Transcript Introduction of RoHS
Introduction of RoHS
- RoHS and Measurement Techniques Shimadzu Corporation
Spectro Business Unit
1/8
RoHS
(Restriction of the use of certain Hazardous
Substances in electrical and electronic equipment)
issued on February 13th in 2003
Objectives
The purpose of this Directive is to approximate the laws of the Member
States on the restriction of the use of hazardous substances in electrical
and electronic equipment and to contribute to the protection of human
health and the environmentally sound recovery and disposal of waste
electrical and electronic equipment.
The use of hazardous substances such as Pb, Hg, Cd, Cr(VI) and
brominated flame retardant (PBB and PBDE) in electrical and
electronic equipment is restricted until July 1st 2003.
2/8
Analytical Techniques Applicable to RoHS
ICP-AES
ICP-MS
AA
FT-IR
GCMS
UV
EDX
3/8
Thresholds
ELV
RoHS
(not decided)
Cd
100
100
Cr (VI)
1000
1000
Pb
1000
1000
Hg
1000
1000
PBB
--
1000
PBDE
--
1000
(ppm)
4/8
Flow Chart for Cd Analysis in Plastic
Start
Rapid Analysis (EDX)
<150ppm
150ppm or more
Precise Analysis (EDX)
5/8
ICP/AA
<100ppm
100ppm or more
OK
NG
NG
End
Flow Chart for Pb and Hg Analysis in Plastic
Strat
Rapid Analysis (EDX)
<1500ppm
1500ppm or more
Precise Analysis (RDX)
6/8
ICP/AA
<1100ppm
1100ppm or more
OK
NG
OK
End
Flow Chart for Cr(VI) Analysis in Plastic
Start
Rapid Analysis (EDX)
Total Cr
<500ppm
Total Cr Measurement
500ppm or more
Total Cr
Precise analysis (EDX)
<1100ppm
1100ppm or more
UV
<1100ppm
OK
1100ppm or more
NG
End
7/8
Cr(VI) Measurement
Flow Chart for Brominated Flame Retardant Analysis in Plastic
Start
Rapid Analysis (EDX)
<200ppm
200-50000ppm
Precise Analysis (EDX)
<350ppm
Determination of Br content
50000ppm or more
ICP
FT-IR
350ppm or more
PBB, PBDE
Others
GCMS
Determination of PBB
and PBDE content
OK
<1100ppm
1100ppm or more
NG
8/8
End
NG