Presentation Title

Download Report

Transcript Presentation Title

FloBoss 103
Flow Manager
TM
The Cost-Effective Alternative
to Chart Recorders.
Flow Computer Division
ESC to Exit
FB103
1 of 29
11-02-04
Say Goodbye to Chart Recorders...

Manually gathering and
integrating charts is time
consuming, labor intensive, and
costly.

Low accuracy, off-chart
readings, inking problems, and
malfunctions mean more lost
and unaccounted gas.

Chart recorders provide few
capabilities beyond pressure
and temperature measurement.
ESC to Exit
Flow Computer Division
FB103
2 of 29
11-02-04
And to Complicated EFM Installations...

Typical EFM installations
are a maze of solar panels,
battery boxes, radios,
antennas, and wiring
making installation difficult
and costly.

Engineering these
installations can be time
consuming, and the end
result may not meet
performance expectations.
ESC to Exit
Flow Computer Division
FB103
3 of 29
11-02-04
And Hello to the FloBoss 103

The FloBoss 103 provides fast,
convenient, and inexpensive
electronic retrieval of gas flow
data locally or remotely.

The FloBoss 103 delivers higher
accuracy and eliminates chart
problems. The result, less lost
and unaccounted gas.

The FloBoss 103 integrates
batteries, communication cards,
and sensor into a single, easyto-install unit.
ESC to Exit
Flow Computer Division
FB103
4 of 29
11-02-04
The FloBoss 103 Mission

To fulfill the need for a high-performance,
compact single-run flow computer that is the
ideal replacement for the traditional paper chart
recorders used in natural gas flow
measurement.

To provide API Chapter 21.1 compliant flow
measurement in a unit that is self contained -i.e., batteries and communications are built-in.
All you need to add is an RTD and a 2- or 5Watt solar panel for full functionality.
ESC to Exit
Flow Computer Division
FB103
5 of 29
11-02-04
Functional Overview

The FloBoss 103 provides these outstanding
functional features:
–
–
–
–
–
–
–
–
–
–
AGA Flow Calculations
Historical Databases
Event and Alarm Logs
Data Security
Embedded Communications
Spontaneous Report-by-Exception (SRBX)
Host Communication
Pass-Through Communication
Closed-loop PID Control
Logic and Sequencing Control
ROCLINK 800 Configuration Interface
ESC to Exit
Flow Computer Division
FB103
6 of 29
11-02-04
AGA Flow Calculations

Gas flow is calculated for
both volume and energy in
accordance with the 1992
AGA Report No. 3.

AGA 8 compressibility
calculations use Detail,
Gross I, or Gross II
methods.

Meter setup is made quick
and easy using fill-in-theblanks data entry.
ESC to Exit
Flow Computer Division
FB103
7 of 29
11-02-04
Historical Databases

The FloBoss 103 maintains
API Chapter 21.1 compliant
historical archives for
measured and calculated
values, and events/alarms.

Up to 35 standard history
points can be archived on an
hourly and daily basis for up
to 35 days.

An extended history database
supports data logging at
intervals from 1 to 60
minutes, giving operators the
flexibility to meet the needs of
advanced applications.
ESC to Exit
Flow Computer Division
FB103
8 of 29
11-02-04
Event and Alarm Logs

The Event Log records
the last 240 parameter
changes and power
on/off cycles.

The Alarm Log records
the last 240 occurrences
of alarms (set or clear).

The logs can be viewed,
saved to a disk file, or
printed by using
ROCLINK 800 software.
ESC to Exit
Flow Computer Division
FB103
9 of 29
11-02-04
Data Security



A maximum of 16 log-on
identifiers (IDs) for operators
can be stored.
The log-on ID entered into
ROCLINK 800 must match one
of the stored IDs for the unit to
communicate.
Both the operator interface and
host can have the same
security. Security levels may
be determined by user and
access level.
ESC to Exit
Flow Computer Division
FB103
10 of 29
11-02-04
Embedded Communications


The FloBoss 103 offers a
built-in EIA-485 port and an
optional EIA-232 port or dialup modem port for host
communications.
An optional spread-spectrum
radio interface supports either
FreeWave M-Series or
MaxStream 9X Stream
spread-spectrum radios that
fit entirely within the FloBoss
103 enclosure.
ESC to Exit
Flow Computer Division
FB103
11 of 29
11-02-04
SRBX Communication

Spontaneous Report-By
-Exception (SRBX)
communication allows
the FloBoss 103 to
automatically report any
alarm to a host
computer.

SRBX can be performed
over dial-up modem or
serial line to a host that
is set up for receiving
field-initiated calls.
ESC to Exit
Flow Computer Division
FB103
12 of 29
11-02-04
Pass-Through Communications

Pass-through gives the
FloBoss 103 the capability to
pass information between a
host and devices connected
to the FloBoss 103 that use
ROC or Modbus protocol.

Pass-through reduces the
cost of communication when
several devices are
geographically grouped.

Pass-through is available for
use with RS485, RS232, or
dial-up modem connections.
ESC to Exit
Flow Computer Division
FB103
13 of 29
11-02-04
PID Loop Control

PID (Proportional,
Integral, and Derivative)
closed-loop control
provides stable
operation of a feedback
control loop that
employs a regulating
device, such as a control
valve.

The PID loop has its
own user-defined input,
output, and override
capability.
ESC to Exit
Flow Computer Division
FB103
14 of 29
11-02-04
Logic and Sequencing Control

Analog and discrete
sequencing control is
implemented through a
Function Sequence Table
(FST).

The FST defines the
actions to be performed
by the FloBoss 103
through a series of
Functions.

The FST is developed
using ROCLINK 800
software.
ESC to Exit
Flow Computer Division
FB103
15 of 29
11-02-04
ROCLINK 800 Configuration Interface

ROCLINK 800 is the easyto-use software for
configuration and
downloading data.

Compatible with most other
FloBoss and ROC products
for convenience in mixedproduct installations.

On-line Help screens get
first-time users up and
running quickly.
ESC to Exit
Flow Computer Division
FB103
16 of 29
11-02-04
FloBoss 103 Technical Features

High-Accuracy Dual-Variable Sensor

32-bit Processor

Built-in Battery Pack

Communications Cards / Radio

Termination / I/O Board

Rugged CSA-Approved Design

Local Operator Display

Solar Panel and Mast
ESC to Exit
Flow Computer Division
FB103
17 of 29
11-02-04
FloBoss 103 Component Overview
Battery Pack
& Charger
LCD
Processor
Memory
Backup
Termination
Board
Modem / RS232
Backplane
Dual-Variable Sensor
ESC to Exit
Flow Computer Division
FB103
18 of 29
11-02-04
High-Accuracy Dual-Variable Sensor

Dual-variable sensor uses
Rosemount capacitance
cell technology.

Measures static and
differential pressure.

Accuracy is +0.1%
standard or +0.075%
optional.

High stability design means
less calibration.

Exclusive co-planer flange
for easy installation.
ESC to Exit
Flow Computer Division
FB103
19 of 29
11-02-04
32-Bit Processor / Backplane

High performance 32-bit
processor is designed for
low-power applications.

Memory consists of:
Backplane
– 128 Kb flash boot ROM
– 2 Mb flash program ROM
– 512 Kb of data RAM

All boards plug into a
backplane making removal
and replacement quick and
easy.
Processor
ESC to Exit
Flow Computer Division
FB103
20 of 29
11-02-04
Built-In Battery Pack

Rechargeable lead acid
batteries provide more than
15 days of autonomy, at
one modem poll per day,
without recharging.

A 2- or 5-Watt solar panel
will operate the FloBoss
103 indefinitely in a typical
installation.

Real-time clock and static
RAM are backed up with a
3.6v lithium battery.
ESC to Exit
Flow Computer Division
FB103
21 of 29
11-02-04
Communications Cards / Radio

Local Operator Interface port
uses RS-232C format.

Standard RS-485 port is
configurable for 600 to
19.2 K baud.

Communication to a Host is
supported by an optional RS232 or modem card, or built-in
spread spectrum radio.

Available protocols include ROC
or Modbus Slave (ASCII or
RTU).
ESC to Exit
Flow Computer Division
FB103
22 of 29
11-02-04
Termination / I/O Board

2 or 3-wire RTD element input
is built-in.

Diagnostic inputs for internal
voltage, battery voltage, and
enclosure/battery temperature
are built-in.

Optional I/O board provides 6
channels of I/O that are switchselectable in combinations of
analog and discrete inputs and
outputs, and pulse inputs.
ESC to Exit
Flow Computer Division
FB103
23 of 29
11-02-04
Rugged, CSA-Approved Design

The base FloBoss 103 is approved
for use in Class I, Division 1 and
Division 2 areas.

The Solar Panel and Mast Assembly
are approved for use in Class I,
Division 2 areas only.

Housing and end caps are die-cast
aluminum alloy with iridite plating
and paint.

Field wiring routes through sidemounted conduit ports and connects
to the termination board located
behind a removeable endcap.
ESC to Exit
Flow Computer Division
FB103
24 of 29
11-02-04
Local Operator Display (Optional)

Flow information is scrolled
on a two-line liquid crystal
display (LCD) when
activated by the user.

Top line displays values
(8 numerals) and bottom
line displays descriptions
(5 alpha-numeric
characters).

Information displayed is
configured by the user
according to their needs.
ESC to Exit
Flow Computer Division
FB103
25 of 29
11-02-04
Solar Panel and Mast (Optional)

Optional solar panel and
mast attach to the top of
the FloBoss 103.

Solar panel can be
positioned 360 degrees in
azimuth and 90 degrees in
elevation for optimal sun
coverage.

The 2-Watt panel
measures only 4 by 6.25
inches and the 5-Watt only
8.75 by 9 inches.
ESC to Exit
Flow Computer Division
FB103
26 of 29
11-02-04
Go With the Leader in Process Control...
Process
Management
Network
Power
Appliance
Solutions
Climate
Technologies
Motor
Technologies
Industrial
Automation
Professional
Tools
Storage
Solutions
ESC to Exit
Flow Computer Division
FB103
27 of 29
11-02-04
Emerson Power &
Water Solutions
...And the Leader in Products and Service


Emerson Process
Management offers the
industry's broadest array of
process-automation
products.
So it's not surprising that,
in an independent survey
conducted by Control
magazine, users have once
again ranked our products
first in more categories
than any other supplier.
1st/2nd/3rd PLACE FINISHES
Emerson
Rockwell
Honeywell
Invensys
Siemens
ABB
17
16
14
15
5
#1 IN SERVICES
Rated “Very Good” or
better in 33 Service
Categories
More than twice our
closest competitor
ESC to Exit
Flow Computer Division
39
FB103
28 of 29
11-02-04
Go with Emerson Process Management!

For detailed information on the
FloBoss 103 and other great Flow
Computer Division products, contact
your Emerson Process Management
Representative or call:
– 1-800-807-0730
(U.S. & Canada only)
– 1-641-754-3449 (Worldwide)

You can also visit us on the World
Wide Web at:
– www.EmersonProcess.com/flow
ESC to Exit
Flow Computer Division
FB103
29 of 29
11-02-04