Green Design and Construction for Florida
Download
Report
Transcript Green Design and Construction for Florida
The Latest Cost Effective Energy Efficient
Lighting Technologies
(and a few other green commercial ideas)
Presented by:
Eco-$mart, Inc.
An EPA ENERGY STAR Partner
Operated with Guidance from the nonprofit Florida House Institute for
Sustainable Development
The Florida House Learning
Center
Created by the Nonprofit Florida House Institute for Sustainable Development
and Sarasota County Cooperative Extension Service
The Florida House was opened to the public on Earth Day, 1994
About Eco-$mart, Inc.
• An EPA ENERGY STAR Partner
• A Partnership with the Nonprofit Florida House
Institute for Sustainable Development (FHI):
– Free Eco-$mart Materials Consultation
– Distributes / Installs Approved Systems
– Provides Energy Efficiency Ratings
– Connects to Energy Efficient Financing
– Educational Seminars for Public and Trades
• A Portion of Proceeds Benefit Nonprofit (FHI)
Our Priorities for Selecting Green
Building Materials
1. Enhances efficiency, health, disaster resistance.
2. Reduces maintenance, construction time, construction costs,
operating costs.
3. If not capital cost saving, then at least creates positive
cash flow for building owners.
4. Locally available, supportable.
Commercial Green Technologies
• Energy Efficient Lighting
– High Output Fluorescent
– LED
– Induction (w/Solar Hybrid)
– Daylighting
• Water-Cooled A/C
• Membrane Core ERV
• Eco-Flector Window Retrofit
• Passive Solar Water Heating
• Brac Grey Water Systems
T5 Electronic Ballast High
Output Lighting
• Saves 40 to 50 percent of energy costs vs. Metal Halide High Bay
• Higher color rendition (82 CRI), best lumen maintenance (95%)
• Instant re-strike, lightweight, affordable fixture
LED Replacement Lamps
• No ballasts, no
mercury.
• 50,000 hour
warranty
• Available in
warm white and
daylight colors
• 3W LED = 15W
CFL = 60W
Incandescent
LED HID Retrofits
Retrofit 400W MH fixture with 93W LED. Improve light quality, 50,000 hour lamp life for
reduced maintenance. Custom kit for any fixture: wall pack, parking garage, parking lot.
LED Photos
Left Side 400W MH
Right Side 88W LED
LED Photos
LED on Left Bridge Span
Induction Lighting
(Electrode-less Fluorescent)
Induction
Lighting
Metal Halide
HPS
Watts - Electrical
Usage
200w
450w
450w
Kelvin Temp
5000k
3700k
2100k
CRI
90+
65
22
Rated Lamp Life
100,000
hours
20,000 hours
21,000 hours
Fixture S/P Factor
2.0
1.26
0.76
Fixture Lumens Photopic
20,500
28,800
40,800
Visual Acuity Lumens
41,000
36,288
31,008
Visual Acuity Lumens
Per Watt
191
79
67
Operating Temperature
200° F
900° F
900° F
Annual Operating
Cost
$183.96
$478.21
$477.46
SPECIFICATIONS
450W HID is replaced by 200w Induction fixture (up to 1000W HID equivalent). 100,000
hour rated lamp, 60,000 hour ballast, 90 CRI, dimmable, instant re-strike, visual acuity
lumens equal to new HID fixture
Induction Lighting
Roadway Photos
HPS on Left, Induction on Right
Induction Lighting
Retrofit Options
23W Induction Lamp, Solar Powered, 20’ Poles
Retrofit options include self-ballasted and remote ballasted from 15W to 200W induction
Commercial Daylighting Systems
Commercial Daylighting
Eliminating electric lighting for six to
ten hours per day
Sensors and Controls
• Automatically control lights based
upon occupancy, daylight
Thermal Flow
Water Cooled Air Conditioning
D/X Split
Systems
MultiZone:
Demand
Buster
Retrofit:
Demand Buster Water-Cooled
Commercial A/C Retrofit
Convert existing roof top air conditioners from high kW demand air-cooled
condenser systems to low kW demand, ultra-efficient water-cooled evaporative
condenser systems. Home Depot Study: 28% Peak Demand, 55% kWH
Reduction.
Membrane ERV
(Energy Recovery Ventilator)
• 71% Sensible AND 64% Latent Heat
Reduction of Fresh Air Entering Building
• Outperforms Dessicant Wheel, with No
Parasitic Power Use
• Can Reduce A/C Sizing by 20 to 30 Percent
• Passive Device - No Moving Parts
• No Condensation - Moisture Exchange
Occurs at Vapor State
• Custom Sizes Available for Any Application
• Effective Efficiency of up to 50 EER!
Eco-Flector Radiant Barrier / Insulating
Window Retrofit
Summer
Side Out
Winter
Side Out
Insulating / Radiant Panel mounts to inside of window with magnetic strip –
reversible for winter heat trapping
Passive Solar Water Heating
Thermosiphon
• Saves 90 to 95% of water
heating costs
• No moving parts
• No storage tank required in
building
• Provides hot water during
power outages
• No freezing, corrosion
• Single most powerful way to
reduce foreign oil dependence
Passive Solar Water Heating
Thermosiphon
Commercial Installation
Photos
Brac Greywater System
•Reuses shower and laundry water to flush toilets.
•Can save 30% of water and sewer costs / usage.
Bathroom #2
Bathroom #1
Washing Machine
Optional if required but not
generally recommended.
Grey Water Recovery Lines
Plumbing Ventilation
Bypass Overflow
Air-ap
Supply
Makeup
Water Line
Tank
Overflow
Service Drain
Trap
Sewer or Septic
Here’s How The System
Works In Your Home
Water from your bath
and shower is
rerouted to the Brac
System for filtration
and disinfection
Bathroom #2
Bathroom #1
Washing Machine
Optional if required but not
generally recommended.
Grey Water Recovery Lines
Plumbing Ventilation
Bypass Overflow
Air-Gap
Supply
Makeup
Water Line
Tank
Overflow
Service Drain
Trap
Sewer or Septic
Here’s How The System
Works In Your Home
When a toilet is
flushed, reclaimed
water is supplied
by the system.
Commercial Brac Grey Water System
(Shower, Rainwater, Laundry, A/C
can Supply Grey Water)
Thank You
We appreciate your taking the time to learn about some of
the latest “Green” commercial options available today.
Please let us know how we can be of assistance.
888-329-2705 / 941-377-9460
www.eco-smart.com