Aritech Magnetic Locks Commercial & Technical Training (Version 0800)

Download Report

Transcript Aritech Magnetic Locks Commercial & Technical Training (Version 0800)

Aritech Magnetic Locks
Commercial & Technical
Training
(Version 0800)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
Contents
1. General (2)
2. Applications (3)
3. Products (16)
4. Installation (8)
5. Wiring /
connections (10)
6. Troubleshooting
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
1. General
• Installing an electromagnet is particularly easy.
There is no need to be a specialist installer of locks.
• The magnet attracts the armature plate and holds it
tight. That is the reason why the plate has to be
fitted as close as possible to the magnet.
• A magnet correctly installed, never affects its
surroundings because it is a closed magnetic field.
When used correctly, there is no interference with
nearby installations and no health risks.
• The electromagnetic locks EM are particularly well
treated to resist corrosion. But care must be taken
to protect the electrical parts and connections.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
1. General
• There is NO residual magnetism on the EM magnets!
It means that as soon as the power is switched off,
the lock is released immediately and there is no
residual holding.
• The EM electromagnets do not require special
maintenance. It is important not to clean them with
an abrasive or a solvent.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
2. Application - 1
1800 Newton
• Small magnet designed for light but reliable and
secure locking. Particularly well adapted for locking
glass doors, or medium internal doors of modern
offices
3000 Newton
• Intermediate range of magnets meeting most of the
middle range security needs. It is recommended for
the majority of internal doors as they do not have to
be resistant to heavy attacks.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
2. Application - 2
5300 Newton
• Basic electro-magnet, specially designed to combine
a maximum holding force with low power
consumption. This magnet is used for all high
security access where efficiency and security cannot
be comprised.
The Shearlock
• This is a hybrid magnet mixing a classical electromagnet and an electric lock. The shearlock is the
only solution for fitting a flush magnet on a swinging
door.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
2. Application - 3
Accessories
• The mounting brackets are made from extruded
anodized aluminium. They adapt the magnets for all
kinds of doors.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, not monitored - 1
• FE411
• Vertical
• 1330N
• 12 VDC
• 400 mA
• Stainless steel
• 162 x 32 x 23 mm (w x h
x d)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, not monitored - 2
• FE321
• Standard / surface
• 3000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 48 x 25 mm (w x h
x d)
• FE32Z, FE32L, FE32A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, not monitored - 3
• FE319
• Mortice
• 3000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 229 x 39 x 24 mm (w x h
x d)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, not monitored - 4
• FE370
• Standard
• 6000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 73 x 40 mm (w x
h x d)
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 1
• FE310 / FE312
• Standard / Mortice
• 1800N
• 12/24 VDC
• 380/190 mA
• Anodized Aluminium
• 166 x 39 x 21 mm (w x
h x d)
• Reed
• FE31Z / none
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 2
• FE322
• Mortice
• 3000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 229 x 39 x 24 mm (w x
h x d)
• Reed
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 3
• FE323
• Standard / surface
• 3000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 48 x 25 mm (w x
h x d)
• Relay + LED
• FE32Z, FE32L, FE32A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 4
• FE371
• Standard / surface
• 6000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 73 x 40 mm (w x
h x d)
• Relay + LED
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 5
• FE 372
• Standard / surface
• 6000N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 73 x 40 mm (w x
h x d)
• High secure: 2 relays
+ LED
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Single, monitored - 6
• FE772
• Standard / surface
• 5790N
• 12/24 VDC
• 500/250 mA
• Anodized Aluminium
• 268 x 75 x 40 mm (w x
h x d)
• Dual: Reed + Hall
effect and relay
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Dual, not monitored - 1
• FE425
• Standard / surface
• 2 x 2890N
• 12/24 VDC
• 2 x 500/250 mA
• Anodized Aluminium
• 500 x 42 x 24 mm
• FE480, FE481, FE482,
FE483
• (FE482 is Z/L kit for
inswinging doors)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Dual, not monitored - 2
• FE375
• Standard / surface
• 2 x 6000N
• 12/24 VDC
• 2 x 500/250 mA
• Anodized Aluminium
• 536 x 73 x 40 mm (w x
h x d)
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Dual, monitored - 1
• FE426
• Standard / surface
• 2 x 2890N
• 12/24 VDC
• 2 x 500/250 mA
• Anodized Aluminium
• 500 x 42 x 24 mm
• Hall effect and relay
• FE480, FE481, FE482, FE483
• (FE482 is Z/L kit for
inswinging doors)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Dual, monitored - 2
• FE376
• Standard / surface
• 2 x 6000N
• 12/24 VDC
• 2 x 500/250 mA
• Anodized Aluminium
• 536 x 73 x 40 mm (w x
h x d)
• Relay + LED
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Dual, monitored - 3
• FE777
• Standard / surface
• 2 x 5790N
• 12/24 VDC
• 2 x 500/250 mA
• Anodized Aluminium
• 500 x 75 x 40 mm (w x
h x d)
• Dual: Reed + Hall
effect and relay
• FE37Z, FE37L, FE37A
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
3. Products:
Shearlock
• FE380
• Mortice
• 8000N
• 12 VDC
• 250 mA
• Anodized Aluminium
• 165 x 31 x 21 mm (w x
h x d)
• Relay + LED
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation (see steps on next slide)
• Start first by fitting the armature plate (do not
tighten the screw too much) and install the magnet
next.
• After you fit the plate, power the magnet with a 9 volt
battery. It will stick to the plate and you will have
your two hands free to mark the outlines of the
magnet with a pencil on the frame.
• After checking that the system is working correctly,
slightly unscrew the armature plate and put a drop
of thread locking compound into the thread of the
screw.
• Do a final check on the movement of the plate.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - armature
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4.
Installation
Electromagnet
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - FE380
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - armature
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - L-bracket
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - Z-bracket
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
4. Installation - glass bracket
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
Connecting an electromagnet is simple. Nevertheless,
it can be useful to carefully read the following notes:
• The minimum voltage for the power supply must be
12/24 Volts DC minimum (tolerance of –0% + 20 %).
• This voltage should always be measured on the
magnet connector and not on the connector of the
power supply.
• An electric cable has a loss of voltage directly
proportional to its length and inversely proportional
to its cross-section as explained here after:
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
The basic formula is: Rw = (r x L) / S
Rw :
resistance of the wire
r:
specific resistance determinate by the type of
wire (for copper 0,0175 ohm)
L:
length in meter (attention, there are 2 wires. Do
not forget to multiply by 2!)
S:
cross-section of the wires in mm2
And the ohm law: V = R x I V: voltage (volts)
R:
resistance (ohm)
I:
Current (ampere)
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring - example
3 magnets are installed at 25 meters from the power supply! They
are powered in 12 VDC and each of them has a consumption of
500 Ma. The wire has a section of 0,5 mm2.
• We have then a cable length of 50 m (there are 2 wires) and a
total consumption of 1,5 A (1500 mA)
• A: Calculation of the resistance of the wire:
• R = (0,0175 x 50) / 0,5 = 1,75 ohm
• B: Calculation of the voltage drop:
• V = 1,75 x 1,5 = 2,62 volts
• The magnet must have as a minimum its nominal voltage on the
connector, which in this case 12 VDC.
• As the cable will cause a voltage drop of 2,62 volts, it will be
necessary to adjust the power supply to 14,62 volts minimum.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
- FE370 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
FE312 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
FE322 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
FE323 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
FE371 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
F
FE372 connections
UK
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
5. Wiring
FE380 connections
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
6. Troubleshooting
The armature plate is too tight:
• This is a common error when you install a magnet
for the first time. The installer is concerned when he
sees that the plate is loose and he overtightens the
screw, to crushing the rubber washer and clamping
the whole set together. However, a door has an
angular motion, and it is the flexibility of the
armature plate that compensates for this movement.
The more flexible the plate, the better the system
will function (see: installation of the armature plate).
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa
6. Troubleshooting
The voltage on the magnet connector is too low :
• This is another classic problem of first-time
installation. The electromagnetic locks have to be
powered in 12 VDC or 24 VDC minimum. If the
voltage is lower, the holding force will be also
lowered and the monitoring will not function
properly.
• Attention: The magnets are supplied with a factory
setting to 24VDC. If you power in 12VDC, do not
forget to change the voltage selection
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa