Transcript Slide 1
Temporary C/M for Water dripping in 310 DC Apply instant bonding glue( Quick fix,Anabond etc) across the strip Paste the strip on rib( located below the evaporator) and press it After pasting the Strip water falling from evaporator falls chiller tray and no splashing on ref compartment Applicomp, Bangalore Permanent C/M for Water dripping in 310 DC Topic : Water Dripping in Ref compartment – 310 DC Description : Modification of rib below Evaporator to ensure water drips in Chiller tray during defrost Previous condition Chiller tray Improved condition Water falling from rib in chiller tray edge and splashing Rib Width – 39 mm Backlogs: 39mm Chiller tray Rib Width increased to 52 mm Water falling inside chiller tray & no splashing out side 52 mm Person Name: Gururaj Department: Production Area: Vacuum Forming Enrichments: Quality 1. Water drops from rib falling near edge 1. Rib width increased to 52 mm 2. During defrost water drops falling of the chiller tray. inside chiller tray 2. In some sets water drops splashing out 3. There is no splashing of water drops in side chiller tray and falling in ref ref compartment compartment Continual Improvement Process Date : 07/06/14 Productivity 5S & 3R Cost Safety Others Applicomp, Bangalore √