System© is a 3rd generation SCADA
product that offers true state-of-the-art client / server
architecture with an on-line object orientated
database
• Ideally suited for wide area network applications
normally found in utility markets
• Based on open standards for networking,
communications and interaction to 3rd party
applications. OPC, ODBC, SQL,DNP3, IEC,
Modbus
Power RICH System Enterprise Edition
Architecture - continued
Power RICH System Enterprise Edition
Scalability - SCADA
• System can start small with a single PC and is
easily expanded without programming or reengineering for larger system requirements.
View X Clients
Local Area Network
Mirrored Redundant
SCADA Servers
Master SCADA
Server
2nd Standby Redundant
SCADA Server
Triple Redundancy
Power RICH System Enterprise Edition
Reliability - SCADA
•
•
•
•
•
•
•
Power RICH System© offers High System Reliability which is achieved through:
1. Redundant Clients
2. Redundant LAN and communication links
3. Dual, triple or even quad mirrored redundant servers
4. All Real-time data, Configuration, Communications, History, Alarms, Events, and
Reports are Mirrored on all Redundant Servers
Online Changes with no compiling means never having to shutdown the system
Home Office
5. NO PROGRAMMING REQUIRED!
ViewX Clients
ViewX Clients
Redundant LANs
All information is Mirrored on
all servers Automatically
Redundant
Communications
Paths
Wide Area
Network
Triple
Redundant
Servers
Standby
Redundant
Server
Performance
(Proxy) Server
Power RICH System Enterprise Edition
Clustered Architecture
Power RICH System
ViewX Client
Power RICH System
ViewX Client
Power RICH System
ViewX Client
...........
Power RICH System
Triple Redundant
Server Cluster
Power RICH System
Triple Redundant
Server Cluster
Power RICH System
Triple Redundant
Server Cluster
Up to 64 Server Clusters Viewed as One
Integrated System
Power RICH System Enterprise Edition
Communications
• Power RICH System© is optimized for Wide Area RTU /
IED communication architectures.
• Advanced communication driver architecture supports:
– Serial and TCP/IP communications
– Serial connections via remote ports including network terminal
servers
– Native PSTN dial-in and dial-out capability
– Modem pool operation and management
– Integrated network LAN / WAN operation for RTUs
– PSTN backup for serial and network connected RTUs
• Native backfilling of time-stamped data into Power RICH
System© History and Event Journal databases, and Alarm
sub-systems
• Built-in communication statistics for channels and RTUs
• No programming (Code) required
Power RICH System Enterprise Edition
Server Licensing
Servers are point based, ranging from small to large;
– 500, 1500, 5k, 25k, 50k+
– Server includes integral ViewX license
– Redundancy and standard drivers are included
• DNP3.0 Master & Slave,
• IEC61870 101 & 104,
• Modbus Master & Slave
– WEB Server is optional
– Points includes metadata depending on protocol
• What is the difference between a Point and Tag?
• A tag generally refers to a single I/O reference or register in
an external Device or RTU, whereas a point includes other
property attributes like time-stamp, data quality flag,
previous value, alarm limits etc
Power RICH System Enterprise Edition
Client Licensing
ViewX -Full function Windows client. No point count limits!
• Used for Operator station and Development
•
•
•
•
– Any ViewX client can be used for system development provided user
has security permissions
Alarm banner and audible alarms
All graphics are vector based - resizable to any windows resolution
– Vector graphic displays are small in file size compared to bitmap
therefore high performance over WANs
Support for multi-head displays (several monitors under Windows)
Single ViewX license connects to 64 Power RICH System servers
simultaneously ('clustering')
- Zero administration client, no database or graphics to install
WebX - Zero configuration thin Web clien
- No WEB Server to install or manage – it is built in the system
- Full monitor and control capabilities as per security configuration
- No development supported
Power RICH System Enterprise Edition
Integrated Development Environment
• Power RICH System
uses a single "ViewX"
used to configure and control the SCADA system.
Providing both operators and engineers use the
application to both control and monitor/configure
based on security settings simultaneously
- Single point of configuration for whole system
- On-line development - NO COMPILING or shutting
down
•
SCADA database is object oriented and this
saves 75-90% development effort over
traditional systems.
•
Change in thinking, you start configuration by
mimicking physical assets and operational areas
rather than tags and displays.
•
In example shown, we create folders and hierarchy
based on customer's business. Folder colors show
templates and instances
Power RICH System Enterprise Edition
Object Oriented
• Common devices can be
represented as a template, then
'instances' provide rapid
deployment for system
•
Any Power RICH System
object can be included in a template,
so this is much more than graphics
and tags
•
Templates can be nested ie.
'PumpStation' template can include 2
individual 'Pump' templates
•
Changes to templates are
automatically reflected in all
instances. There is provision for
object property override to allow
individual settings i.e. alarm limits, or
controller station address to be
different per instance
Power RICH System Enterprise Edition
Embedded Objects
•
Embedding objects is another time saving tool for rapid system
deployment.
•
In Power RICH System you can embed graphics, trends, lists, html
pages and live video.
Power RICH System Enterprise Edition
Data Quality
•
The Power RICH System server keeps an image of all the SCADA points in its real-time
database. It is important to understand what is included in a point object as this
metadata is more than just a tag. Attributes such as value, data quality, alarm limits,
over range indication, data time-stamp, previous values & point statistics are
managed at the point level.
Power RICH System Enterprise Edition
Vector Graphics
•
Power RICH System native graphics are vector based, this provides scalable displays
without pixilation, typical 1/20 size of bitmap graphics, suitable for any windows
resolution and performance over WAN links
•
800x600 for field laptop and 1680x1050 for control room - no modifying displays
•
Pan & Zoom for map based displays and layer support for de-clutter
•
Graphic displays are stored in Power RICH System server only, no maintenance on
client workstations.
Can import .DXF, .EMF and .SVG graphics formats
•
Desktop Display 1280 x 1024
Control Room Multi-Head 21”
Displays 2048 x 1536
Power RICH System
EE Server
Field Laptop 800 x 600
Vector based Graphics are Scaled by Client
Power RICH System Enterprise Edition
Navigation
• Power RICH System
has several options available
for navigation of project:
– 1. Create hyperlink (button) to open objects such as graphic
pages, trends, alarms, lists and reports
– 2. Use the built-in database hierarchy to select objects
– 3. Use built-in context sensitive menu available on most objects
i.e. ACK alarms, display events, view notes etc.
– 4. Create user configured menu that may be embedded on page
template
Power RICH System Enterprise Edition
Alarm Management
• Alarms are configured as attributes on any point object
– This means you do not need to configure additional tags for alarms
•
Alarm filtering, suppression and redirection are standard features & no code required
•
Send Text Messages or Email based on Alarm conditions. Acknowledge
alarms by replying to email
•
Filter by device, folder, area, user, time range, severity level, state etc.
•
Suppress for fixed, variable time or logic condition
•
Up to 1000 severity levels
•
Power RICH System has a standard alarm banner & built-in alarm page
Power RICH System Enterprise Edition
Alarm Redirection
• Alarm redirection supports business rules to
ensure the right user(s) are alerted at the right
time when critical events occur in the system.
• The trigger condition is generally an alarm;
either individual, group or severity level, and if
after a predefined time delay when the condition
has not cleared or acknowledged, a notification
will be sent to the user via email, pager or voice.
Power RICH System Enterprise Edition
Alarm Redirection - continued
Power RICH System Enterprise Edition
Trend - Historian
• Trend Types
– Current Trend
• Available on any point and does not need to be
preconfigured
– Raw Historic
• Point is configured for archive and stored in Power
RICH System historian
– Processed Historic
• Advanced analysis such as min, max and average
over user configured time range
Power RICH System Enterprise Edition
Trend – Historian continued
• Trend Displays
– Pre-Built
• Pre-built display available on any point without
configuration
Power RICH System Enterprise Edition
Trend – Historian continued
• Trend Displays
– Trend Object
• Trend that is pre-configured with pens, display options either
full page or embedded
Power RICH System Enterprise Edition
Trend – Historian continued
• Trend Displays
– Pre-Built
• Pre-built display available on any point without configuration
– Trend Object
• Trend that is pre-configured with pens, display options either
full page or embedded
– Operator Store
• This uses document store to allow operators to create ad-hoc
trends
– XY Plot
• View 2 points against each other i.e. pressure vs flow for
pump curve
Power RICH System Enterprise Edition
Reports
• Report templates are developed using industry
standard 'Crystal Reports'.
• Report development and viewing is directly
embedded in the ViewX client.
• Report templates and generated reports are
managed by Power RICH System Server
• Inherent report redundancy, management of
historic Reports
• Multiple report formats, multiple export targets.
Email, PDF, HTML, Excel, CSV, SQL Export.
• Generate reports on schedules, ad-hoc,
automatically on exception
Power RICH System Enterprise Edition
Security
• Power RICH System
•
•
•
security is granular down to object level
User management is through individual user accounts and groups
Security policy includes minimum password length, aging, dictionary
and inactivity logout. Full audit trail on all actions
Single sign on for clustered systems, all interfaces are secure: Web,
OPC, ODBC & OLE Automation
Power RICH System Enterprise Edition
Expansion
•
Object-based templates offer a significant time saving in configuration when
you need to expand your system. Simple drag and drop means that you
replicate devices, groups or even entire sites within minutes.
•
Adding additional Power RICH System Servers or Clients is simple, 'click
in box' without any reconfiguration of the system
• Database expansion
- full on-line configuration
- increase points, upgrade server size if necessary
• Add server(s)
- as mirrored server for complete system
- as performance server for local users
• Add clients
- ViewX for operators or additional development PC
- WebX for remote access
• Add systems
- ViewX can cluster to multiple servers without any configuration
- server can be deployed as test system with drag and drop configuration
Power RICH System Enterprise Edition
Management
• Power RICH System includes software tools to
remotely manage the Power RICH System
• For the customer project, ViewX can do all configuration
remote from Server including across WAN.
• For Power RICH System Server setup and monitoring,
two applications are available: Server Status and WebX
client
• All access complies with preconfigured security
permissions
Power RICH System Enterprise Edition
Management
Power RICH System Enterprise Edition
Diagnostics
• Power RICH System has a number of built-in drivers to self monitor
critical areas:
•
1. Exposes
server status as OPC points
•
2. PRS-EE protocol drivers include statistics and 'live diagnostics' via telnet session
•
3. 'Performance
•
4. SNMP
Monitor' driver for accessing operating system components
such as CPU memory, disk space, network traffic etc.
and ICMP drivers are integrated for monitoring network
devices such as UPS, LAN switches and even 'pinging' ViewX clients.
Power RICH System Enterprise Edition
Ad-hoc Reporting
• PRS-EE includes an easy-to-use ad-hoc query tool to access all
internal database tables for analysis and reports.
• The resulting dataset is displayed as a list and this list is updated
dynamically
• The list can be filtered (F7 key) and you can copy the underlying
SQL query to an embedded list if you wish to view often
Power RICH System Enterprise Edition
Questions?
Power RICH System©
Enterprise Edition
A Data Solution
Provider
Power RICH System Enterprise Edition
Thank you for your time.
CREC