Instrumentation: Interconnect template

Download Report

Transcript Instrumentation: Interconnect template

ELECTRICAL INTERCONNECT DIAGRAM for “New chemistry sensor” IDEAS-4 C-130 project,
08/22/2011 Show all interconnecting cables, circuit protection devices, etc. Template only!
Chemistry
reaction
chamber
7A
Maximum power draw
Power(1): 5.5A/28VDC
Wire specifications (see
www.eol.ucar.edu/instrumentation/aircraft/GV/documentation/approved-wire)
Wire
Power(1)
Power(2)
Power(3)
Power(2): 4A/110VAC
Power(4)
Power(5)
Ethernet
HIMIL heater
2A
Power(3): 0.5A/110VAC Tube wire
Tube heater
RS-232 cable
Ethernet
Controller cable
6A
Controller cable(7)
Pump
Laptop
16-TE-1929(3)
16-TE-1929(3)
16-TE-1929(3)
16-TE-1929(3)
16-TE-1929(3)
E50824
etc.
STP
18-TE-1930(2)STJ
Minco HR66xxRxx.xL36B
etc.
STP-22 CME4-02-STW-2219
RS-232 to C-130 data
system
HIMIL
6A/28VDC
Heater circuit 1
to anti-ice HIMIL
HIMIL copper sample
tube, 4x MINCO
heaters,
4x 28VDC/15W
STT-16
STT-16
STT-16
STT-16
STT-16
Heater circuit 2
to tube heaters
10A
Power(4): 8A/28VDC
6A
Power(5): 4.5A/28VDC
Diagram provided by: Douglas Bogus, [email protected], 303-444-4444
NCAR-ID
STJ
STJ
STJ
STJ
STJ
6753
81173
75859
PLUMBING INTERCONNECT DIAGRAM for “New chemistry sensor” IDEAS-4 C-130 project,
08/22/2011 Template only; show all tubing, etc.
Sampl
e tube
HIMIL
anti-iced
inlet.
One
forward
facing
¼”OD SS
tube.
Chemistry
reaction
chamber
Pump tube
Pump
Laptop
Heater circuit 1
to anti-ice HIMIL
Exhaust tube to
floor dump
Tube specifications (see
www.eol.ucar.edu/instrumentation/aircraft/GV/documentation/approved-wire)
Tube
Sample tube
Pump tube
Exhaust tube
Manufacturer
Cambridge-Lee
Saint-Gobain
Saint-Gobain
Material
¼”Copper
3/8”Comp
3/8”Comp
Part
¼”OD, 0.190”ID
SYNFLEX 1300-06603
SYNFLEX 1300-06603
NCAR-ID
677F-6C
677F-6C
Heater circuit 2
to tube heaters
Diagram provided by: Douglas Bogus, [email protected], 303-444-4444.