Meditech Multiparameter Monitor
12 inch high brightness colorful TFT Display
Analysis of real time ST segment and arrhythmia
Powerful data review for graphic, tabular trends and alarms review
Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR Maxi 96 hour graphic
and tabular trend with data storage
Big font, oxyCRG, Full-lead ECG interface to meet different requirement;
LAN or wireless network connection as central monitoring system;
Digital SPO2 enables effective examination in case of active patient, low infusion and
interference from electric knife
Protection against high-frequency electro tome and defibrillation effects
Optional configuration:
IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG
ECG
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; V
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: ± 1bpm or ± 1%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage in isolation
against electrosurgical and defibrillation
S-T detection: YES, Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
Pulse Oximetry
SPO2 Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%;
1% to 69% range: ±5%;
Method: Dual wavelength LED
NIBP (Non-invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 40 to 240 mmHg
Neonate: 10 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement
Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult: 300mmHg
Pediatric: 240 mmHg;
Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range: 30 to 250 bpm
Accuracy: ±2 bpm or ±3%, whichever is greater
Respiration Rate
Method Impedance between R-F(RA-LL)
Differential Input Impedance
>2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range:
0 – 2.5 KΩ
Bandwidth
0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped
0 ~ 150 rpm
Resolution 1 rpm
Accuracy
2 rpm
Apean Alarm 10 ~ 40 S
TEMP
Measuring and Alarm Range 0 ~ 50 C
Resolution
0.1 C
Accuracy
0.1 C
Actualization interval
about 1 Sec.
Average Time Constant < 10 Sec.
Printer (optional)
Type: Thermal printer
Paper Speed: 6.25, 12.5, 25 mm/sec
Power Requirements
Voltage: 110-240 V AC; 50 Hz
Power Consumption: 8 Watts, typical
Battery: 1 sealed lithium battery
Battery Life: 8 hours, typical
Recharge Time: 4 hours, typical
Interface & Display
Keys: 9; membrane activated
Rotary Knob: Push and rotate; 24 steps/turn
Screen: 15 inch active color TFT
Resolution: 800 x 600 pixels
Wave forms: 8 maximum
Sweep Speed: 6.25, 12.5, 25 mm/s
Languages: English