Eurovent approach - Аирконд

Download Report

Transcript Eurovent approach - Аирконд

ERX-condensing units
Strategic Marketing
1. Concept
2. Product range
3. Combination table
4. Piping length
5. Control possibilities
6. Benefits
7-Jul-15
2
Pair application: ERX + EV + control box + AHU
1. Concept
ERX are R410A inverter units for use with AHU in pair applications
ERX is always used in combination with expansion valve kit (EV kit) and a control box
ERX can not be used with standard Sky Air indoors
DAikin Supply
ERX
R410A
inverter
Sky Air
Outdoor
unit
Field Supply
Refrigerant piping
Air Handling Unit
EV kit
Control box
F1F2
communication
7-Jul-15
3
1. Concept
Multi application : standard VRV outdoors + EV + control box :
Field Supply
DAikin Supply
Standard
VRV
Outdoor
unit
F1F2
communication
Refrigerant piping
Air Handling Unit
EV kit
Control box
VRV
indoor
VRV
indoor
7-Jul-15
4
2. Product range
A. ERX Condensing Units (pair applications)
ERX 100,125,140
(1 phase)
Type
ERX 125, 200
(3 phase)
Voltage
1~ / 220-240V / 50Hz
C/O
3~ / 400V / 50Hz
7-Jul-15
ERX 250
(3 phase)
Product number Material number
ERX100A9V1B
ERX100A9V1
ERX125A9V1B
ERX125A9V1
ERX140A9V1B
ERX140A9V1
ERX125A7W1B
ERX125AW1
ERX200A7W1B
ERX200AW1
ERX250A7W1B
ERX250AW1
5
B. EV Kit and Control Box (Pair and Multi)
Description
EV Kit
7-Jul-15
Product number Material number
AHU inverter EXV-kit 40-50 class
EKEXV50
EKEXV50
AHU inverter EXV-kit 63 class
EKEXV63
EKEXV63
AHU inverter EXV-kit 80 class
EKEXV80
EKEXV80
AHU inverter EXV-kit 100 class
EKEXV100
EKEXV100
AHU inverter EXV-kit 125 class
EKEXV125
EKEXV125
AHU inverter EXV-kit 140 class
EKEXV140
EKEXV140
AHU inverter EXV-kit 200 class
EKEXV200
EKEXV200
AHU inverter EXV-kit 250 class
EKEXV250
EKEXV250
Description
Control
box
2. Product range
Product number Material number
AHU inverter control box pair (z)
EKEXDCBAV3
EKEXDCBA
AHU inverter control box pair (x or y)
EKEXFCBAV3
EKEXFCBA
AHU inverter control box multi (z)
EKEXMCBV3
EKEXMCB
6
3. Combination table
To allow max connection to AHU a range of expansion valve kits
are available for each outdoor
ERX100 :
ERX125 :
ERX140 :
ERX200 :
ERX250 :
Pair
(C/O)
Multi
(C/O)
EV 63 – 125
EV 63 – 140
EV 80 – 140
EV 100- 250
EV125 - 250
Control box
Expansion valve kit
Outdoor unit
EKEXDCBV3 EKEXFCBV3 EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250
P
P
P
P
P
P
100 ERX100A9V1B
P
P
P
P
1 ph
P
P
P
125 ERX125A9V1B
P
P
P
P
P
P
140 ERX140A9V1B
P
P
P
P
P
P
P
125 ERX125A7W1B
3 ph
P
P
P
P
P
P
P
200 ERX200A7W1B
P
P
P
P
P
P
250 ERX250A7W1B
n
n
n
n
n
n
n
n
n
n
5 hp
n
n
n
n
n
n
n
n
n
n
8 hp
n
n
n
n
n
n
n
n
n
n
10 hp
3 ph
VRV outdoor
n
n
n
n
n
n
n
n
n
n
12 hp
n
n
n
n
n
n
n
n
n
n
14 hp
n
n
n
n
n
n
n
n
n
n
16 hp
n
n
n
n
n
n
n
n
n
n
18 hp
P: Pair : Combination depending on AHU coil volume (details will be clarified in TW drawings)
n: Qty determined by connection ration or maximum number of indoor units.
(in combination with VRV-outdoor, the EKEXV -kit is considered as
one of the indoor units)
7-Jul-15
7
4. Piping length
Piping limitations: Pair Application (Sky Air)
EXV-kit
Allowable height
A
B
AHU
E
Daikin
condensing
unit
C
EKEXFCB
EKEXDCB
≤5m
D
AHU
Total system : ≤ 30 m
(Outdoor unit can be
above or below the AHU)
EXV-kit
F
outdoor
DDC
Piping
A
ERX
1 phase
ERX
3 phase
7-Jul-15
100
125
140
125
200
250
Communication
B
length :
5 < A ≤ 50m length : ≤ 5 m
C
≤ 100 m
D
≤ 20 m
E
≤ 20 m
F
Depend
On
DDC
8
4. Piping length
Piping limitations: Multi Application (VRV)
EXV-kit
A
B
Allowable height
E
Daikin
condensing
unit
C
EKEXMCB
D
AHU
1
AHU
≤5m
EXV-kit
1
AHU
n
F
DDC
EXV-kit
n
KIT n
outdo
or
≤5
m
≤ 15
m
Total system : ≤ 40 m
(outdoor unit can be above or
below the AHU)
Indoor 1
Piping
A+B
VRV-III
7-Jul-15
C/O
5~18 HP
Communication
B
Consider length : ≤ 5 m
Same as
indoor
C
VRV
Wiring
policy
D
≤ 50 m
E
F
Depend
≤ 50 m On
DDC
9
5. Control possibilities
3 control systems can be selected :
X: Control of air Temperature (Td, Ts, Tr) with external controller (DDC)  PAIR
Y: Control of evaporating Temperature (Te) with Daikin controller  PAIR
Z: Control of air temperature (Ts, Tr) with Daikin controller  PAIR & MULTI
AHU
Te
Ts
Td
Tr
DDC
7-Jul-15
ROOM
10
5. Control possibilities
Example: Control X (pair)
Control box
EV kit
Te
Ts
Td
Tr
DDC
7-Jul-15
ROOM
11
5. Control possibilities
Example: Control Y (pair)
(Te : 3~8°C)
Control box
EV kit
Te
Ts
Td
Tr
ROOM
7-Jul-15
12
5. Control possibilities
Example: Control Z (pair and multi)
Control box
EV kit
Te
Ts
Td
Tr
Daikin
Controller
7-Jul-15
ROOM
13
5. Control possibilities
System overview
System
Control parameter
Components for control
Type of control
System A: Pair system : ERX
System B: Multi system : VRV
Discharge air control (Td)
suction air control (Ts)
Room air control (Tr)
Evaporating temp control (Te)
DDC (digital controller)
Air thermistor
Air thermistor
BRC1D
KRP4A (remote On/Off)
Supply of parts
Field
Daikin supply
X
Y
Z
O
O
O
O
O
O
-
O
O
-
O
O
O
O
O
Daikin
O (3)
O (4)
Daikin
Daikin
- (2)
-
- (2) (5)
-
field
field
(2) not needed for control purpose (only for service: fault code detection)
(3) required: to be ordered separately as option
(4) possible, but not required: to be ordered separately as option.
(5) Te setting changed by BRC1D (=service tool)
7-Jul-15
EKEXFCBAV3
(customer can
select X or Y)
EKEXDCBAV3 (pair)
EKEXMCBV3 (multi)
14
5. Control possibilities
Control systems
type
Control type X
description
By DDC controller : 0-10 V control
output
Tmeasured
10V
DDC
0~10 V
5V
0V
Tset
-ΔT Tset +ΔT
ΔT = T - T
set
Control type Y
Control type Z
7-Jul-15
PRO
CONTRA
- possibility for Td - higher cost (DDC
control
is needed)
- flexibility in
applications
ΔT
measured
T
measured
Fixed Te
Te = user setting : 3 ~8 °C
using BR1CD + KRP4
(remote on/off)
= Td, Ts or Tr
- Low cost
- no BRC needed
Low cost
no air temp control
- BRC/KRP4
needed
- no possibility for
Td control
15
6. Benefits
Customer benefits
1. Inverter outdoors (ERX or VRV)
2. Pair (ERX) and multi applications (VRV)
3. Extended control systems possible :
• control on evaporating temperature
• control on air temperature (suction / discharge / room temperature)
Compared to Chillers :
1.
2.
3.
7-Jul-15
Same small temperature gradient and control possibilities
No hydraulic components
Better price setting
16
7-Jul-15
17