McDonald’s Heated Landing Zone

Download Report

Transcript McDonald’s Heated Landing Zone

McDonald’s Heated Landing Zone

The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Five screws on the bottom of the unit secure the controller tower.

Nuts holding the air tower diffuser in place should be loosened, not removed when dismantling the unit.

The sealant on the seam of the heater plate must be cut prior to prying the plate off of its adhesive backing.

Remove the plate when the unit is hot; the adhesive will be more pliable.

Air RTD Air Thermocouple Fuses Relays

Blower Assembly

Air Heater

Check temp. of heater plate / adjust setpoint Check temp. of air heater / adjust setpoint ON/OFF Adjust setpoint Programming switch

The setpoint for the plate and the air heater can be changed :

With the unit off, press the Check button and then buttons marked 1,2,3,3 in that sequence

.

SET will be displayed.

Press 1 to adjust heater plate; press 4 to adjust air temp.

Use UP (2) and DOWN (3) arrow keys to adjust setpoint.

Press Check to lock in changes.

The reliability of the HLZ’s temperature readouts can be checked. Test ports are positioned on the unit’s front panel, which allow independent measurement of the heater plate and air heater’s temperature. A variance of

±

5 0 F between readout and meter is acceptable.

HLZ Wiring Diagram COMPUTER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WHT RED BRN RED AIR RTD PLATE RTD 12V LOAD COM 208/240V

240V OPTION (CAP UNUSED WIRE W/MALE PUSH-ON) AIR HEATER PLATE HEATER

BLOWER GRN

208V OPTION

WHT BLK

AIR HEAT RELAY

+ +

PLATE RELAY FUSE BLOCK WHT BLK GRN/Y POWER CORD

PLATE THERMOCOUPLE (TYPE K) AIR THERMOCOUPLE (TYPE K) TOP TEST PLUGS BOTTOM RED WIRE NEGATIVE

LATCH RELAY HYPOT TEST POINT

0