Transcript Read More.... - Diva Eye Institute
QUASAR Technique of Chopping
as devised by
Dr. Dipan Desai Desai Eye Institute & Laser Centre Ahmedabad, India
Stop & Chop Hold & Chop
Current world favourites Combination
QUASAR Technique of Chopping
QU A
QUASAR
S A R Quick & Safe & Reliable
Stop & Chop ( Paul Koch ) Hold & Chop ( Nagahara )
• • • • • • • • •
More Phaco time More fluid exchange Routine 30 degree tip Full diameter nucleus cracked More chance of PC rupture Safe upto grade IV nucl. cats. Provides chopping space May require special chopper for harder cataracts Safer & easier to chop
• • • • • • • •
Less phaco time Less fluid exchange Special 0 degree tip Full diameter & thickness of nucleus cracked Same Safe upto grade III to IV No chopping space Sharp chopper required
•
More technique
Occlusion with High Vacuum
Bury Tip in Nucleus Occlusion with High Vacuum
Final Lateral Forces Applied for Seperation
Final Lateral Forces Applied for Seperation
90 0 Rotation Anti Clockwise
Quasar Phako
is Quick, Safe & Reliable - Good for all Grades of Cataract Quasar2
Quasar II
for removal of Superior Nuclear Half
QUASAR Direct Phaco Chop
Modified and Devised by
Dr. Dipan Desai
(SCULPTING STAGE) Phaco I Settings
•FR – 14 •Vacuum – 30 •Power – 30-50 •Bottle Ht. – 22 inches
Start sculpting at the superior capsulerrhexis margin and go deep into the nucleus downwards and forwards
After embedding the tip into nucleus use Phaco II settings
FR (22-30) Vacuum (100-400) Power in pulse or burst mode
QUASAR PHACO CHOP IS NOW SARAL