Transcript Slide 1
EN779:2012 & Eurovent Energy Efficiency Classification Steve Devine Clean air solutions Eurovent Energy Efficiency Classification Clean air solutions © CAMFIL FARR 16/07/2015 – Independent label • Makes filters comparable – Escape price discussions • Talk about IAQ and • Energy – Select best solution • Energy saving (Eurovent) • IAQ (EN779:2012) • Minimum efficiency (EN779:2012) 2 • Energy rating system using EN779:2012 • Advantages 3 What´s needed to be able to classify filters • EN779:2012 test rig • EN779:2012 Test Report Clean air solutions © CAMFIL FARR 16/07/2015 • ASHRAE Dust feeding Airborne Particulate Size Outdoor air Average Diameter ~0.08mm ASHRAE Dust Average Diameter ~7.7mm 100x difference in size, so what does loading with ASHRAE dust tell you? Answer: How your filter will perform when it is challenged with ASHRAE dust, Do you have ASHRAE dust in your system??? Clean air solutions ASHRAE Dust ΔP vs. Real Life ΔP Actual Average ΔP DPF DP ASHRAE Dust = 0.63” WG Dx DP ”Real Life” = 0.46” WG DPI Simple averaging ΔP (DPI+DPF)/2 = 0.75” WG 1.30 1.20 DPF 1.10 Resistance 1.00 0.90 0.80 0.70 0.60 Straight Line 0.50 ASHRAE Dust 0.40 DPI 0.30 "Real Life" 0.20 0 Clean air solutions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 So is ASHRAE Dust a Problem? 6 • It is an acceptable compromise • This procedure is a Method of Calculation using existing test data – EN779 uses ASHRAE test dust – Data is available – Better than any alternative method available at this time – Not 100% true – LCC Green will correct the ones that fail Clean air solutions © CAMFIL FARR 16/07/2015 • Generally, a filter with a “better” ASHRAE loading curve will have a lower energy cost © CAMFIL FARR 16/07/2015 ”Low energy consumption in combination with a high indoor air quality.” 7 The system is available in Europe Clean air solutions ASHRAE and ISO? • ASHRAE – Uses ASHRAE dust loading 8 – Guideline Project Committee is forming • Proposed method is similar • Proposed method is different – Data from 52.2, ISO 16890 or EN779 – 4-5 years minimum from a document – Started a Work Item in 2011 – Stopped the WI in 2012 • Project is on hold – If it gets started again, it will also be 4-5 years from a document Clean air solutions © CAMFIL FARR 16/07/2015 • ISO G4 / MERV 8 M5 / MERV 9-10 M6 / MERV 11-12 F7 / MERV 13 F8 / MERV 14 Min Load 350g 250g 250g 100g 100g ≥ 35% ≥ 55% 0 – 1200 0 – 1600 Min Eff A 0 – 600 0 – 650 0 – 800 B >600 – 700 >650 – 780 >800 – 950 >1200 – 1450 >1600 – 1950 C >700 – 800 >780 – 910 >950 – 1100 >1450 – 1700 >1950 – 2300 D >800 – 900 >910 – 1040 >1100 – 1250 >1700 – 1950 >2300 – 2650 E >900 – 1000 >1040 – 1170 >1250 – 1400 >1950 – 2200 >2650 – 3000 F >1000 – 1100 >1170 – 1300 >1400 – 1550 >2200 – 2450 >3000 – 3350 G >1100 >1300 >1550 • All Values are calculated kWh per Eurovent 4/11 Clean air solutions >2450 >3350 © CAMFIL FARR 16/07/2015 Filter Class 9 How would our USA products rate? Efficiency kWh Eurovent Rating Hi-Flo ES, 22” M13 (F7) 1197 A Hi-Flo ES, 12” M13 (F7) 2195 E Durafil ES M13 M13 (F7) 959 A Durafil 2V M13 M13 (F7) 1576 C AAF VXL M13 (F7) 1117 A Riga-Flo M13 (F7) 1666 C AP-3 M8 (G4) 12980 G 30/30 M8 (G4) 4196 G AAF PP HC M8 (G4) 24417 G The lower the kWh value the better the performance Why are any of you buying a 12” HF ES???? Difference between 4V and 2V AAF VXL has a better kWh than the HF ES, but not in the field… Aeropleat – Not Good, but What – 30/30??? AAF PP has same rating as a 30/30… Clean air solutions © CAMFIL FARR 16/07/2015 • • • • • • Filter 10 How would some USA products do in Eurovent 4/11? The biggest issues facing ASHRAE and ISO • The USA uses pleated filters • The Eurovent methodology shows NO differentiation between any pleats 11 – Based on energy, pleats are horrible products – The AP3 and 30/30 are both a “G” – The AAF PP is also a “G” at ½ the 30/30 price – The ASHRAE and ISO methods will have to show differentiation of pleated filters – Similar to why there is an Arrestance test method and a Particle Removal Efficiency test method – different levels of filtration Clean air solutions © CAMFIL FARR 16/07/2015 • This is the problem facing ASHRAE and ISO Clean air solutions © CAMFIL FARR 16/07/2015 12