Introduction
Quality:
A measure of excellence or a state of
being free from defects, deficiencies and signifi
cant variations.
Power Quality:
Worthiness of electrical power to
consumer devices i.e. not to disturb or damage
appliances and devices.
6/21/2014
Power Quality Improved using DVR
2
Parameters considered
for Power Quality
Voltage Magnitude
Frequency
Wave-shape.
6/21/2014
Power Quality Improved using DVR
3
Effects of Power Quality
Power Quality issues cause business problems such
as:
– Lost productivity, wastage of manpower and
equipments
– Customer and/or management dissatisfaction
– Heavy financial impact
According to Electric Light and Power Magazine,
30% to 40 % of All Business Downtime Is Related to
Power Quality issues.
6/21/2014
Power Quality Improved using DVR
4
Why Power Quality is Big issue
Presently?
– Widespread Usage of Sensitive Loads in
all Applications (PLC based equipments,
Computers and the like)
– For certain devices, a momentary
disturbance may result in
• scrambled data
• interrupted communications
• a frozen mouse
• system crashes and equipment failure
6/21/2014
Power Quality Improved using DVR
5
Power Quality = Voltage Quality
P=V*I * CosΦ
V – Supply Voltage – Always Constant
I and CosΦ – Depends on the nature of load
6/21/2014
Power Quality Improved using DVR
6
Power Quality / Voltage Quality
Issues
• Voltage Sag
• Voltage Swell
6/21/2014
Power Quality Improved using DVR
7
Power Quality / Voltage Quality Issues
• Interruption
• Harmonics
6/21/2014
Power Quality Improved using DVR
8
Major Power Quality (PQ) Problems
Outages,
6%
Spikes, 7%
Swells,
Sags, 56%
31%
Source: EPRI, 1994
6/21/2014
Power Quality Improved using DVR
9
Importance of Voltage Sag
Textile Industry
Plastics Industry
Glass Industry
Process Industry
Semiconductors
Rs.60k
Rs.600k
Rs. 60L
Rs6 Cr
Rs. 60 Cr
Losses per Voltage Sag Event
6/21/2014
Power Quality Improved using DVR
10
PQ Improvement Techniques
Series Compensation
DVR
SSC
Shunt Compensation
STATCOM
TCSC
Series and Shunt Compensation TCSC
UPFC
6/21/2014
Power Quality Improved using DVR
11
Dynamic Voltage Restorer (DVR)
Series compensation device
Protects sensitive electric loads
from PQ problems
Implemented
through
power
electronic controllers that use
voltage source converters (VSC).
6/21/2014
Power Quality Improved using DVR
12
Block Diagram of DVR
6/21/2014
Power Quality Improved using DVR
13
Operation of DVR
a
VaN
N
6/21/2014
Power Quality Improved using DVR
14
Twentyseven Level Inverter
6/21/2014
Power Quality Improved using DVR
15
Questions???
6/21/2014
Power Quality Improved using DVR
16
6/21/2014
Power Quality Improved using DVR
17