Presentation Title - Emerson Process Management

Download Report

Transcript Presentation Title - Emerson Process Management

FloBoss 104
Flow Manager
TM
Now, one flow computer is cost
effective for either rotary or turbine
metering.
Flow Computer Division
ESC to Exit
FB104
1 of 30
Introducing the FloBoss 104
TM

The FloBossTM 104 is a compact,
high-performance flow computer
that is cost effective for fiscal
measurement.

It performs API 21.1 compliant
flow measurement when used with
pulse-generating devices, such as
rotary, turbine, and ultrasonic
meters.

The FloBoss 104 shares its
advanced technology platform with
the FloBoss 103, its orifice
metering twin.
ESC to Exit
Flow Computer Division
FB104
2 of 30
Ideal for Rotary and Turbine Metering

The FloBoss 104 mounts
directly to a rotary or
turbine meter and easily
handles the slow rotational
speed of a rotary meter or
the high-speed pulse trains
generated by most turbine
meters.

When line pressure and
temperature are measured
along with the pulse train,
the FloBoss 104 can
provide high-accuracy flow
measurement.
ESC to Exit
Flow Computer Division
FB104
3 of 30
High Performance Pulse and Pressure Sensing


When used with a Rotary meter,
the Pulse Interface Module
creates and measures electrical
signals (pulses) from the rotary
meter and raw pressure inputs
from the pressure transducer.
When used with a Turbine input,
the pressure is measured by the
pressure transducer and pulses
from the turbine meter are
measured by the Pulse Input on
the optional I/O board.
ESC to Exit
Flow Computer Division
FB104
4 of 30
FloBoss 104 Typical Applications
ESC to Exit
Flow Computer Division
FB104
5 of 30
FloBoss 104 Functional Overview

The FloBoss 104 provides these outstanding
functional features:
–
–
–
–
–
–
–
–
–
–
API/AGA Compliant Flow Measurement
Historical Databases
Event and Alarm Logs
Integrated Communications
Spontaneous Report-by-Exception (SRBX) Host
Communication
Pass-Through Communications
Closed-loop PID Control
Logic and Sequencing Control
ROCLINK 800 Configuration Interface
Data Security
ESC to Exit
Flow Computer Division
FB104
6 of 30
API/AGA Compliant Measurement


The FloBoss 104
calculates gas flow in
accordance with AGA7
turbine flow calculations,
using AGA8
compressibility methods.
Pulse counts and
pressure measurement
come from the Sensor
Assembly, and gas
temperature is acquired
through an external RTD
probe.
ESC to Exit
Flow Computer Division
FB104
7 of 30
Historical Databases

The FloBoss 104 maintains
API Chapter 21.1 compliant
historical archives for
measured and calculated
values, and events/alarms.

Up to 35 standard history
points can be archived on an
hourly and daily basis for up
to 35 days.

An extended history database
supports data logging at
intervals from 1 to 60
minutes, giving operators the
flexibility to meet the needs of
advanced applications.
ESC to Exit
Flow Computer Division
FB104
8 of 30
Event and Alarm Logs

The Event Log records
the last 240 parameter
changes and power
on/off cycles.

The Alarm Log records
the last 240 occurrences
of alarms (set or clear).

The logs can be viewed,
saved to a disk file, or
printed by using
ROCLINK 800 software.
ESC to Exit
Flow Computer Division
FB104
9 of 30
Integrated Communications

The FloBoss 104 offers a built-in
EIA-485 port and an optional
EIA-232 port or dial-up modem
port for host communications.

An optional spread-spectrum
radio interface supports either
FreeWave M-Series or
MaxStream 9X Stream spreadspectrum radios that fit entirely
within the FloBoss 104
enclosure.
ESC to Exit
Flow Computer Division
FB104
10 of 30
SRBX Host Communication

Spontaneous Report-ByException (SRBX)
communication allows
the FloBoss 104 to
automatically report any
alarm to a host
computer.

SRBX can be performed
over a dial-up modem or
serial line to a host that
is set up for receiving
field-initiated calls.
ESC to Exit
Flow Computer Division
FB104
11 of 30
Pass-Through Communications

Pass-through gives the
FloBoss 104 the capability to
pass information between a
host and devices connected
to the FloBoss 104 that use
ROC or Modbus protocol.

Pass-through reduces the
cost of communication when
several devices are
geographically grouped.

Pass-through is available for
use with RS-485, RS-232, or
dial-up modem connections.
ESC to Exit
Flow Computer Division
FB104
12 of 30
Closed Loop PID Control

PID (Proportional,
Integral, and Derivative)
closed-loop control
provides stable
operation of a feedback
control loop that
employs a regulating
device, such as a control
valve.

The PID loop has its
own user-defined input,
output, and override
capability.
ESC to Exit
Flow Computer Division
FB104
13 of 30
Logic and Sequencing Control

Analog and discrete
sequencing control is
implemented through a
Function Sequence Table
(FST).

The FST defines the
actions to be performed
by the FloBoss 104
through a series of
Functions.

The FST is developed
using ROCLINK 800
software.
ESC to Exit
Flow Computer Division
FB104
14 of 30
ROCLINK 800 Configuration Interface

ROCLINK 800 is the easyto-use software for
configuration and
downloading data.

Compatible with other
FloBoss and ROC products
for mixed-product
installations.

On-line Help screens get
first-time users up and
running quickly.
ESC to Exit
Flow Computer Division
FB104
15 of 30
Data Security



A maximum of 16 log-on
identifiers (IDs) for operators
can be stored.
The log-on ID entered into
ROCLINK must match one of
the stored IDs for the unit to
communicate.
Both the operator interface and
host can have the same
security. Security levels may
be determined by user and
access level.
ESC to Exit
Flow Computer Division
FB104
16 of 30
FloBoss 104 Technical Features

Sensor assembly and
rotary meter interface

32-bit Processor

Built-in Battery Pack & Charger

Embedded Communications

Expandable I/O

Rugged CSA-Approved Design

Local Operator Display

Solar Panel and Mast
ESC to Exit
Flow Computer Division
FB104
17 of 30
FloBoss 104 Component Overview
Battery Pack
& Charger
LCD
Processor
Memory
Backup
Termination
Board
Modem / RS232
Backplane
Pulse Interface Module
ESC to Exit
Flow Computer Division
FB104
18 of 30
High-Accuracy Pulse Interface Module

Generates 1,000 pulses /
revolution for high-resolution
measurement

Uses reliable non-contact pulse
sensing

Built-in pressure transducers
measure upstream and
downstream pressure

Bi-directional pulse detection and
diagnostics for easy installation,
setup, and maintenance

No gear trains to load down the
metering device and cause
inaccuracies.
ESC to Exit
Flow Computer Division
FB104
19 of 30
Built-n Pressure Transducers



One pressue transducer
can measure line
pressure and the other
downstream or station
inlet pressure if desired.
Accuracy is 0.35% of
Span for all range
options.
Range Options are:
– 0 to 100 psi (0 - 6.9 bar)
– 0 to 300 psi (0 - 20.7 bar)
– 0 to 1000 psi (0 - 69 bar)
ESC to Exit
Flow Computer Division
FB104
20 of 30
32-Bit Processor / Backplane

High performance 32-bit
processor is designed for
low-power applications.

Memory consists of:
Backplane
– 128 Kb flash boot ROM
– 2 Mb flash program ROM
– 512 Kb of data RAM

All boards plug into a
backplane making removal
and replacement quick and
easy.
Processor
ESC to Exit
Flow Computer Division
FB104
21 of 30
Built-In Battery Pack

Rechargeable lead acid
batteries provide more than
15 days of autonomy, at
one modem poll per day,
without recharging.

Real-time clock and static
RAM are backed up with a
3.6V lithium battery.
ESC to Exit
Flow Computer Division
FB104
22 of 30
Embedded Communications

Local Operator Interface
port uses RS-232C format.

Standard RS-485 port is
configurable for 600 to
19.2 K baud.

Communication to a Host is
supported by an optional
RS-232 or modem card.

RS-232 &
Modem
Cards
Spread
Spectrum
Radio
Available protocols include
ROC or Modbus Slave
(ASCII or RTU).
ESC to Exit
Flow Computer Division
FB104
23 of 30
Expandable I/O

Input for 2 or 3-wire RTD
element.

Diagnostic inputs for internal
voltage, battery voltage, and
enclosure/battery temperature
are built-in.

Optional I/O board adds 6
channels of I/O to further
increase its measurement and
control capabilities.
Termination Board
ESC to Exit
Flow Computer Division
FB104
24 of 30
Rugged CSA-Approved Design

The FloBoss 104 is approved for use in
Class I, Division 1 and Division 2
areas.

The Solar Panel and Mast Assembly
are approved for use in Class I,
Division 2 areas only.

Housing and end caps are die-cast
aluminum alloy with iridite plating and
paint.

Field wiring routes through sidemounted conduit ports and connects to
the termination board located behind a
removable end cap.
ESC to Exit
Flow Computer Division
FB104
25 of 30
Local Operator Display (Optional)

Flow information scrolls on a
two-line liquid crystal display
(LCD).

Values (8 numerals) and
descriptions (5 alpha-numeric
characters) are displayed.

Users configure displayed
information according to their
needs.
ESC to Exit
Flow Computer Division
FB104
26 of 30
Solar Panel and Mast (Optional)

Optional solar panel and
mast attach to the top of
the FloBoss 104.

Solar panel can be
positioned 360 degrees in
azimuth and 90 degrees in
elevation for optimal sun
coverage.

A 2-watt or 5-watt solar
panel can operate the
FloBoss 104 indefinitely in
a typical installation,
depending on radio
useage.
ESC to Exit
Flow Computer Division
FB104
27 of 30
Go With the Leader in Process Control...
Process
Management
Network
Power
Appliance
Solutions
Climate
Technologies
Motor
Technologies
Industrial
Automation
Professional
Tools
Storage
Solutions
ESC to Exit
Flow Computer Division
FB104
28 of 30
Emerson Power &
Water Solutions
...And the Leader in Products and Service


Emerson Process
Management offers the
industry's broadest array of
process-automation
products.
So it's not surprising that,
in an independent survey
conducted by Control
magazine, users have once
again ranked our products
first in more categories
than any other supplier.
1st/2nd/3rd PLACE FINISHES
Emerson
Rockwell
Honeywell
Invensys
Siemens
ABB
17
16
14
15
5
#1 IN SERVICES
Rated “Very Good” or
better in 33 Service
Categories
More than twice our
closest competitor
ESC to Exit
Flow Computer Division
39
FB104
29 of 30
Go with Emerson Process Management!

For detailed information on the
FloBoss 104 and other Fisher
products, contact your Emerson
Process Management Representative
or call:
– 1-800-807-0730
(U.S. & Canada only)
– 1-641-754-3449 (Worldwide)

You can also visit us on the World
Wide Web at:
– www.EmersonProcess.com/flow
ESC to Exit
Flow Computer Division
FB104
30 of 30