BLG9-IMDdigit 2016 UK fn

Download Report

Transcript BLG9-IMDdigit 2016 UK fn

High Frequency
Quality Protection for Small Servers, and Workstations & PCs
Line interactive design
Boost and buck AVR (Auto voltage regulation)
Fully digitalized microprocessor controlled
Energy saving function (UPS green mode)
50/60Hz frequency auto sensing and selection
Cold start function (DC power on)
Lightning and surge protection
Short circuit and overload protection
Advanced battery management (ABM technology)
Smart RS-232 communication port
Tel/Modem internet surge suppression
Automatically charging when UPS off
History record of power failure events
Back up, on-line, battery status, power status display by software
Schedule shutdown & reboot
IMD Digit Series
BLG Series
Uninterruptible power supply LINE INTERACTIVE STEP WAVE
Security and an environmental close-up
(Global warming, CO2 reduction)
Conformità alle direttive 89/336/CEE e 72/23/CEE e marcatura
Conformity to the directives 89/336/CEE and 72/23/CEE
.
marking.
The company reserves the right to change the specifications of its products without prior notice and such change would render the pubblications inaccurate.
Rev.:2-2016
ISO 9001
Technical Characteristics
SPECIFICATION
Models
Power (VA)
Power (W)
IMD 700 Digit IMD 1000 Digit
BLG 9
600
360
IMD 1500 Digit
IMD 2000 Digit
AVR - LINE INTERACTIVE
INPUT
Voltage (Vac)
Frequency (Hz)
230 +/- 25%
50-60 +/- 10% (autosensing)
All trademarks are
property of their
respective companies
OUTPUT
Voltage on battery (Vac)
Voltage Regulation
Sine wave
Frequency (Hz)
Socket
230
5% (battery mode)
STEP-WAVE
50 - 60 +/- 0,5 Hz (battery mode)
BATTERY
Type
Recharge time
Protection Back-up Time
Protection
Sealed,maintenance-free lead acid batteries with 3-6 years typical lifetime
6 hours (to 90% of full capacity)
5/7 minutes
4/6 minutes
Auto discharge protection
PROTECTION and FILTER
Overload
Short circuit
Spike Protection Unit Input
Modem / LAN
NO
110% for 60 seconds - 130% for 3 seconds
With fuse
480 Joules, 2 ms
surge protection
Certifications
STANDARDS
EN 50091-1
EN 50091-2
IEC 801-5
Security
Conformity EMC
Surge capability
INTERFACE
Hardware
NO
Software
NO
LCD and LED bar
ENVIRONMENT
3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 degrees?°#
Ambient operation
Dimension (WxOxH mm) 97x320x135
Net Weight (kg)
6,8
2
CONNECTIONS
CONNESSIONI
BLG 9
1
5
4
3
6
2
di segnalazione
11.- LED
Indicators
Led and Alarm
2 - funzionamento
on/off switch / allarmi
ON signal
/ OFF from net
32.- Pulsante
Input power
da from
rete battery
43.- Funzionamento
Input power signal
54.- Funzionamento
Output overloadda batteria
uscita
65.- Sovraccarico
Audible alarminwhen:
Allarme
6.
- Ups
takesonoro:
power from battery
- Funzionamento da batteria
- low battery level
- Batteria in fine scarica
- overload
- Sovraccarico
1
di socket
uscita
11.- Prese
Output
alimentazione
22.- Presa
Inputdisocket
SINOPTIC AND COMMANDS
IMD DIGIT SERIES
1 - on/off
switch
serie
IMD test
Digit
IMD
Digitindicator by led
2 serie
- Input
signal
3 - Load power from battery
indicator by led
4 - Output overload indicator by
led and audible alarm
5 - Battery charge level indicator
on display bar
6 - LCD display, with output
voltage indication
CONNECTIONS
1 - USB interface
2 - TEL/LAN protection filter
3 - Input socket
4 - Output UPS socket
5 - Output socket filtered
Powergen S.r.l.
Via XXV Aprile, 5 - 52010 Corsalone - Chiusi Della Verna (Arezzo)
phone +39 (0) 575 531015 - Telefax +39 (0) 575 511891
[email protected]
powergen-borri
www.batterychargerpowergen.eu
The company reserves the right to change the specifications of its products without prior notice and such change would render the pubblications inaccurate.
Rev.:2-2016
SINOPTIC
ANDECOMMANDS
SINOTTICO
COMANDI