ClimateMaster 50Hz Product Overview

Download Report

Transcript ClimateMaster 50Hz Product Overview

ClimateMaster
50Hz Product Overview
Where We Have Been and
Where We Are Going…
Current Products
• GC H/V Series
–
R-22
W-W
R-22
R-407C
W-W
R-410A
Models 036, 060, 120
• TMW Series
–
W-A
Models 015 - 70
• GSW Series
–
W-A
R-22
R-407C
Models 006 - 60
• GS H/V Series
–
R-22
Models 006 - 60
• GR H/V Series
–
W-A
Model 100 (kW)
Current Products
• GL H/V Series
–
Console
R-22
R-407C
Vert Stack
R-22
Models 07-19
• 816 Series
–
R-22
Models 03 - 20
• CCE Series
–
Rooftop
Models 072 - 300
• RE Series
–
W-A
R-22
R-407C
Models 10-36
R-407C
GR H/V Series
• Water-to-Air Packaged Units
• Models 006 – 060 (1,5 – 14 kW Cooling Capacity
@ WLHP conditions)
• Extended range operation
– Water Loop or Ground Loop
• Spring-mounted compressors
• CE Mark
• Numerous factory options
R-407C
GSW Series
• Water-to-Water Units
• Models 036, 060, 120 (10, 16, 31 kW Heating
Capacity @ WLHP conditions)
• Extended range operation
– Water Loop or Ground Loop
• Spring-mounted compressors
• CE Mark
• Numerous factory options
R-407C
GL H/V Series
• Large Capacity Water-to-Air Units
• Models 072 – 120 Horizontal (16 – 29 kW
Cooling Capacity @ WLHP Cond.)
• Models 080 – 300 Vertical (17 – 63 kW Cooling
Capacity @ WLHP Cond.)
• Extended range operation
– Water Loop or Ground Loop
• CE Mark
• Numerous factory options
R-407C
CCE Series
• Console Water-to-Air Units
• Models 07 – 19 (1,8 – 3,8 kW Cooling
Capacity @ WLHP)
• Extended range operation
– Water Loop or Ground Loop
• CE Mark
• Numerous factory options
R-410A
TMW Series
• Large Capacity Water-to-Water Units
• Model 100 (100 kW Heating Capacity @ WLHP
conditions)
• Extended range operation
– Water Loop or Ground Loop
• Spring-mounted compressors
• CE Mark
• Numerous factory options
2007 Product Line
R-407C
R-407C
R-410A
R-410A
R-410A
R-410A
R-22
•
•
•
•
•
•
•
•
•
Current GR Series
Current GL Series
Current TMW100 Large Water-to-Water
All New TS Series Water-to-Air Packaged
Units
All New TRC Series Console
All New THW Water-to-Water
Current 50Hz R-22 products
Product Catalog / Literature
ClimaSize in S.I. Units
Refrigerant Focus
All New Products to be Designed
with EarthPure® (R-410A)
EarthPure (R-410A)
• 50/50 Blend of R-32 and R-125
• Offers improved efficiency over R-407c
• Does not separate from its blended state (near
azeotropic)
• Non toxic / non flammable
• Higher operating pressures
• Requires complete product redesign
– Lubricant, burst strength, compressor displacement,
heat exchanger design
EarthPure (R-410A)
• Cannot be Used as a Drop-in for R-22 / R407c
• Environmentally friendly
– ZDP (Zero ozone Depletion Potential)
– Low Global Warming Potential
• Safe
– Low toxicity level (same as R-22)
– Non-flammable
R-410A Operating Pressures
50 - 70% Higher than R-407c
R- 4 1 0 A
R- 4 0 7 c
Suc tion D is c harge Suc tion D is c harge
O perating M ode
pres s ure (bar)
pres s ure (bar)
0 ºC E WT H eating 5 ,5
2 1 ,4
3 ,1
1 3 ,5
1 0 ºC E WT H eating 7 ,6
2 3 ,8
4 ,1
1 3 ,8
1 0 ºC E WT C ooling 9 ,3
1 4 ,1
4 ,8
8 ,6
3 0 ºC E WT C ooling 1 0 ,0
2 4 ,8
5 ,5
1 4 ,5
New Product Line
To Be Complete by the End of 2007
R-407C
GR H/V Series
Currently Available
R-407C
GR H/V Series
• Water-to-Air Packaged Units
• Models 006 – 060 (1,5 – 14 kW Cooling Capacity
@ WLHP conditions)
• Extended range operation
– Water Loop or Ground Loop
• Spring-mounted compressors
• CE Mark
• Numerous factory options
GR H/V Series Efficiencies
•
•
•
•
WLHP EER (30ºC EWT): 3,1 - 4,0
WLHP COP (20ºC EWT): 3,9 - 4,7
GLHP EER (25ºC EWT): 3,6 - 5,3
GLHP COP (0ºC EWT): 3,0 - 3,7
R-407C
GL H/V Series
Currently Available
R-407C
GL H/V Series
• Large Capacity Water-to-Air Units
• Models 072 – 120 Horizontal (16 – 29 kW
Cooling Capacity @ WLHP Cond.)
• Models 080 – 300 Vertical (17 – 63 kW Cooling
Capacity @ WLHP Cond.)
• Extended range operation
– Water Loop or Ground Loop
• CE Mark
• Numerous factory options
GL H/V Series Efficiencies
•
•
•
•
WLHP EER (30ºC EWT): 3,5 - 4,1
WLHP COP (20ºC EWT): 3,9 - 4,9
GLHP EER (25ºC EWT): 4,3 - 5,8
GLHP COP (0ºC EWT): 3,4 - 4,3
TMW Series Large Capacity
Water-to-Water Heat Pump
• Model TMW100
– 100kW Heating Capacity @
WLHP Conditions
• Large capacity / small
footprint
• Dual Copeland Scroll
Compressors
Currently Available
R-410A
TMW Series Large Capacity
Water-to-Water Heat Pump
R-410A
• All service from the front
– Control panel
– Compressors
– TXVs, RVs, filter driers
• Dual isolated compressors
• Coaxial heat exchangers
• Top water connections allow
multiple side by side modules for
large capacity
Front
TMW Series Efficiencies
•
•
•
•
WLHP EER (30/12ºC EWT): 4,3
WLHP COP (20/40ºC EWT): 5,0
GLHP EER (25/12ºC EWT): 5,0
GLHP COP (0/40ºC EWT): 3,2
R-410A
TS Series Product Line
R-410A
TS Series Product Line
• Models 006 – 070 (1,5 – 16 kW Cooling
Capacity @ WLHP Cond.)
• Extended range operation
– Water Loop or Ground Loop
•
•
•
•
Spring-mounted compressors
CE Mark
Numerous factory options
Target Date: September
R-410A
TS Series Product Line
• New black/silver cabinet
• Foil backed insulation in air handler for
improved indoor air quality and ease of
cleaning
• Stainless steel drain pan
• Scroll/rotary compressors
• Horizontal / Vertical Upflow / Vertical
Downflow
TS Series Efficiencies*
•
•
•
•
WLHP EER (30ºC EWT): 4,2 - 4,9
WLHP COP (20ºC EWT): 5,0 - 5,4
GLHP EER (25ºC EWT): 4,9 - 5,6
GLHP COP (0ºC EWT): 3,6 - 3,8
*Estimated based upon lab testing
R-410A
TRC Series Console
Shown with optional fieldinstalled return air grille
R-410A
TRC Series Console
• Models 06 – 18 (1,5 – 5 kW Cooling Capacity @
WLHP Cond.)
• Ductless application
• Removable cabinet
• New electronic controls
• Extended range operation
– Water Loop or Ground Loop
• Black subbase
• Target Date: September
TRC Series Efficiencies*
•
•
•
•
WLHP EER (30ºC EWT): 3,8 - 4,0
WLHP COP (20ºC EWT): 4,5 - 5,1
GLHP EER (25ºC EWT): 4,4 - 4,6
GLHP COP (0ºC EWT): 3,3 - 3,7
*Estimated based upon lab testing
R-410A
THW Series
Water-to-Water
• Models 08, 10, 12 kW Heating
Capacity (GLHP)
• High Temperature (63°C) Output
Even at 0°C Loop Temps
• All New Cabinet
• On-Board Microprocessor Controls
• Target Date: October
Revealed
At Paris
Meeting!
R-410A
THW Series Features
• Compact Size: 650mm wide x 950mm
deep x 1225mm tall
• Hinged front and top panels for easy
service access
• Mitsubishi Scroll Compressor
• Internal “Smart” Controls
• Heating Only Operation
• High COP (4,5 - 4,7 @ 0/35°C)
R-410A
THW Series Features
• Coaxial “Source” Heat Exchanger
– Rugged design
– Open loop capable
•
•
•
•
Brazed Plate “Load” Heat Exchanger
Double Isolation Compressor Mounting
Compressor Discharge Muffler
UltraQuiet Sound Package (standard on
50Hz models)
R-410A
THW Series Features
• Refrigerant Circuit Filter Drier
• Insulated Water / Refrigerant Circuits
• Internal 2-Way Valve for switching
between heating and DHW
• Stainless Steel / Black cabinet or
Appliance White cabinet
• Optional Internal Source/Load Pumps
• Optional Internal Expansion Tanks
Internal
Controls
THW Series
Hinged
Access
Panels
Expansion
Tanks
Muffler
1225
950
650
Mitsubishi
Filter
Scroll Compressor Drier
THW “Smart” Controls
Large (5mm x 5mm)
dot matrix display
user interface
Easy to use menu
choices via 5
buttons
Blue backlight
R-410A
THW “Smart” Controls
•
•
•
•
•
Heating and Domestic Hot Water set points
Outdoor Air temperature reset
Warm Weather Shut Down
Cooling System Enable
Flexible Heating Mode
– e.g. forced air heating in mild weather
• DHW Time Schedule
• Preset Heating Temperatures (Adjustable)
– Radiant Floor or Radiator Applications
R-410A
THW “Smart” Controls
• Two-Stage Operation
– Backup boiler or second unit
• Fault Notification (Red Backlight Screen)
–
–
–
–
–
–
High Pressure
High Compressor Discharge Temperature
Low Pressure
Low Water Temperature
Under/Over Voltage
Bad Thermistor
• Emergency DHW Operation
THW Improvements
Changes made since Paris prototype
unit was built
Increased height
to 1225mm to
accommodate
pumps and provide
better access to
2-way valve
(Paris unit is 1000mm)
Moved electrical
connections from
the left side to the
back
Moved water
connections
from the top
to the back
Coaxial
“Source”
Heat
Exchanger
Brazed Plate
“Source”
Heat
Exchanger
Disconnect
must be turned
off in order to
open access
panels
Full Sheet Metal
Compressor
Enclosure
(next slide)
Extended Range Products
• -7 to 49°C EWT
• TS series / TMW series / THW series
standard with water-refrigerant circuit
insulation
• It’s likely that new 50Hz products moving
forward will be standard as extended range
Future Products…
• Conversion of the rest of the product line to
EarthPure (R-410A)
– GL large capacity water-to-air
– Rooftop
– GR/GC replacement
• For the U.S.: R-22 phase out – January 2010
We Need Your Help…
• Input on New Product Development,
specifically for the European market
• “Wish list”
• Competitor Information
Product Development
Questions…
• Water fittings
– Threaded in “inches?”
• Loop Flow Center (residential)
– Popular in North America
– 3-Way Valves allow purging of air
– Insulated housing helps with condensation at low water
temperatures
– Available with 1 or 2 Grundfos pumps
– Fittings? (electro-fusion, threaded, barbed)
Loop Flow Center
Grundfos
UPS26-99
(1 or 2)
Ground Loop (In/Out)
3-Way Valves
Purge Pump Connections
Heat Pump (In/Out)
Double O-Ring
Fittings
Barbed (inches)
Threaded (inches)
Socket Fusion (inches)
**Electro-fusion (32mm) available**
Product Development
Questions…
• Does direction appear reasonable for European
market?
• Eurovent or ISO?
– Already have ISO certification
• What else should we consider?
Questions?