Transcript CV-1C
750 V 70C THW 0.6/1 (MEA kV CVTYPE A) PVC INSULATED, SINGLE-CORE 1 CORE - CROSSLINKED POLYETHYLENE POWER CABLE ° BANGKOK CABLE 750 V 70 C PVC THW BANGKOK CABLE 0.6/1 kV CV Construction Construction 1 1 2 2 3 Reference Standard : 1. Conductor : Solid or concentric stranded annealed copper Reference Standard : 1. Conductor : Concentric stranded or Compacted stranded 2. Insulation : Polyvinylannealed chloride (PVC) TIS 11-2531, TABLE 4 IEC 60502-1 copper Red, Blue, Green or other 2. Insulation White, Black, : Cross-linked polyethylene (XLPE),colour Natural colour Classification 3. Sheath : Polyvinyl chloride (PVC), Black colour Classification Maximum conductor temperature Maximum conductor temperature: 70C: 90C Maximum circuitcircuit voltage : 750 :V1,000 V Maximum voltage AC testACvoltage : 2,500: 3,500 V V test voltage B Application Application For building wiring,purpose installation on distribution insulator orinindry raceway, dry location. For general power or wet location, installation exposed in conduit or duct or direct burial in ground. Conductor Thickness Thickness Overall Overall Current rating Conductor Thickness Insulation Cable DC. Insulstion Current Cross- CrossNo. & dia. Diameter of diameter resistance rating weight of of diameter conductor resistance in free air direct burial No. of Diameter in free air sectionalsectional of wireswires insulation at 70 C insulation sheath resistance at 20C at 40C in ground area at 40C area at 20C ambient at 30C ambient mm2 0.5 1 1 1.5 1.5 2.5 2.5 4 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 No./mm mm mm mm mm mm mm mm mm2 (Max.) (Min.) (Approx.) (Nominal) (Nominal) (Approx.) 1/0.80 0.80 0.8 3.0 1.5 1/1.13 7 1.56 0.7 0.8 1.4 6.5 1.13 3.3 2.5 7/0.40 7 2.01 0.7 0.8 1.4 7.0 1.20 3.5 1/1.38 1.38 0.8 3.6 4 7 2.55 0.7 1.4 7.5 1.50 3.8 6 7/0.50 7 3.12 0.7 0.8 1.4 8.0 1.78 4.0 10 1/1.78 6 3.72 0.7 0.8 1.4 8.5 7/0.67 2.01 0.8 4.3 16 1/2.25 6 4.69 0.7 0.9 1.4 9.5 2.25 4.8 25 7/0.85 6 5.90 0.9 1.4 11.5 2.55 0.9 5.2 35 7/1.04 6 6.95 0.9 0.9 1.4 12.5 3.12 5.8 50 7/1.35 6 8.33 1.0 1.1 1.4 14.0 4.05 7.2 5.10 8.4 70 7/1.70 12 9.73 1.1 1.1 1.4 15.5 6.42 10.5 95 7/2.14 15 11.43 1.1 1.3 1.5 17.5 19/1.53 7.65 1.3 11.5 120 18 12.95 1.2 1.5 19.5 19/1.78 18 8.90 1.5 1.6 13.5 150 14.27 1.4 21.5 19/2.14 10.70 1.5 15.5 18519/2.52 30 15.98 1.6 1.6 23.5 12.60 1.7 18.0 24037/2.03 34 18.47 1.7 1.7 26.5 14.21 1.7 19.5 30037/2.25 34 20.68 1.8 1.9 1.8 29.0 15.75 21.5 17.64 24.0 40037/2.52 53 23.39 2.0 2.1 1.9 32.5 20.25 27.0 50061/2.25 53 26.67 2.2 2.3 2.0 36.5 22.68 30.0 63061/2.52 53 30.22 2.4 2.5 2.2 41.0 61/2.85 25.65 2.7 33.5 800 53 34.00 2.6 2.3 45.5 61/3.20 28.80 3.1 38.0 C = Packing in coil DRevision =B Packing drum 2010 31 : 00, inMay Revision : 00, May 2010 M-km (Min.) M-km (Max.)0.0715 (Min.) 12.10.0141 2,550 7.410.0135 2,100 4.610.0123 1,700 3.080.0116 1,450 1.830.0102 1,250 0.0093 1.150.0094 1,000 0.7270.0085 1,050 0.5240.0073 900 0.3870.0069 850 0.2680.0057 800 0.1930.0054 700 0.1530.0047 650 0.0046 700 0.124 0.0039 0.09910.0038 700 0.07540.0034 650 0.06010.0034 600 0.04700.0034 600 0.03660.0033 600 0.02830.0032 550 0.02210.0030 550 0.0031 /km AA 11 1627 1636 2148 2161 2982 29 39110 39145 51180 70220 96280 127345 157400 191460 244 297530 345630 397725 453840 535 1,000 617 1,170 741 1,340 854 Cable Standard Standard length weight length kg/km A kg/km m m/drum (Approx.) (Approx.) 11 100/C 3317 50 100/C 500 4317 60 100/C 500 22 56 80 100/C 500 22 71 100 100/C 500 31 94 150 100/C 500 31 100/C 12050 210 100/C 500 15550 320 100/C 500 185 420 75 100/C 500 225 560 100/C 500 120 180 275 770 100/C 500 290 330 1,050 100/C 500 380 375 1,300100/C 500 540 500/D 500 425 1,600 720 500/D 480 2,000 500/D 500 1,000 560 2,600 500/D 500 1,240 635 3,230 500/D 500 1,520 1,900 725 4,100 500/D 500 2,480 830 5,260 500/D 500 3,100 945 6,780 500/D 400 3,950 1,060 8,630 300/D 400 5,150 300/D B 31 B2