SRON presentation - University of Groningen
Download
Report
Transcript SRON presentation - University of Groningen
Basic Detection Techniques
Front-end Detectors for the Submm
Andrey Baryshev
Lecture on 21 Sept 2006
Outline
•
•
•
•
•
Stability measurements of practical receiver system, Allan
variance plot, calibration intervals
Direct detectors (principle)
• Photo-detectors
• Bolometers
• Other types (pyro-detectors, Golay cell)
Noise in direct detectors
• NEP -- noise equivalent power
• Photon noise
• Electronics noise
Low noise detectors in submm THz region
• Transition edge sensors
• Kinetic inductance detectors
• SIS junction as direct detector
Practical measurement of NEP
Basic Detection Techniques – Submm receivers (Part 3)
2
Practical receiver at a telescope/or any lab
Front-end
Calibrator
Thot
Tcold
Telescope
a
Receiver
Back-end
Tsys, Gsys
Tsky(t)
Source spectrum
1 - bin
100 K
f
Signal amplitude = 1 K on top of 100 K background
Spectrometer bin bandwidth = 1 MHz, Tsys = 100 K
What to do to detect
with accuracy 5 σ (S/N=5)?
Basic Detection Techniques – Submm receivers (Part 3)
3
Integrate (wait)! How long?
Uncertainty dT
dT =
τ=
Tsky
τB
Tsky2
dT2 B
Radiometer equation
NOTE: Tsky = Tbkg+Tsys = 200 K,
201 K for the line! Not Tsys!
dT = 1 K / 5 (S/N) = 0.25 K
Ideally after continuous integration of 0.64 s
accuracy is achieved!
Basic Detection Techniques – Submm receivers (Part 3)
4
Why radiometer equation?
20
15
Fourier ->
transform
10
5
0
0
5
10
time
15
Photon Count pcs df
Photon Count pcs
Fundamental noise is photons -> statistics is “white” noise:
uniform spectral density
20
15
10
5
0
2
4
6 8 10 12 14
frequency
White photon noise statistics results in radiometer equation
Basic Detection Techniques – Submm receivers (Part 3)
5
Real life receivers
Real
20
20
15
15
10
10
s
s
Ideal
5
5
0
0
2000
4000
6000
8000
10 000
0
0
2000
4000
t
6000
8000
10 000
t
System instability:
Standing waves, drift, 1/f noise, ambient temperature,
Atmosphere, many more …
How often do we need to calibrate (loose time)?
Basic Detection Techniques – Submm receivers (Part 3)
6
Allan variance
Measurement sequence with minimum integration time tmin
s1,s2 … sn … sN
σ(t)2 =
s1
2t
4t
1
<(yn+1-yn)2> where yn is the average of subset of
2
sn over integration time t
s2
s3
y1
s4
y2
y1
s5
s6
s7
y3
s8
y4
y2
s9
s10 s11 s12 s13 s14 s15 s16
y5
y6
y3
y7
y8
y4
…
Basic Detection Techniques – Submm receivers (Part 3)
7
Allan time
0.50
real
sigma
0.30
0.20
0.15
ideal
0.10
2
5
10
20
50
100
200
t
Maximum integration time between recalibrations
Basic Detection Techniques – Submm receivers (Part 3)
8
Direct detector principles
Direct detector gives signal proportional to the power of incoming
radiation or amount of photons.
Usually detector pixel is much simpler than heterodyne
counterpart, so large arrays are possible
•
•
•
•
Photo detector (electronic)
Bolometric principle (Thermal detectors)
Coherent detectors (diode)
Other principles
Basic Detection Techniques – Submm receivers (Part 3)
9
Parameters of direct detectors
•
•
•
•
•
•
•
•
Quantum efficiency
Noise
Linearity
Dynamic range
Number and size of pixels
Time response
Spectral response
Spectral bandwidth
Basic Detection Techniques – Submm receivers (Part 3)
10
NEP
NEP is input power at the input of the detector to produce
SNR=1
One can add the contributions of different noise sources
in square fascion as in the formula ebove for optics noise
contribution
Basic Detection Techniques – Submm receivers (Part 3)
11
Photon noise and Johnson noise
Detector is limited by statistics of incoming photons
NEP =
2hc(1/t)1/2
λ η1/2
Detector is limited by Johnson noise (thermal fluctuations)
NEP =
2hc(kT)1/2
ηλqGR1/2
Basic Detection Techniques – Submm receivers (Part 3)
12
Black body facts
Uncertainty in
photon numbers
Photon occupation numbers
Photon NEP
Φ = 4 π R2 L
M = σT4
L= e (2 h f3)/(c/n)2 /(Exp(hf/(kT))-1)
Stefan-Boltzmann law
Basic Detection Techniques – Submm receivers (Part 3)
13
Photo detectors
Arriving photon generate/modify free charge
carriers distribution
•
•
•
Classical semiconductor (utilizing band gap)
• It has a lower frequency limit hF > Egap
• Typical semiconductor work in IR region
• By applying stress to the crystal, it is
possible to decrease Egap Like in stressed
germanium
SIS junction
• No low frequency limit (effective band gap
modified by bias point)
• High frequency limit due to gap structure
Kinetic inductance detectors
• Photons break Cupper pairs
• It has low frequency limit
E
hF > Egap
Basic Detection Techniques – Submm receivers (Part 3)
14
Example
Detectors PACS instrument on Herschel,
Stressed germanium
Basic Detection Techniques – Submm receivers (Part 3)
15
KID arrays for Astronomy
Principle of Kinetic Inductance Detection
Antenna
Pair breaking detector
•
•
•
Superconductor ~ LKIN at T<Tc/3
LKIN ~ Nqp ~ power absorbed
Use LKIN to measure absorbed power
1
KID
a SC material in resonance circuit
•
•
•
2
CPW ¼ Resonator
L= 5 mm @ 6 GHz
read out at F0 ~ 4 GHz
resonance feature is function of Nqp
signal in S21 or R and θ
Im R
S21 [dB]
Al ground plane
Re
f
F0
100 m
CPW Through line
F [Ghz]
1
Readout signal ~GHz
substrate
Coupler
Central conductor
Basic Detection Techniques – Submm receivers (Part 3)
2
16
KID arrays
KID radiation coupling
Antenna
Antenna in focus of Si lens
1
Herschell band 5 & 6
2
Radiation from sky FRF >>2Δ/h
Most sensitive area
-> increases Nqp
-> change in S21 or R and θ
CPW ¼ Resonator
L= 5 mm @ 6 GHz
F0 << FRF
antenna << resonator
F0 << 2Δ/h
No qp creation due to readout
Si Lens
Al ground plane
100 m
Radiation
CPW Through line
1
Readout signal ~GHz
substrate
Coupler
Central conductor
Basic Detection Techniques – Submm receivers (Part 3)
2
17
KID arrays
Principle of KID arrays
•
•
Resonances @ F0
F0 set by geometry (length)
Intrinsic FDM
no light
LED on
-15
-20
S21 [dB]
•
-25
-30
-35
4.056
4.058
4.060
4.062
4.064
4.066
4.068
F [GHz]
Basic Detection Techniques – Submm receivers (Part 3)
18
KID arrays for astronomy
General idea for the FP
•
Optical Interface
flies eye array of Si lenses, size 20Fλ/2.
90.6% packing efficiency in hexoganal
•
Array
Detectors printed on back Si lens array
•
Readout
4 SMA coax connectors
2 full chains -> redundancy
~5000 pixel
0.48 mm
Basic Detection Techniques – Submm receivers (Part 3)
19
KID focal plane for NIKA
400 pixel test array for 2 mm
antenna
KID
Through line
Basic Detection Techniques – Submm receivers (Part 3)
20
Pair breaking detector: fundamental sensitivity limit
# quasiparticles
DOS
NEP 2 N (T) / (T)
quasiparticle lifetime
NEP [W/Hz]
NEP
1E-13 Nqp
N0
~ 2
T exp
0
k
T
B
e-p coupling
Pmax/NEP>10.000
10
10
1E-14
10
1E-15
10
1E-16
10
1E-17
10
1E-18
10
1E-19
10
1E-20
10
1E-21
10
9
8
7
6
5
4
1 sec
[nsec] or Nqp
0
3
2
1
1E-22
10
0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50
T/Tc
Basic Detection Techniques – Submm receivers (Part 3)
21
Measuring Dark NEP
Noise
•
•
•
•
•
•
Signal
qp x
NEP S x ()
N
qp
Measure bare resonators
Measure all ingredienst of NEP
Quasiparticle lifetime qp
noise
Sx
Quasiparticle response δx/δNqp
For R and θ
θ or R
1
1 2 2 qp
Im R
Re
Cryostat
qp roll-off
Shorted end
Synthesizer
Superconductor
~
1
Open end,
coupler
Quadrature
mixer
Re
2
ADC
IQ
LNA
analyses
Im
Basic Detection Techniques – Submm receivers (Part 3)
22
Quantum type detector with superconductor
・High sensitive in far-IR – sub-mm region
SIS junction
Bias voltage, V
Superconductor
Superconductor
photon
q
S
[A/W]
h
N 2qI sg [A/ Hz ]
Insulator
E
Density of states
qV
h qV 2
EF
Δ
q: elementary charge
h:plank constant
ν:frequency
Isg: subgap current
η: quantum efficiency
N h 2 I sg
NEP
[W/ Hz ]
S
q
Current status: 10-16 ~10-17 W/√Hz
Our goal:
NEP 10 19 W/ Hz @ 600 GHz
for I sg 10 fA, 0.5
Basic Detection Techniques – Submm receivers (Part 3)
23
23
D(E):density of states, F(E): Fermi function, Δ: gap energy
Tinkham (1975
Current [ A ]
Nb/Al-AlN/Nb junction
7/17/2015
4.2 K
1.6 K
Theoretical curves
?
Bias
voltage [ V ]
Basic Detection Techniques – Submm receivers (Part 3)
24
24
Transition edge sensor principle
Thin superconducting film as
thermometer
Square law power detector
thermal time constant t = C/G
C: thermal capacitance
G: thermal conductivity
Basic Detection Techniques – Submm receivers (Part 3)
25
Procedure of an NEP measurement
•
•
•
Determine the signal power
• It is given by Planck formula
• Need temperature of calibrator black-bodies
• Frequency coverage of the detector (measured by FTS)
• Knowledge of solid angle of antenna beam pattern
Determine the responsively
• Measure response from hot/cold radiators
• Calibrate detector output in input power units
Determine the background noise
• Block connect the detector beam to as little background –
possible
• Measure time trace and using responsively and integration
time express it in NEP Wt/Hz1/2
Basic Detection Techniques – Submm receivers (Part 3)
26