Transcript ppt
GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 GLAST Large Area Telescope: Gamma-ray Large Area Space Telescope TKR Updates at SLAC Hiro Tajima (SLAC) Johann Cohen-Tanugi (SLAC) TKR [email protected] 650-926-3035 Hiro Tajima, TKR Updates at SLAC 1 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 OUTLINE • End-toEnd TOT Calibrations – Summary of TOT calibration sequence. – Charge scale distribution for 8-tower data – Comparison between MC and data. • TOT distribution • Angle dependence of TOT peak • Efficiency trending. Hiro Tajima, TKR Updates at SLAC 2 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 End-to-End TOT Calibration Summary • TACK timing. – done. • GTFE charge injection scale. – done. • GTFE Threshold. – done. • TOT gain parameter. – Correct thresholds were not used due to a bug in the TKR script • Fixed before 8-tower tests. – Column and row number were swapped due to a bug in LATTE tower mapping. • Fixed before 8-tower tests. • TKR recon. – Wrong scale was used for “charge per MIP” parameter. Hiro Tajima, TKR Updates at SLAC 3 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 Charge Scale after TOT Calibrations • Definition of charge scale. – Plot ratio 4.92/peak. (4.92 fC is expected for MIP) (should be 1.0 if calibration is correctly applied.) Before charge scale calibration 8-tower data (after fixes) 6-tower data (after charge scale calibration) Wrong “fC per MIP” parameter Johann Tower row and column Numbers swapped for TOT gain parameter Hiro Tajima, TKR Updates at SLAC 4 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 Data/MC Comparison: TOT Distribution • Fit parameters for data and MC are very similar – Gaussian convolved Landau distribution function – Peak at 4.91 : 4.92 fC MC – Landau width at 0.375 : 0.344 – Gaussian sigma at 0.69 : 0.69 Data TOT charge (fC) TOT charge (fC) Hiro Tajima, TKR Updates at SLAC Johann 5 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 Angle Dependence of TOT Peak TOT peak (fC) • Incident angle dependence of TOT peak. MC before angle correction: 10% effect MC MC MC after angle correction: <1% effect cos cos DATA 8-tower data after angle correction: ~1% residual effect Johann cos Hiro Tajima, TKR Updates at SLAC 6 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 Tower Efficiency Trending Trend tower efficiency during I&T phase – All I&T data sets are analyzed by the latest TkrRecon. – FMB and FM1 shows consistent (but tiny) downward trend. • 0.06% inefficiency corresponds to ONE strip. Efficiency Trend 0.06% 0.04% Efficiency change • TkrFMA TkrFMB TkrFM1 TkrFM2 TkrFM3 TkrFM4 TkrFM5 TkrFM6 0.02% 0.00% -0.02% -0.04% -0.06% Johann -0.08% 2TWR 4TWR 6TWR 8TWR Test phase Hiro Tajima, TKR Updates at SLAC 7 GLAST LAT Project LAT Instrument Analysis Meeting– Aug 29, 2005 Conclusions • Calibration procedure for TOT/threshold/charge scale is demonstrated end-to-end. – Improvement can be made for angle dependence of TOT peak in data. – TOT distributions in data and MC are very similar. • Started tower efficiency trending. – No major drop of efficiency observed. – Tiny and consistent downward trend in FMB and FM1. • Plan to trend more parameters. – # of bad channels, thresholds, TOT parameters … Hiro Tajima, TKR Updates at SLAC 8