Transcript PI Medical

Quality Control
True Precision. PTW.
Quality Control
Connect ...
} C
E marked, class IIb certified diagnostic dosimetry system, fully
compliant with IEC 61674 for acceptance testing and quality control measurements on RAD, FLU, DENT, CT and MAM X-ray units
} A
llows to connect either a semi-conductor detector (R/F/D or
MAM), CT ionization chamber (100 mm or 300 mm long) or a
shadow-free ionization chamber (6 cm³ or 75 cm³) for no interferences with the AEC
} C
ombined with the NOMEX® multimeter, a single exposure
simultaneously captures dose, dose rate, dose per pulse, pulses,
frequency, irradiation time, tube voltage, total filtration, half
value layer and waveforms for both kV and dose rate
} Provides for automatic air density correction
CT Ionization Chamber,100 mm
NOMEX® Multimeter
R/F/D Diagnostic Detector
Shadow-Free Ionization Chamber, 6 cm³
} Stores the last measurements and allows data and waveform
export as XLS, XML or CSV file via USB or Bluetooth®
} S
oftware menu available in different languages (Chinese, English,
French, German, Italian, Japanese, Portuguese, Russian, Spanish)
H e a lt h p h y s i c s
nuclear medicine
diagnostic radiology
r a d i at i o n t h e r a p y
Technical Data
Standard
Measuring ranges
Current
Resolution
Charge
Resolution
Irradiation time
Pulse
Pulse width
Frequency
Temperature
Relative air humidity
Air pressure
IEC 61674, DIN EN 61010-1, IEC 61326-1
2 pA … 20 µA, < 2%
20 fA
2 pC … 200 mC, < 2%
4 fC
1 ms … 9999 s, ± 1 ms
(0 … 9999), ± 1 pulse
(0.1 … 500) ms
(0.2 … 500) Hz
(10 … 40) °C
(10 … 80) %, max. 20 g/cm³
(700 … 1060) hPa
The respective measuring range depends on the detector connected,
e.g. PTW R/F/D detector, MAM detector and CT ionization chamber:
Air kerma rate R/F/D
50 nGy/s … 500 mGy/s
Air kerma R/F/D
50 nGy … 5 kGy
Resolution
0.5 nGy/s
Air kerma rate MAM
130 nGy/s … 1.3 Gy/s
Air kerma MAM
130 nGy … 13 kGy
Resolution
1 nGy
Air kerma rate CT 150 µGcm/s … 1.5 kGycm/s
Air kerma CT 150 µGcm … 15 MGycm
Resolution 1.5 µGcm/s
Energy dependence
≤±5%
PC interface
Outer dimensions
Weight
Bluetooth® 2.0, USB 2.0 Full-Speed
160 mm x 150 mm x 40 mm
550 g, incl. batteries
Ordering information
[L981816] NOMEX® dosemeter
measures dose, dose rate, dose/pulse, pulses, time, kV, TF and HVL depending
on the detector connected. NOMEX® multimeter, semiconductor detectors
or ionization chambers can be connected. Includes software and a transport
case.
[L981814] NOMEX® set
for measurements in R/F/DENT/CT/MAM. Includes NOMEX® dosemeter,
NOMEX® multimeter, NOMEX® software, USB cable (2 m, 5 m), transport
case. Measures dose, dose rate, dose/pulse, pulses, time, kV, TF, HVL.
External semiconductor detectors or ionization chambers can be connected.
©PTW. All Rights Reserved. D909.139.01/00. Effective 2013/02.
Previous specifications are void.
www.ptwnomex.com
USA | Latin America | China | Asia Pacific | india | UK | France | Iberia | germany
Knowing what
responsibility means