Data Converter20130306

Download Report

Transcript Data Converter20130306

KX-NS1000 Version 2

Database Converter

(NS1000 Off line mode V2.0)

The database converter is a part of application in NS off-line programming software.

Introduction

This document explains ‘Database Converter’, and is composed of the following chapters.

Chapter 1 Overview Chapter 2 Specifications Chapter 3 Data Conversion Chapter 4 Appendix For further information about feature implementation and specifications, refer to the following manuals.

“Installation Manual“

/

”Feature Guide“ / “Getting Started” • Microsoft, Internet Explorer, Outlook, Windows, Windows XP, Windows Vista, and Windows 7 are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

• Mozilla and Firefox are registered trademarks of the Mozilla Foundation.

• All other trademarks identified here in are the property of their respective owners.

• Microsoft product screen shots reprinted with permission from Microsoft Corporation.

Table of Contents

Chapter 1) Overview

1-1 Converter Overview 1-2 Support Features

3) Data Conversion

3-1 Procedure of Conversion 3-2 Suffix Code 3-3 Result of Converting

2) Specifications

2-1 Target of PBX 2-2 Conversion item of programming 2-3 Available Converting Patterns 2-4 Unavailable Converting Patterns 2-5 Table of item not converted 2-6 Unavailable Cards

4) Appendix

Chapter 1 Overview

1-1. Converter Overview

The NS off-line programming tool provides legacy database converter feature.

It can convert the system data of NCP/TDE/TDA series PBX into the data for NS1000.

UPCMC Menu [PBX Replacement] TDA100/200 TDA600 DSYS DLSYS TDA Conversion TDE100/200 DMSYS TDE600 DGSYS NCP500/1000 DBSYS TDE/NCP NS-Off line tool (V2.0) Menu [Convert] Conversion Result DCSYS report Not support to convert via Web-MC (On-line).

NS1000 NS1000 is overwritten in new DCSYS. The data of TDA should convert into the data of TDE in UPCMC. The data file name of TDA/TDE/NCP are different depending on each device.

Activation key is not transferred at the converting database.

1-2. Support Features (1)

(1) Platform Replacement (TDE/NCP --> NS1000) Legacy database converter can convert to NS1000 setting data from Legacy PBX setting data.

The target data of conversion is the data of only IP Trunk and IP terminal.

(The data of the physical IP-GW card is not converted.)

IP Trunk V-IPGW16,V-SIPGW16 IP GW4,16 It’s not supported.

IP Trunk V-IPGW16,V-SIPGW16 TDA/TDE/NCP NS1000 TDA/TDE/NCP not used IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4 IP-EXT16 (Physical card) IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4 The data of the physical IP-EXT card is converted to V-IPEXT card.

OPB card and any card on OPB card are not supported to convert.

1-2. Support Features (2)

(2) Platform as Legacy Gateway data (TDE/NCP - -> NS1000 + Legacy GW) Legacy database converter can be conversion to the setting data for using existing PBX as legacy gateway.

(The data related to IP is converted like case “(1) Platform Replacement”.)

Legacy Trunk IP Trunk V-IPGW16,V-SIPGW16 IP GW4,16 It’s not supported.

IP Trunk TDA/TDE/NCP Legacy Trunk NS1000 STACK-M IP Trunk V-IPGW16, V-SIPGW16 STACK-S DPT/SLT IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4 IP-EXT16 (Physical card) DPT/SLT conversion PS can be used without re-registration. IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4

Chapter 2 Specifications

2-1. Target series of PBX

The following table shows target series of PBX and the version number that can be converted. The file name of TDA/TDE/NCP are different depending on each device.

Series of PBX NCP500/1000 TDA100/200 TDE100/200 TDA600/620 TDE600/620 Version number Ver. 6 Ver. 5 Ver. 6 Ver. 5 Ver. 6 Data File name DBSYS DSYS DMSYS DLSYS DGSYS [Note] The TDA database file has to be converted into DGSYS or DMSYS of TDE by using data replacement application on PCMC before using the legacy database convertor.

New program items added in NS1000 are filled by the default value. All data of numbering plan are switched to originated (New DCSYS) data since the default values are different between NS1000 and other PBXs.

New setting of dial plan added in NS1000, which is not in legacy PBXs, are filled with BLANK.

2-2. Conversion of programming item (1)

Mode : Platform Replacement (TDE/NCP ->NS1000) The following table shows which programming items can be converted.

Originated PBX NCP500/1000 TDE100/200/600 TDA100/200/600 Extension *1,*2 IP Extension PS/IP-CS IP Extension of IP-EXT card Trunk *3,*4 IP Trunk Programming items Numbering Plan COS DDI/ DID Yes Yes Yes Group SSD PSD Yes CTI Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes *1: Include Extension number, Extension name, FF key data *2: Only support IP Extension and PS/IP-PS *3: Include Trunk number *4: IP trunk of IP-GW card is not supported.

2-2. Conversion of programming item (2)

Mode : Platform As Legacy GW Data (TDE/NCP ->NS1000+Legacy GW) The following table shows which programming items can be converted.

Programming Items Originated PBX Convert to Extension *1 Trunk *2 Numbering Plan COS DDI/ DID Group SSD PSD NCP500/1000 TDE100/200 TDA100/200 TDE600 TDA600 (Basic shelf) TDE600/620 TDA600/620 (Basic shelf & Expansion shelf 1) Legacy GW1 Legacy GW1 Legacy GW1+GW2 +GW3+GW4 All Ext.

All Ext.

All Trunk All Ext.. All Trunk All Trunk Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes *1: Include Extension number, Extension name, FF key data *2: Include Trunk number CTI Yes Yes Yes

2-3. Available Converting Patterns (1)

Pattern 1 (Replacement : Only IP)

TDA/TDE/NCP NS1000

Pattern 2 (Included Legacy gateway)

TDA/TDE/NCP NS1000 Legacy Gateway1

Port of Gateway1 Port of Gateway2

The existing PBX as Legacy gateway should be connected with Legacy GW1.

Pattern 3 (Multi cabinets)

Shelf 2 TDE620 TDE600 Shelf 1 NS1000 The data of TDE/TDA multi cabinets can be converted to NS1000 data.

Shelf 1 Shelf 2 TDE 600 TDE 620 Legacy Gateway1 Legacy Gateway2

2-3. Available Converting Patterns (2)

Pattern 4 (4 cabinets)

TDA600/620 or TDE600/620 Shelf 4 One Look Networking Master Slave NS1000 Legacy Gateway1 Legacy Gateway2 Legacy Gateway1 Shelf 3 NS1000 Legacy Gateway2 Shelf 2 Shelf 1 Shelf 1 Shelf 2 Shelf 3 Shelf 4

The shelf location is fixed.

This tool supports the data conversion to Legacy gateway which is connected with the master NS1000.

2-4. Unavailable Converting Patterns (1)

Pattern 1 (Multi system)

TDA/TDE/NCP DCSYS NS1000 DBSYS Legacy Gateway1 Legacy Gateway2 DBSYS One Look Networking Master Slave DCSYS Legacy Gateway1 Legacy Gateway1 This tool doesn't support data conversion of the multi PBX system. (This tool can not merge multi PBX system data.)

2-4. Unavailable Converting Patterns (2)

Pattern 2 (Slave system)

TDA/TDE/NCP One Look Networking Master Slave DBSYS DCSYS Legacy Gateway1 This tool doesn't support the data conversion connected with the slave NS1000.

Pattern 3 (Port of Legacy Gateway2)

TDA/TDE/NCP DCSYS DBSYS Legacy Gateway2 This tool doesn't support the data conversion connected with the Legacy GW2.

2-5. Table of item not converted (1)

The converted value is indicated in right column.

Function Time Service Switching Mode Time Setting

Time Table) Timed Reminder Extension Dial Lock Remote Extension Dial Lock Call Charge data Not Ready (Manual Wrap-up) Mode On / Off LCS On/Off Hospitality Features

Check In/Out Not Ready/Cleaned Up

Auto Answer Absent Message Last Number Redial Changing the Log-in/Log-out Status of Extensions Value (after the converted) The default setting Clear Clear Unlock Unlock Clear Off Off Clear The default setting The default setting Clear Clear

2-5. Table of item not converted (2)

Function Message Waiting Incoming Call Log Call Charge Outgoing Call Log TAM Log OGM Call Forwarding (FWD)/Do Not Disturb (DND) Settings Traffic data Verification Code PIN Lock state Verification Code PIN Lock counter Password Lock counter for Remote System Programming Major/Minor alarms Error Log Wake-up Call Value (after the converted) Clear Clear Clear Clear Clear Clear Off Clear Unlock Clear Clear Clear Clear Clear

2-6. Unavailable Cards

Following components can not be used with Legacy-GW. These data is deleted.

Symbol RMT MEC DSP4/16/64 CTI-LINK IP-EXT16 IP GW4/IP-GW4E IP-GW16 MSG4 ESVM2/4 TDA0196 Model TDA0105/TDE0105 NCP1104/TDE0110/TDE0111 TDA0410 TDA0470 TDA0480/TDA0484 TDA0490 TDA0191 TDA0192/TDA0194 Description Analogue Modem for Remote Maintenance Memory Expansion Card VoIP channel card 4ch/16ch/64ch CTI Link Card 16-Channnel VoIP Extension Card *1 4-Channnel VoIP Gateway Card 16-Channnel VoIP Gateway Card 4-Channel Message Card 2/4-Channel Simplified Voice Message Card CLCOT8 * CLCOT8E * TDA1180 TDA1186 8-Port Analogue Trunk Base Card w/ Caller ID 8-Port Analogue Trunk Daughter Card w/ Caller ID MCSLC24 TDA1178 24-Port Single Line Telephone Card MCSLC16 TDA1176 16-Port Single Line Telephone Card *1: The data of IP extension is taken over to a virtual extension card. Regarding the deleted data is displayed on the results report.

Chapter 3 Data Conversion

3-1. Procedure of Conversion (1)

After these selection, some of mandatory system setting need to be programmed, then DCSYS file for NS1000 is created.

NS-Off line tool (V2.0) Menu [Convert] (1) Click. The following screen is opened.

(2) Converter type needs to be selected from the following 2 types at initiation of converter application.

1) Replacement ( →NS1000) 2) Converting ( →NS1000+Legacy Gateway) (3) Enter the data to convert.

DMSYS TDE100/200 or DGSYS or TDE600 DBSYS NCP500/1000

3-1. Procedure of Conversion (2)

Depending on the data to convert, the following screen will be displayed.

For NCP, TDA/E100, and TDA/E200 For TDA/E600, and TDA/E620 when the slave is connected Click. [Next]

3-1. Procedure of Conversion (3)

Parameter and operation are completely the same as Easy Setup wizard.

1 Setup Master Unit A part of region should change the setting. Please refer to ‘3-2 Suffix Code’.

IP addresses, type of registration and password, etc programmed on TDE/NCP are displayed by default.

Converting time is estimated to take with in 10 seconds

3-1. Procedure of Conversion (4)

2 Setup Slave Unit

(when the slave is connected) This operation is required in the case of source database file contains an more than 3 expansion unit setting of TDA600/620 or TDE600/620.

After converting the master unit, the ‘setup screen of slave unit’ is displayed automatically.

IP addresses, type of registration and password, etc programmed on TDE/NCP are displayed by default.

Converting time is estimated to take with in 10 seconds

3-1. Procedure of Conversion (5)

When the conversion of data is completed, the report of the result is displayed.

Click. [Save] Activation key is not transferred at the converting database

3-1. Procedure of Conversion (6)

The new file name should be 'DCSYS‘.

Three steps can be selected.

After selection, click [OK].

1. Finish DCSYS The ‘DCSYS’ has to input. And, converted DCSYS is downloaded.

Click. [Next] 2. Connection Online Mode 3. Open Offline mode

When you want to edit the data.

When you want to install the data to NS1000.

(Go to next page)

3-1. Procedure of Conversion (7)

Please install the 'converted DCSYS' to NS1000 with online mode.

Menu [Utility] - [2.File] - [1.File Transfer PC to PBX] C:\Documents- - - -DCSYS Select the file name.

And click [Execute]. Next This screen is displayed. Click [OK].

At last, the reset operation is necessary.

Menu [System Control] - [4.System Reset]

3-2. Suffix Code

Please change the setting to the area shown in the following tables. Legacy gateway

Suffix code NE BX RU Area CE BX RU

NS1000

Suffix code NE BX RU UC Area CE TR BX TW RU UC In area other than this table, the change is unnecessary. Note Eastern Europe Turkey Other Taiwan Russia Ukraine

Reference

3-3. Result of Converting (1)

The following results are displayed when the data conversion is completed.

It might be effective help to make the new Configuration of NS1000. These contents are examples.

Report of conversion result (examples) Complete of Database conversion Original file : PSN_TDE600 Original PBX : TDE600 Following Recommended A.K.

One-look Networking Up to 100 IP Phone Capacity Recommended AK is displayed. Deleted Card Shelf1,Slot01 : IP-EXT16 Both the deleted extension number and the deleted CO number are described. Deleted Extension 6780, 6781, 6782, 6783, 6784, 6785, 6786, 6787, 16788,16789,16790,16791, 792, 793, 794, 795 Shelf1,Slot02 : IP-GW16 Deleted CO line 007,008,009,010,011,012,013,014, 015,016,017,018,019,020,021,022 Shelf1,Slot01-01 : OPB3 - MSG4 OPB card and any card on OPB card are not supported to convert.

Reference

3-3. Result of Converting (2)

Report of conversion result (examples) Deleted Card Shelf4,Slot15 : MCSLC16 Deleted Extension 10001,10002,10003,10004,10005,10006,10007,10008, 10009,10010,10011,10012,10013,10014,10015,10016 Deleted Remote Access Device Change 599 : MODEM 699 : ISDN Remote Two IP-EXT16 cards were integrated into one V-IPEXT32 card. IP-EXT16 : Shelf 1 ,Slot01 -> V-IPEXT32 : Site01,Slot47 IP-EXT16 : Shelf 2 ,Slot01 -> V-IPEXT32 : Site01,Slot47 IP-EXT16 : Shelf4,Slot01 -> V-IPEXT32 : Site02,Slot47 Change SVM-Voice Msg Extension No. to UM channel No.

591 : SVM-Voice Msg1 -> 5101 : Master UM channel 1 592 : SVM-Voice Msg2 -> 5102 : Master UM channel 2 New Assigned 5103 : Master FAX Extension number

Chapter 4 Appendix

Supported PBX Model

Application model

KX-NS1000 allows connecting the following system as legacy gateway system.

It means “The data of the application model is convertible “.

Legacy Platform's

TDA TDE NCP

Models

15 30/50 100/200 600/620 100D 100/200 600/620 500/1000 500 express

Yes / No

No No Yes Yes No Yes Yes Yes Yes

Change of version of DSYS from V4 to V6

Change of version of DSYS

Please use version 6 or late of UPCMC.

DGSYS

Example

DGSYS

V6

DGSYS

Suffix Table (1)

Suffix Code and Area table.

Suffix code NE NE NE E GR AL NZ NE NE NE NE NE NE NE NE NE NE NE Area SL CE CE E GR AL NZ G BL DK FI FR JT NL NO PT SP SE Suffix code NE NE NE UK NE AL AL NE NE NE NE NE NE NE NE NE NE NE Area SL CE TR UK GR AL NZ G BL DK FI FR JT NL NO PT SP SE Note Germany. Austria Belgium/Luxembourg Denmark Finland France Italy Netherlands Norway Portugal Spain Sweden Switzerland Eastern Europe Turkey UK Greece Australia New Zealand Please select the Area on the converter.

Suffix Table (2)

Suffix Code and Area table. Suffix code HK ML SN CN M BX BX BX BX AG C CE RU RU BR Area HK ML SN CN M BX BX BX SA AG C CE RU RU BR Suffix code XE XE XE BX M BX BX BX BX AG C NE RU UC BR Area HK ML SN BX M BX TW BX SA AG C CE RU UC BR Note Hong Kong Malaysia Singapore Others USA Other Taiwan BX South Africa Argentina Canada Eastern Europe Russia Ukraine Brazil Please select the Area on the converter.

Thank you !

The END