PolySNAP 3 intro - University of Glasgow
Download
Report
Transcript PolySNAP 3 intro - University of Glasgow
Introducing PolySNAP 3
1
Bruker Confidential
17/07/2015
Introducing
PolySNAP 3
PolySNAP 3 is the successor product to the groundbreaking PolySNAP
PolySNAP provided powerful cluster analysis tools and clean, elegant
and informative graphic displays to allow for high-throughput analysis
of Powder X-Ray Diffraction patterns.
PolySNAP 3 has the same powerful tools, but allows them to be
employed to ANY kind of numeric data
• PXRD, Raman, IR, DSC, Melting Points…. Anything!
PolySNAP 3 allows up to four different datasets to be analysed
simultaneously
• (or a single dataset with up to four different processing options)
PolySNAP 3 combines the results from individual datasets to show the
overall picture of what’s going on
2
Bruker Confidential
17/07/2015
Multiple Datasets
Combined XRPD + Raman instruments now available – D8 Spectrolab
Applying multiple techniques to the same samples helps give
additional information to work with
How would we actually combine results from two such different
techniques ?
Automatically calculate optimal weighting for each entry in each
dataset
• Much more powerful than manually averaging results
3
Bruker Confidential
17/07/2015
Methodology
- PXRD + Raman
XRD results
n
Full profile matching
nxn
nxn
XRPD
Patterns
all patterns against all patterns
Correlation
Matrix
Distance
Matrix
Combined
results
nxn
Combine
n
Full profile matching
nxn
nxn
Raman
Patterns
all patterns against all patterns
Correlation
Matrix
Distance
Matrix
4
Bruker Confidential
17/07/2015
Distance
Matrix
Raman
results
5
Bruker Confidential
17/07/2015
6
Bruker Confidential
17/07/2015
Run on…
a single dataset
Just like PolySNAP:
»
- but can now select different kinds of input
»
- Separate automatic pre-processing defaults for
each type of data
- also new is the ability to transform spectra
- either Fourier transform or derivative (1st or 2nd)
»
»
»
7
Bruker Confidential
- can also specify a location to load sample image
files from (JPEG files)
17/07/2015
Analysis Tools:
Dendrogram
Similar patterns are clustered together
Position of ‘Cut-Level’ partitions the data into separate clusters
Too high?
Too low?
Just right
Adjust the cut-level to best
describe the data
8
Bruker Confidential
17/07/2015
Analysis Tools:
3D MMDS Plot
Each sphere is a pattern
The closer together two spheres are, the more similar they are
Similar patterns ‘clump’ together
Different patterns are far apart
Easy to spot outliers at a glance
As with all PolySNAP graphics, you can:
•
•
•
•
•
9
Zoom in, zoom out, rotate
Hide and show and drag labels
Change rendering quality
Change colour of background, axes etc.
Produce figures for publication
Bruker Confidential
17/07/2015
Multiple Methods:
Consistent Colouring
Changing the clustering
in the dendrogram
automatically updates
the colours in the other
plots.
Cluster colours from dendrogram
are used on MMDS plot so you can
compare the groupings from both
methods. Same results from both
increases confidence in the
accuracy of the results.
10
Bruker Confidential
17/07/2015
Analysis Tools:
Quantitative Analysis
Given reference phases, PolySNAP can identify possible mixtures and
perform fast quantitative analysis. Results are shown on the Cell
Display in the form of Pie Charts or Stacks.
11
Bruker Confidential
17/07/2015
Analysis Tools:
Cell Display
Cell Display is also
useful for seeing the
clustering result
colours superimposed
on e.g. the layout of
an original 96 well
plate from a highthroughput system.
12
Bruker Confidential
17/07/2015
Analysis Tools:
6D Plots –Sample Preparation Information
Automatically read sample preparation information from data file
headers or standalone CSV file
Plot any combination of this information as different variables in the
3D plot – vary size, shape and colour of plotted points
e.g. show different solvents as different
shapes
Vary the shape size with temperature,
the colour with time
See what initial variables correlate to
resulting materials
13
Bruker Confidential
17/07/2015
Analysis Tools:
Validation
Check the validity of the clustering using powerful statistical tests
•
•
•
•
Silhouettes – are these cluster memberships reasonable?
Fuzzy Clustering – should this pattern be in a different cluster?
Scree plots – how many clusters are needed to explain the data?
Minimum Spanning Trees – an alternative way to construct clusters
Silhouettes example:
• Pattern 21 scores poorly as a member of this cluster
• it is the least tightly connected in the dendrogram
• This turns out to be a mixture, rather than a pure phase
14
Bruker Confidential
17/07/2015
Analysis Tools:
High Dimensionality Viewers
Advanced visualisers to test if the clustering holds true in higher
dimensional space
Animated dataset ‘Grand Tour’
Parallel Coordinates Plots
Space Explorer View
15
Bruker Confidential
17/07/2015
Analysis Tools:
Pattern Thumbnail Viewer
Thumbnail colouring updated as dendrogram cut level is changed
Helps show which samples are grouped together in which clusters
Useful visual overview of smaller datasets
16
Bruker Confidential
17/07/2015
Analysis Tools:
Colour-coded Numeric Results
Draws the eye to help see patterns in the data
User-controlled colour scheme and cut-off points
17
Bruker Confidential
17/07/2015
Analysis Tools:
Peak Overlap Viewer
Overview of peak intensities and positions throughout the entire
dataset
Colouring can be user controlled
See at a glance if peaks coincide or overlap at similar angles
18
Bruker Confidential
17/07/2015
Run on…
Multiple Datasets
3 potential ways of working with PolySNAP…
1. Multiple types of data have been collected on the same samples
• e.g. there is a set of 96 samples, from which have been collected both
PXRD and Raman spectra
• Examine the clustering from the PXRD, and the Raman, and the combined
PXRD + Raman
o
Do the different methods agree? Do they contradict each other?
2. Multiple instances of the same type of data collected
• e.g. PXRD patterns collected on the same samples at different times, or
under different conditions
3. Investigate a single dataset under different processing options
• Compare side-by-side what difference turning background subtraction, etc.
on makes to the final results
19
Bruker Confidential
17/07/2015
Run on…
Multiple Datasets
Select
PXRD and
choose data
location
Select
Raman and
choose data
location
Select any
different
processing
options for
each
dataset
20
Click OK to
start
Bruker Confidential
17/07/2015
How much data?
For each individual dataset, PolySNAP can analyse up to 1,500
samples at once
Up to four different datasets can be input for each run
The datasets can be any combination of:
•
•
•
•
•
•
PXRD
Raman
DSC
IR
Other spectra data
Numeric
o
Numeric can be a correlation matrix, or ‘raw’ numeric data relating to the samples
being analysed
– e.g. Melting points
Data formats: RAW, Powder-CIF, ASCII, CSV, Raman SPC, Opus, …
21
Bruker Confidential
17/07/2015
Results Screen
22
Bruker Confidential
17/07/2015
Results Screen
Click on the dataset
name to switch
between different sets
of results – here,
choose between
PXRD and Raman
individually, or the
combined results
23
Bruker Confidential
17/07/2015
Results Screen
Click on the tabs to
see different display
screens to help you
interpret the results
24
Bruker Confidential
17/07/2015
Results Screen
Select a sample or
samples in the results
screen to see
information about it
and its profile
displayed below
Click the vertical tabs
to switch between
seeing the PXRD or
Raman profile for the
currently selected
patterns
25
Bruker Confidential
17/07/2015
Results Screen
Compare the clustering results from each datatype in turn
26
Bruker Confidential
17/07/2015
Results Screen
»
27
Bruker Confidential
Look at both the PXRD and Raman spectra to make sure this
clustering looks sensible
17/07/2015
Results Screen
Or select up to four
multiple datasets to view
results side by side…
28
Bruker Confidential
17/07/2015
Multiple Screens
Multiple Windows
Customers with multiple monitors can open separate results screens
on each one, allowing easy comparison of different results side-byside
29
Bruker Confidential
17/07/2015
Combined Datasets
Example 1
48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)
PXRD and Raman data collected
PXRD Data only:
• Splits form 3 into 2 separate clusters
Form 4
30
Form 3
Bruker Confidential
Form 2
17/07/2015
Form 3
Combined Datasets
Example 1
48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)
PXRD and Raman data collected
Raman Data only:
• Doesn’t distinguish between Form 3 and Form 4
Form 2
Forms 3 & 4
31
Bruker Confidential
17/07/2015
Combined Datasets
Example 1
48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)
PXRD and Raman data collected
Combined PXRD + Raman using Automatic Weights:
• Does much better than the individual methods alone
Form 4
32
Form 3
Bruker Confidential
Form 2
17/07/2015
Combine Results
Example 2
46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)
PXRD and Raman data collected
PXRD Data only:
• E3 and F7 in different clusters
33
Bruker Confidential
17/07/2015
Combine Results
Example 2
46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)
PXRD and Raman data collected
Raman Data only:
• E3 and F7 in same cluster!
34
Bruker Confidential
17/07/2015
Combine Results
Example 2
46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)
PXRD and Raman data collected
PXRD&Raman Data Combined:
• F7 highlighted as an outlier due to this inconsistency
»
»
35
Bruker Confidential
Other outliers (yellow) are
mixtures of the 2 forms
17/07/2015
Combined Results
Matching method does very well in distinguishing forms automatically
using either Raman or PXRD data
Combined results using Automatic Weights seem to do better than
either PXRD or Raman individually
Identification of pure phases / mixtures improved
Use of combined data highlights any inconsistencies in separate
analyses
• Such inconsistencies would not be obvious with only one data source
• User can then examine outliers manually in detail
Seeing similar clustering from multiple original data sources increases
confidence in the results
36
Bruker Confidential
17/07/2015
Quality Control
Given a set of reference patterns, new patterns can be considered to
be similar enough to the references to ‘pass’, or different enough to
‘fail.’
Graphical representation:
new samples within the green
Pass surface are OK, samples
falling outside the surface fail.
37
Bruker Confidential
17/07/2015
Pre-screening
Have a large dataset of
existing patterns (~100,000) ?
Compare a single new
unknown sample to the large
dataset in minutes
Get back a list of top 50 best
matches to the unknown
Perform PolySNAP clustering &
visualisation on the best
matches
Pre-screen a large dataset
down to a smaller, more
relevant subset
38
Bruker Confidential
17/07/2015
Other Features
Automatic Report Writer
Ability to run from command line - perform analysis as part of a script
Integration with other Bruker software
Audit-trail detailed logfile
Raw numeric results available for interrogation
Results automatically archived to encrypted file
Full manual and tutorial provided
View sample images alongside patterns
Manual analysis mode:
• Compare one pattern to many
• Detailed numeric breakdown of results
39
Bruker Confidential
17/07/2015
Dealing with
Large Datasets
40
Specially designed tools for dealing with large, complex datasets
Select subsets for re-analysis
View simplified dendrograms and 3D plots
Show/Hide selected clusters
Hide all but current cluster being investigated
Transparency options
Search options locate individual patterns of interest
Bruker Confidential
17/07/2015
PolySNAP M
Ideal for single, smaller datasets (up to 96 patterns)
PolySNAP M has dendrograms, 3D plots, prescreening and manual
analysis mode
41
Bruker Confidential
17/07/2015
Which PolySNAP
Do I Need?
Program Type
Input Data Types
Max No. Of Samples per run
6D plots of sample prep info
Sample JPEG display
Cluster Validation Tools
Report Writer
Re-run selected analysis
No. of clustering methods
Online documentation
Program Tutorial
Customisable Analysis Methods
Manual Matching Options
Interactive Dendrograms
3D MMDS Plots
3D PCA Plots
Numerical Results
Audit-trail Logfile
Amorphous Identification
Reference patterns for mixtures
Command-line run options
Quality Control mode
Combine multiple datasets
Multiple Monitor Support
42
Bruker Confidential
PolySNAP M
Commercial
Powder XRD
96
No
No
No
No
No
1
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
17/07/2015
PolySNAP 3
Commercial
PXRD, Raman, DSC, IR, Numeric, Other
4x 1500
Yes
Yes
Yes
Yes
Yes
5
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Support Services
Training
•
•
•
•
One and two-day in-depth training packages available
Gain detailed knowledge of advanced program functions
Use advanced options with trickier datasets with confidence
Look at your own data with
Customisation
• Personalised modifications to suit company-specific workflows
• Interface alterations
• Integration with other custom-software
43
Bruker Confidential
17/07/2015
www.bruker-axs.com
www.chem.gla.ac.uk/snap
44
Bruker Confidential