MD9015 Multiparameter-Patient-Monitor/Multiparameter-Patient-Monitor-15-inch

Download Report

Transcript MD9015 Multiparameter-Patient-Monitor/Multiparameter-Patient-Monitor-15-inch

Meditech Multiparameter Monitor

        15 inch high brightness colorful TFT Display Analysis of real time ST segment and arrhythmia Powerful data review for graphic, tabular trends and alarms review Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR Maxi 96 hour graphic and tabular trend with data storage Big font, oxyCRG, Full-lead ECG interface to meet different requirement; LAN or wireless network connection as central monitoring system; Digital SPO2 enables effective examination in case of active patient, low infusion and interference from electric knife Protection against high-frequency electro tome and defibrillation effects

Optional configuration:

IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG

ECG

Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C Lead selection: I; II; III; avR; avL; avF; V Sweep speed: 12.5mm/s, 25mm/s, 50mm/s Accuracy: ± 1bpm or ± 1%, whichever is greater Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation S-T detection: YES, Arrhythmia analysis: YES Alarm: YES, audible and visual alarm, alarm events recallable

Pulse Oximetry

SPO2 Range: 1% to 99% Resolution: 1% Accuracy: 70% to 99% range: ±2%; 1% to 69% range: ±5%; Method: Dual wavelength LED

NIBP (Non-invasive Blood Pressure)

Technique: Oscillometric during inflation Range: Adult/Pediatric: 40 to 240 mmHg Neonate: 10 to 150 mmHg Measurement Cycle: < 40 sec. typical Automatic Measurement Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr STAT Mode: 5 minutes of continuous readings Max. Allowable Cuff Pressure: Adult: 300mmHg Pediatric: 240 mmHg; Neonate: 150 mmHg Resolution: 1 mmHg Transducer Accuracy: ±2 mmHg or ±2% of reading,

Heart (Pulse) Rate

Range: 30 to 250 bpm Accuracy: ±2 bpm or ±3%, whichever is greater

Respiration Rate

Method Impedance between R-F(RA-LL) Differential Input Impedance >2.5 M Ω Measuring Impedance Range: 0.3~5.0

Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult 0 ~ 120 rpm Neo/Ped 0 ~ 150 rpm Resolution 1 rpm Accuracy  2 rpm Apean Alarm 10 ~ 40 S

TEMP

Measuring and Alarm Range 0 ~ 50 C Resolution 0.1 C Accuracy 0.1 C Actualization interval about 1 Sec. Average Time Constant < 10 Sec.

Printer (optional)

Type: Thermal printer Paper Speed: 6.25, 12.5, 25 mm/sec Power Requirements Voltage: 110-240 V AC; 50 Hz Power Consumption: 8 Watts, typical Battery: 1 sealed lithium battery Battery Life: 8 hours, typical Recharge Time: 4 hours, typical

Interface & Display

Keys: 9; membrane activated Rotary Knob: Push and rotate; 24 steps/turn Screen: 15 inch active color TFT Resolution: 800 x 600 pixels Wave forms: 8 maximum Sweep Speed: 6.25, 12.5, 25 mm/s Languages: English