HOCHIKI PRESENTATION

Download Report

Transcript HOCHIKI PRESENTATION

World Class Leaders in Fire Detection
for over 75 years
HP900
 New Proposed Features
HP900
Main Areas:
Zones in Test
Printouts
Recalibration time
Networking
Time & Date
Expansion of the Test Key
General Discussion
HP900
Zones in Test
This feature will be expanded so that
Multiple zones can be tested
simultaneously.
HP900
Printouts -Event Store
This will allow a selective printout from
the Event Store for a particular loop or a
particular condition i.e. Fires,Faults etc.
This will still allow the complete Event
store to be printed.
HP900
EVENT STORE PRINTOUT
PRINTINGS
HP900
EVENT STORE PRINTOUT
PRINTER
ENABLED
HP900
EVENT STORE PRINTOUT
PRINT EVENT STORE
PRESS ENABLE TO START PRINTING
NOTE
IF ENABLE IS PRESSED
THEN THE COMPLETE EVENT
STORE IS PRINTED
HP900
EVENT STORE PRINTOUT
PRINT ONLY MARKED EVENTS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
OFF
HP900
EVENT STORE PRINTOUT
PRINT FIRES
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT PRE-ALARMS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT FAULTS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT MAINTENANCE WARNINGS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT SPECIAL EVENTS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT SYSTEM EVENTS
NOTE
THE ENABLE/DISABLE KEY
TOGGLES SELECTION
ON
HP900
EVENT STORE PRINTOUT
PRINT EVENTS BY LOOP
PRESS ENABLE TO START PRINTING
NOTE
IF ENABLE IS PRESSED
THEN ALL LOOPS ARE
PRINTED USING THE
PREVIOUS SELECTED OPTIONS
HP900
EVENT STORE PRINTOUT
PRINT EVENTS BY LOOP ALL LOOPS
PRESS ENABLE TO START PRINTING
NOTE
IT IS POSSIBLE TO SELECT
A PARTICULAR LOOP
HP900
EVENT STORE PRINTOUT
PRINT EVENTS BY LOOP 00
PRESS ENABLE TO START PRINTING
NOTE
IT IS POSSIBLE TO SELECT
A PARTICULAR LOOP
HP900
EVENT STORE PRINTOUT
PRINT EVENTS BY LOOP 00
PRESS ENABLE TO START PRINTING
NOTE
IT IS POSSIBLE TO SELECT
A PARTICULAR LOOP
ENABLE
KEY
HP900
Printing Event Store from the Fire Panel
EVENT TIME:
09:00.38 01/01/97
RESET
NODE 01 A:00.019 065/200
EVENT TIME:
09:00.36 01/01/97
EVACUATE
NODE 01 A:00.019 064/200
EVENT TIME:
09:00.11 01/01/97
CHANGED TO ACCESS LEVEL 3
063/200
HP900
Printouts -Event store (Marked
Events)
The events are marked within the event
store, so it is necessary to mark the
events before setting “PRINT MARKED
EVENTS ONLY” to “ON”
HP900
MARKING EVENTS WITHIN THE EVENT STORE
EVENT REGISTER
HP900
MARKING EVENTS WITHIN THE EVENT STORE
EVENT REGISTER SCROLLING
HP900
MARKING EVENTS WITHIN THE EVENT STORE
CHANGING TO ACCESS LEVEL 3
200/200
EVENT TIME
01/01/97
NOTE
THE DISABLE KEY WILL MARK
ALL EVENTS PREVIOUS TO
CURRENT EVENT
09:00.53
DISABLE
KEY
HP900
MARKING EVENTS WITHIN THE EVENT STORE
CHANGING TO ACCESS LEVEL 3
200/200
EVENT TIME
01/01/97
NOTE
THE ASTERIX SHOWS THAT
EVENT HAS BEEN MARKED
* 09:00.53
HP900
MARKING EVENTS WITHIN THE EVENT STORE
CHANGING TO ACCESS LEVEL 2
150/200
EVENT TIME
01/01/97
NOTE
THE DISABLE KEY WILL
UNMARK ALL EVENTS
PREVIOUS TO CURRENT
EVENT
* 09:00.53
DISABLE
KEY
HP900
MARKING EVENTS WITHIN THE EVENT STORE
CHANGING TO ACCESS LEVEL 2
EVENT TIME
NOTE
NOW A BLOCK OF EVENTS
HAS BEEN MARKED BETWEEN
EVENT 150 AND 200.
09:00.53
150/200
01/01/97
HP900
MARKING EVENTS WITHIN THE EVENT STORE
FIRE ALARM
EVENT TIME
NOTE
THE ENABLE KEY WILL
MARK ONE EVENT AT A TIME
112/200
09:00.53
01/01/97
ENABLE
KEY
HP900
MARKING EVENTS WITHIN THE EVENT STORE
FIRE ALARM
EVENT TIME
112/200
* 09:00.53
NOTE
THIS EVENT IS NOW MARKED,
AS WELL AS THE PREVIOUSLY
DEFINED BLOCK
01/01/97
HP900
Printouts -Status
In addition to the current information this
will show if a device is Enabled or
Disabled, if a device is disabled for a
period of time when the automatic
enablement will take place.
Sensor delay time would also be shown.
HP900
STATUS PRINTOUT
PRINTINGS
HP900
STATUS PRINTOUT
PRINTER
ENABLED
HP900
STATUS PRINTOUT
PRINT STATUS BY ZONE
PRESS ENABLE TO START PRINTING
NOTE
IF ENABLE IS PRESSED
THEN THE STATUS OF
ALL THE DEVICES ARE
PRINTED
HP900
EVENT STORE PRINTOUT
PRINT STATUS BY ZONE ALL ZONES
PRESS ENABLE TO START PRINTING
NOTE
IT IS POSSIBLE TO SELECT
A PARTICULAR ZONE
HP900
EVENT STORE PRINTOUT
PRINT STATUS BY ZONE 01
PRESS ENABLE TO START PRINTING
NOTE
IT IS POSSIBLE TO SELECT
A PARTICULAR ZONE
ENABLE
KEY
HP900
Printing from the Fire Panel
09:05.14 01/01/97
OEM-APP- NETWORKING VERSION XX
ZONE 01 NUMBER OF SUB ADDRESS 03
EVACUATE:ON SILEN:ON RESET:ON DEF:ON
UNIT IS DISABLED - ENABLED IN 30 MINS
DUAL SOUNDER CONTROLLER & MONITOR CHQ-B
ADDRESS A:02:064.1
ZONE 01
THRESHOLD 030 PRE-ALARM:ON Z:052 F:179
UNIT IS DISABLED- ENABLED IN 30 MINS
PHOTO SMOKE SENSOR ALE/ALG
ADDRESS A:02:093
ZONE 01
HP900
Recalibration time
At present the sensors are recalibrated
at the time the system is powered up,
this new feature will allow the user to set
the time for recalibration to occur.
HP900
Recalibration
SET CALIBRATION TIME
HP900
Recalibration
CALIBRATION TIME 04:00
NOTE
24 HOUR CLOCK
30 MINUTE STEP
HP900
Recalibration
CALIBRATION TIME 05:00
NOTE
24 HOUR CLOCK
30 MINUTE STEP
HP900
Recalibration
CALIBRATION TIME 04:00
NOTE
24 HOUR CLOCK
30 MINUTE STEP
HP900
Day/ Night mode
This feature will allow each sensor to be
selected to be on Day/Night Mode.
The Day/Night Mode allows reduced
sensitivity during a user defined time
period.
HP900
Networking - Time
Each panel on the network has its own
real time clock, this new feature would
allow the real time clock to be set by any
panel on the network.
Setting the time on one panel, will set
the time on all the panels on the
network.
HP900
Networking - Alerts
This would allow a fire on any panel on
the network to put any other panel on
the network in the Alert condition.
HP900
Networking - Common Zones
This allows each panel on the network to
have zones that are common with other
panels on the network. This allows a
stairwell to be in one zone within a
building when each floor has a separate
control panel.
HP900
Networking - Cause & Effects
This will allow Cause & Effects across
the network, this gives the user the
capability of 99 virtual wires across the
whole network.
HP900
Networking - Cause & Effects
VIRTUAL
WIRE 1
s
s
C&E
TABLE
C&E
TABLE
CONTROL
PANEL 1
CONTROL
PANEL 2
C&E
TABLE
C&E
TABLE
s
VIRTUAL
WIRE 2
s
CHQ-B
PIO
OUTPUT
HP900
Time & Date
This would prevent the control panel
from losing the time and date when
power is removed from the panel.
HP900
Test Key
The function of the Test key will be
expanded to work on the Event Store, so
it will toggle the bottom line between
Event Time/User Text/Device Type and
Fault Code if the Event was a fault.
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
EVENT REGISTER
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
EVENT REGISTER SCROLLING
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
FAULT 11
Z014
EVENT TIME
NOTE
THE TEST KEY WILL TOGGLE
THE BOTTOM LINE.
A:02:093
09:00.53
114/200
01/01/97
TEST
KEY
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
FAULT 11
Z014
A:02:093
114/200
FIRST FLOOR CONFERENCE ROOM
NOTE
THE TEST KEY WILL TOGGLE
THE BOTTOM LINE.
( USER TEXT)
TEST
KEY
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
FAULT 11
Z014
A:02:093
114/200
DEVICE REMOVED FROM SYSTEM
NOTE
THE TEST KEY WILL TOGGLE
THE BOTTOM LINE.
(ENGLISH TEXT OF FAULT)
TEST
KEY
HP900
USING THE TEST KEY WITHIN THE EVENT STORE
FAULT 11
Z014
A:02:093
PHOTO SMOKE SENSOR
NOTE
THE TEST KEY WILL TOGGLE
THE BOTTOM LINE.
(DEVICE TYPE)
114/200
ALE/ALG
TEST
KEY
HP900
General Discussion
 Status of Inputs (Latching/Non-Latching)
 Other requirements