Transcript HVAC
Supplementary Training Modules on GMP Air Handling Systems Heating Ventilation and Air Conditioning (HVAC) Part 2: Components Module 3, Part 2: Components Slide 1 of 20 WHO - EDM Air Handling Systems Purpose of an air handling system Air Handling System Supply Air Module 3, Part 2: Components Production Room With Defined Requirements Slide 2 of 20 Outlet Air WHO - EDM Air Handling Systems Objectives In the following slides, we will study the components of air handling systems in order to: 1. become familiar with the components 2. know their functions 3. become aware of possible problems Module 3, Part 2: Components Slide 3 of 20 WHO - EDM Air Handling Systems Main subsystems Exhaust air treatment Fresh air treatment (make-up air) + Terminal air treatment at production room level Production Room Central air handling unit Module 3, Part 2: Components Slide 4 of 20 WHO - EDM Air Handling Systems Overview components Exhaust Air Grille Silencer Weather louvre Flow rate controller Fan Filter Control damper Heater + Humidifier Prefilter Heating coil Cooling coil with droplet separator Module 3, Part 2: Components Terminal filter Secondary Filter Production Room Re-circulated air Slide 5 of 20 WHO - EDM Air Handling Systems Components (1) Weather louvre To prevent insects, leaves, dirt and rain from entering Silencer To reduce noise caused by air circulation Flow rate controller Automated adjustment of volume of air (night and day, pressure control) Control damper Fixed adjustment of volume of air Module 3, Part 2: Components Slide 6 of 20 WHO - EDM Air Handling Systems Components (2) Heating unit To heat the air to the proper temperature Cooling unit /dehumidifier To cool the air to the required temperature or to remove moisture from the air Humidifier To bring the air to the proper humidity, if too low Filters To eliminate particles of pre-determined dimensions and/or micro-organisms Ducts To transport the air Module 3, Part 2: Components Slide 7 of 20 WHO - EDM Air Handling Systems Problems with components Flow rate controller Blocked Control damper Poorly adjusted, bad pressure differential system Humidifier Bad water/steam quality/poor drainage Cooling battery No elimination of condensed water/poor drainage Filters Incorrect retention rate/damaged/badly installed Ducts Inappropriate material/internal insulator leaking Module 3, Part 2: Components Slide 8 of 20 WHO - EDM Air Handling Systems Air types Fresh air (make-up air) Supply air Exhaust air + Production Room Return air (re-circulated) Module 3, Part 2: Components Slide 9 of 20 WHO - EDM Air Handling Systems Comparing International Cleanroom Classifications 3 Particles / m 0.5µm 1 3,5 10 35 100 353 1.000 3.530 US 209D nonmetric 1 10 100 US 209E 1992 metric M1 M 1.5 M2 M 2.5 M3 M 3.5 EC cGMP Annex I 1997 A, B Germany VDI 2083 1990 UK BS 5295 1989 Japan ISO 14644JIS B 9920 1 1989 0 2 2 1 3 3 2 4 4 3 E or F 5 5 4 G or H 6 6 C 5 J 7 7 D 6 K 8 8 A= unidirectional B= turbulent 10.000 35.300 100.000 353.000 1.000.000 3.530.000 10.000.000 1.000 10.000 100.000 M4 M 4.5 M5 M 5.5 M6 M 6.5 M7 Module 3, Part 2: Components Slide 10 of 20 WHO - EDM Air Handling Systems Filter classes Dust filters Standard Aerosol Coarse Fine HEPA Dp > 10 µ m 10 µ m > Dp > 1 µ m G1 - G4 F5 - F9 Dp < 1 µ m H 11 - 13 EN 779 Standard Module 3, Part 2: Components ULPA U 14- 17 EN 1822 Standard Slide 11 of 20 WHO - EDM Air Handling Systems Classification of filters according to their efficiency F9 Average Efficiency Integral Value Retention in Penetration % 85 0.15 H11 95 0.05 H12 99.5 5x10 H13 99.95 5x10 U14 99.995 5x10 Module 3, Part 2: Components Peak Arrestance Local Value Efficiency Penetration -3 97.5 25x10 -4 99.75 25x10 -5 99.975 25x10 Slide 12 of 20 -3 -4 -5 WHO - EDM Air Handling Systems HEPA or tertiaary filter Primary panel filter Secondary filter Module 3, Part 2: Components Slide 13 of 20 WHO - EDM Air Handling Systems Humidifier Module 3, Part 2: Components Silencer Slide 14 of 20 Heating and cooling units WHO - EDM Air Handling Systems Control damper for air flow Humid room air Adsorber wheel Regeneration air Dry air AHU with fan Variable Speed Controller Humid room air Filter Pressure Gauges Air heater De-humidification Module 3, Part 2: Components Air handling unit Slide 15 of 20 WHO - EDM Air Handling Systems 1 2 3 4 1 2 3 4 Filter Swirl Tightening frame Register outlet Screw fixation for register Module 3, Part 2: Components Type air diffusors with terminal filters Slide 16 of 20 WHO - EDM Air Handling Systems High induction office type diffusor (avoid) Module 3, Part 2: Components Low induction swirl diffusor (preferred) Slide 17 of 20 WHO - EDM Air Handling Systems Regulation of room pressure – pressure differentials concept Room pressure gauges Room pressure indication panel Annex 1, 17.26 Module 3, Part 2: Components Slide 18 of 20 WHO - EDM Air Handling Systems Pressure cascade injectables Protection from micro-organisms and particles Room 1 Room 2 30 Pa 60 Pa Room 3 45 Pa A LF D Air Lock 45 Pa Air Lock B C 15 Pa 30 Pa D Passage Air Lock 0 Pa Annex 1, 17.24, 17.25 Note : Direction of door opening relative to room pressure Module 3, Part 2: Components Slide 19 of 20 WHO - EDM Air Handling Systems Pressure cascade solids Protection from cross-contamination Room 1 Room 2 15 Pa Room 3 15 Pa Air Lock 15 Pa Air Lock Air Lock 30 Pa E Passage 0 Pa 15 Pa Note : Direction of door opening relative to room pressure Module 3, Part 2: Components Slide 20 of 20 WHO - EDM