Document 7575813

Download Report

Transcript Document 7575813

Akro Fireguard
Developments in:
- Low Smoke Fire Resistant Floor Coverings
- Low Smoke Fire Resistant Interior Repair Compounds
j
9001 Rosehill Road, Lenexa, KS 66215 USA
Tel: (+1) 913 888 7172 Fax: (+1) 913 888 7372
Website: http://www.akrofire.com
Background
Akro Fireguard
•Wool – Naturally flame retardant and used to meet stricter OEM FST requirements.
Used extensively outside USA
•Conventional Nylon – Brominated Flame retardants – meets FAA standards.
Used extensively in USA
Summary:
•Wool – Good FST Performance – Poor Operational Performance.
Meets OEM FST requirements
•Nylon – Excellent Operational Performance – High smoke and toxic gases.
Up to 5x ware improvement
AkroBak Nylon – The best features of wool and Nylon
j
Low Smoke Fire Resistant Floor Coverings:
AkroBak® Nylon Carpet
Comparative Data: FST Requirements FAA : OEM
Akro Fireguard
FAR 25.853 Requirements
OEM Requirements
(Summary ref, ABD0031 & BSS 7239/8)
Vertical Burn: 12seconds
Vertical Burn: 12seconds
Smoke Density: N/R
Smoke Density: 150 (300) Dm after 4 min
Toxicity:
Toxicity:
N/R
j
Low Smoke Fire Resistant Floor Coverings
CO: 3500 ppm
HCN: 150 ppm
HF: 100 (200) ppm
HCL: 150 (500) ppm
SO2: 100 (200) ppm
NOX: 100 ppm
AkroBak® Nylon Carpet
Vertical Burn : Summary of Results
Akro Fireguard
Length Direction
Specimen
Flame
Application
1
2
3
12
12
12
Average
Flame
Time
Sec.
Burn
Length
Inch
Flaming
Drippings
Flame
Time
Sec.
Burn
Length
Inch.
Flaming
Drippings
1
0
0
2.7
2.7
2.4
0
0
0
0
1
1
2.6
2.7
2.6
0
0
0
0.3
2.6
0.0
0.7
2.6
0.0
Low Smoke Fire Resistant Floor Coverings
j
Width Direction
AkroBak® Nylon Carpet
Comparative Data: Smoke Density
Akro Fireguard
Nylon Carpet Smoke Tests
ASTM E662, 4-min. flaming mode
A smoke density of 470 is the
instrumental measurement limit
500
Smoke Denisty
NYLON
400
AKROBAK NYLON
300
LIMIT
200
100
0
0
1
2
3
4
Time (min)
j
Low Smoke Fire Resistant Floor Coverings
AkroBak® Nylon Carpet
Comparative Data: Toxicity
Akro Fireguard
Toxicity - ASTM E 662 (Flaming Mode)
Maximum Allowable
3500
3500
3000
2500
2000
ppm
1500
1000
500
Requirement
AkroBak
150
100
150
100
100
HCL
0
SO2
15
NOx
30
0
Actual Akrobak results
CO
100
HCN
25
HF
0
Compound
j
Low Smoke Fire Resistant Floor Coverings
AkroBak® Nylon Carpet
‘In service Durability’
Akro Fireguard
Testing performed, summary of results
Static propensity – BSS 7311: Leather/Rubber 0.5kV, Composition : 0.6kV - Requirement < 2.5kV
Dimensional Stability (4’x10’ Sample) – BSS 7310: Length: -0.5%, Width 0% - Requirement < 5%
Vetterman Drum Test (22,000 revolutions): Rating 3.3 (Moderate Change) - Requirement N/A
Hexapod Tumbler – ASTM D-5252, 12,000 cycles: Rating 3 (Moderate Change) - Requirement N/A
Ultimate performance indicator - in service experience:
3x improvement in longevity over traditional FST compliant carpeting
j
Low Smoke Fire Resistant Floor Coverings
AkroBak® Nylon Carpet
CONCLUSION
Akro Fireguard
AkroBak Nylon Carpet
•Superior resistance to soiling and staining.
•Superior durability and maintainability.
•Low weight.
•Total cost of ownership
•Meets the highest FST standards
•Does not contain Bromine compounds and is therefore compliant with current and
Impending legislation.
Visit us at http://www.akrofire.com
j
Low Smoke Fire Resistant Floor Coverings
AkroBak® Nylon Carpet
AF444 SpeedFill
Akro Fireguard
AF444 SpeedFill was developed to provide a universal filling and repair compound that
would meet:
•OSU Heat Release
•Vertical Burn
•Smoke Density
Cure characteristics such that the material can be used effectively during ‘change
around’ operations.
j
Low Smoke Fire Resistant Interior Repair Compounds
AF444 SpeedFill
Akro Fireguard
Basic Properties
•FAR 25.853 OSU Heat Release
Average: 12 Peak: 45
ASTM E662 Smoke Density (flaming mode)
127
Vertical Burn
12 second & 60 second
Compressive Strength
6360 psi / 44MPa
Density
1.16g/cm3 / 72lb/ft3
j
Low Smoke Fire Resistant Interior Repair Compounds
AF444 SpeedFill
Handling
Akro Fireguard
•Mixing:
2 pack system, Part A & B, 2% Part B
•Application:
Trowel / Spatula
•Shaping
After 10 to 20 minutes
•Cure
30 to 40 minutes
Applications
•Sandwich Panel core repair:
(Airbus approved for cargo liner repairs)
•Interior panel repair
j
Low Smoke Fire Resistant Interior Repair Compounds
AF444 SpeedFill