Transcript Tri-Tech Medical
Tri-Tech Medical Inc.
Medical Gas Outlets
Medical Gas Outlets
DISS Ohmeda style Allied style Puritan style Recessed wall DISS Recessed ceiling Surface wall Console / Headwall Ambulance / Surgical Arm
Common Backs Recessed/Console 360º swivel inlet tube 1/2” OD copper tubing Accommodates all styles of Outlet Latch Plates ETL listed Ambulance/ Surgical Arm 360º swivel inlet tube DISS or hose barb Accommodates all styles of Outlet Latch Plates ETL listed
DISS Outlets
Frontall™ design Gangable Full faceplate color coding 5 inch centers Primary & secondary checks 360° positioning of extension tube
DISS Surface Outlets Frontall™ design Full faceplate color coding Primary & secondary checks
Frontall™ Feature
Allows routine service of both the primary and secondary check valves
without
removing the nameplate or gas specific portions.
Very fast & easy to service Primary check cartridge
Repairing DISS Front Bodies These parts would be ordered separately Cartridge (Negative and Positive gases) Primary Check Seat and Ball Check (Positive gases only) Chrome-Plated Body
Ohmeda Style Outlets
Ohmeda Style Outlets Accepts Ohmeda gas specific compatible male adaptors Gangable 5” centers Allows routine service of both the primary and secondary check valves.
Full faceplate color coding
Ohmeda Style Surface Outlet Accepts Ohmeda gas specific compatible male adaptors Allows routine service of both the primary and secondary check valves.
Full faceplate color coding
Repairing Ohmeda style fronts Remove screws Remove body and plate
U-clip and washer remain.
Front body and plate
Replace body Replace plate and screw
XQ1000-D Ohmeda style Front Latch Body Can be ordered as an assembly, or in parts
Allied Style Outlets
Allied Style Outlets Accepts Allied style gas specific compatible male adapters Gangable, 5” centers Full faceplate color coding 1/2” OD copper tubing Metal back and front plates 360º swivel inlet tube
Allied Style Surface Outlets Accepts Allied gas specific compatible male adapters Full faceplate color coding
Repairing an Allied Style Front Remove screws Remove body and plate
Position o-ring and washer on new body Place body on housing and replace plate
Replace Screws
XA1000-D Front Latch Body Can be ordered as an assembly, or in parts
Puritan Style Outlets
Puritan Style Outlets Accepts Puritan style gas specific compatible male adapters Gangable, 5” centers Full faceplate color coding 1/2” OD copper tubing Metal back and front plates 360º swivel inlet tube
Puritan Style Outlets Accepts Puritan gas specific compatible male adapters Full faceplate color coding
Repairing a Puritan Style Front Using manual screwdriver, remove screws Remove body and small plate
Remove ONLY these parts
Replace parts or entire body Screw plate back in place with Manual screwdriver. Do not over tighten
XP1000-E Puritan Latch Body Can be ordered as an assembly or in parts
Console / Headwall Outlets Available in DISS, Ohmeda, Puritan and Allied styles DISS style includes Frontall™ features Full faceplate color coding Optional trim plate available
Console / Headwall Outlets
Console / Headwall Outlets
Ambulance / Surgical Arm Outlets Available in DISS and Quick Connect styles DISS and hose barb inlet connections DISS includes Frontall™ features Full faceplate color coding
DISS x ¼” npt outlets and DISS x hose barb outlets
Fairfield Rail
Fairfield Rail Outlets Three different styles
Outlet Conversion Kits
Conversion Kits
Conversion Kit - Disassembly
Conversion Kits - Disassembly
Conversion Kits - Installation
Trim Plates Single gang through six gang Large array of on center spacing Can be customized to meet your needs
Ohmeda to Ohmeda Conversion Kits Available for Diamond I to Diamond III Available for Diamond II to Diamond III Easy to install Easy to service
Other Ohmeda Conversion Kits Available for Melco/Foregger/Linde 9/16-18 and Chemetron/NCG to Diamond III Easy to install and service
NFPA 99 REQUIREMENTS FOR STATION OUTLETS/INLETS
GAS SPECIFIC TRI-TECH PRODUCT YES
STATION OUTLET TO HAVE PRIMARY AND SECONDARY CHECK YES
STATION INLET TO HAVE PRIMARY CHECK (SECONDARY CHECK PERMITTED) YES
SECONDARY VALVE TO CLOSE WHEN PRIMARY VALVE IS REMOVED YES YES YES
EACH OUTLET/INLET LEGIBLY IDENTIFIED ACCORDING TO 5.1.11.3
THREADED OUTLETS/INLETS SHALL COMPLY WITH CGA V-5 (DISS)
STATION OUTLET/INLET COMPONENTS THAT ARE GAS SPECIFIC NOT INTERCHANGEABLE
COPPER TUBES ON STATION OUTLETS SHALL BE 3/8 OD MIN AND LESS THAN 8 INCHES LONG COPPER TUBES ON STATION INLETS SHALL BE ½ OD MIN AND LESS THAN 8 INCHES LONG
ADDITIONAL TESTING PERFORMED BY TRI-TECH INITIAL PRESSURE TEST AND FINAL TIE IN TEST REQUIRED FOR LEAKAGE AS WELL AS THE OPERATIONAL PRESSURE TEST REQUIRED FOR FLOW IS PERFORMED ON ALL STATION OUTLETS/INLETS PRIOR TO SHIPPING YES YES YES
Tri-Tech Medical Inc.
Gas Control Panels and Gas Control Panel Conversion Kits
Gas Control Panel Stainless steel front Self-relieving regulator Frontall™ DISS outlet features High quality ball valve Painted steel rough-in box 2” Inlet & outlet pressure gauges
TRI-TECH MEDICAL GAS CONTROL PANELS: FEATURES INCORPORATES A SELF RELIEVING REGULATOR SUPPLY GAGE AND DELIVERY GAGE CARTRIDGE STYLE DISS OUTLET FOR EASY SERVICING USER INSTRUCTIONS ON THE PANEL OUTLET RISER FOR FEEDING DOWNSTREAM EQUIPMENT OR ADDITIONAL OUTLETS CAN DELIVER UP TO 250 PSI WITH AN ADEQUATE SUPPLY PRESSURE CAN BE ORDERED WITH A DISS NITROGEN, INSTRUMENT AIR, OR CARBON DIOXIDE OUTLET NP100 - NITROGEN DISS 1120 IP100 - INSTRUMENT AIR CP100 - CARBON DIOXIDE DISS 2080 DISS 1080
MIDAS REX EQUIPMENT: APPROX 5% OF TOOLS IN FIELD ARE OLDER TOOLS REQUIRING 50 - 200 PSI - 900 CFH - 425 LPM NEW TOOLS REQUIRE 20 - 120 PSI - 720 CFH - 340 LPM OR 481 CFH - 227 LPM NITROGEN CONTROL PANEL MAXIMUM FLOW CAPACITY BASED ON 180 PSI INLET FLOWING TO ATMOSPHERE STATIC DEL FLOW PRESSURE PSIG SCFH 100 110 930 1030 FLOW LPM 440 486 DEL PRESS FLOWING PSIG 96 106 120 130 150 170 1110 1150 1175 1180 524 543 555 557 114 119 120 120
Gas Control Panel Conversion Converts existing panels by several major brands Same features as our regular panel Easy to install using a universal mounting plate over existing back box
Gas Control Panel Conversion Existing back box
Gas Control Panel Conversion Installing conversion connections
Gas Control Panel Conversion Installing conversion plate
Gas Control Panel Conversion Back of the front panel conversion
Gas Control Panel Conversion Connecting tube
Gas Control Panel Conversion Installing gas control panel