Predicting the Intelligibility of Cochlear-implant Vocoded
Speech from Objective Quality Measure(10)
Department of Electrical Engineering, The University of Texas at Dallas, Richardson, Texas75083, USA
Chairman:Hung-Chi Yang
Presenter: Yu-Kai Wang
Advisor: Dr. Yeou-Jiunn Chen
Date: 2012.12.12
Material and Methods


2.3 Signal processing
The stimuli were presented in two signal processing
conditions.



Tone-vocoder.
EAS-vocoder.
The first processing condition (tone-vocoder) .





To simulate eight-channel electrical stimulation.
Eightd-channel sinewave-excited vocoder.
Through a pre -emphasis filter (2000-Hz cutoff) with 3 dB/octave
roll-off.
Band-passed into eight frequency bands btween 80 and 6000 Hz.
Sixth-order Butterworth filter.
Results

Figure 1 shows sentence intelligibility scores


54 vocoded test conditions of English sentences .
20 vocoded test conditions of Mandarin Chinese sentences.