HYDRAULISCHE BALANS

Download Report

Transcript HYDRAULISCHE BALANS

HYDRAULISCHE BALANS Roel Vandenbulcke / Fred van Schaik 5 november 2014 Performance through transparency
HYSOPT - Hydronic System Optimisation
MILLIONS FACTS & FIGURES
OPGERICHT IN 2013
ALS SPINN OFF UNIVERSITEIT ANTWERPEN
3,5 3 2,5 2 1,5 1 SOFTWARE ONTWIKKELING &
COMPETENCE CENTER IN BELGIË
0,5 0 2013 START INTERNATIONALE MARKETING
& SALES IN JULI 2014
2014 INVESTMENT 3x
6x
2013
2015 RENEVUE 12x
2014
2016 18x
2015
Performance through transparency
2016
HYSOPT - Hydronic System Optimisation
PRODUCTEN & DIENSTEN
SOFTWARE
design environment, calculation tool and
simulation tool
CONSULTANCY
Calculate, simulate and optimize projects
according to KPIs
ACADEMY
Software training, seminars and workshops
INDUSTRY
Competence center for R&D projects, product
implementation, marketing cooperation and OEM
Performance through transparency
HYDRAULISCHE BALANS
EMISSIE
HVAC = warmte/koude distributie
DISTRIBUTIE
PRODUCTIE
Warmtestromen nauwkeurig
regelen !
Te weinig warmte
Te veel warmte
Te koud L
Te warm, energieverlies L L
Performance through transparency
HYDRAULISCHE BALANS
De regelkring
Nauwkeurigheid, snelheid, stabiliteit!
Hydraulische aspecten:
error SP + regelaar actuator proces PV •  Lineariteit
•  Hydraulische balans
•  Klepautoriteit
-­‐ sensor Performance through transparency
HYDRAULISCHE BALANS
De regelkring
Nauwkeurigheid, snelheid, stabiliteit!
sensor SP + -­‐ error regelaar PV actuator proces error SP + Hydraulische aspecten:
regelaar actuator -­‐ PV • 
• 
• 
• 
sensor Performance through transparency
Lineariteit
Hydraulische balans
Klepautoriteit
Interactiviteit
8
HYDRAULISCHE BALANS
7
Voorbeeld:
6
5
•  Ventiloconvectoren 3800W, 75/65/20°C
4
•  Ontwerpdebiet 0,33 m³/h
3
•  Geen inregelafsluiters
2
1
Performance through transparency
8
HYDRAULISCHE BALANS
0,33 m³/h
7
0,66 m³/h
Voorbeeld:
6
0,99 m³/h
5
1.  Berekenen ontwerpdebieten (P = m * c * ∆T)
1,32 m³/h
4
1,65 m³/h
3
1,98 m³/h
2
2,32 m³/h
1
2,65 m³/h
Performance through transparency
8
HYDRAULISCHE BALANS
DN15
7
DN20
Voorbeeld:
6
DN25
5
1.  Berekenen ontwerpdebieten (P = m * c * ∆T)
2.  Selectie leidingdiameters volgens ∆pspec
DN32
4
DN32
3
DN32
2
DN32
1
DN32
Performance through transparency
∆pHX
∆p8
HYDRAULISCHE BALANS
∆p7
Voorbeeld:
∆p6
1.  Berekenen ontwerpdebieten (P = m * c * ∆T)
2.  Selectie leidingdiameters volgens ∆pspec
3.  Berekenen ontwerpdrukval
∆p5
∆p4
∆p3
∆p2
8
7
6
5
4
3
2
1
∆p1
Performance through transparency
∆pHX
∆p8
HYDRAULISCHE BALANS
∆p7
Voorbeeld:
∆p6
1.  Berekenen ontwerpdebieten (P = m * c * ∆T)
2.  Selectie leidingdiameters volgens ∆pspec
3.  Berekenen ontwerpdrukval
4.  Berekenen opvoerhoogte van de pomp
∆p5
∆p4
∆p3
∆p2
8
7
6
5
4
3
2
1
∆p1
∆ppomp = ∑ ∆pi + ∆pHX
Performance through transparency
HYDRAULISCHE BALANS
Analyse hydraulische balans
•  Te weinig debiet in bovenste appartementen!
•  Te veel debiet in onderste appartementen!
8
-76 %
7
-52 %
6
-15 %
5
+12 %
4
+30 %
3
+61 %
2
+106 %
1
+173 %
+239 %
Performance through transparency
HYDRAULISCHE BALANS
Regelstrategie
8
-76 %
7
-52 %
6
-15 %
5
+12 %
4
+30 %
3
+61 %
2
+106 %
1
+173 %
•  Weersafhankelijke kringtemperatuur
•  Compensatie stooklijn volgens referentielokaal
Performance through transparency
HYDRAULISCHE BALANS
Gedrag kamertemperatuur
8
5
1
20°C
L Te koud!
„OK“
L Te warm!
8
-76 %
7
-52 %
6
-15 %
5
+12 %
4
+30 %
3
+61 %
2
+106 %
1
+173 %
Gas: 6130 kWh, 89,9%
Pomp: 5,0 kWh
Performance through transparency
HYDRAULISCHE BALANS
Gedrag kamertemperatuur
8
5
1
20°C
L Te koud!
„OK“
L Te warm!
8
-76 %
7
-52 %
6
-15 %
5
+12 %
4
+30 %
3
+61 %
2
+106 %
1
+173 %
Gas: 6130 kWh, 89,9%
Pomp: 5,0 kWh
Compensatie door stooklijnverhoging?
Performance through transparency
HYDRAULISCHE BALANS
Compensatie door stooklijnverhoging (nieuw ref. Ruimte)
8
5
1
20°C
L Nog steeds
te koud!
L Veel te warm!
L Veel te warm!
8
-76 %
7
-52 %
6
-15 %
5
+12 %
4
+30 %
3
+61 %
2
+106 %
1
+173 %
Gas: 6961 kWh, 88,5%
Pomp: 4,9 kWh
+ 14 % !
Performance through transparency
8
HYDRAULISCHE BALANS
7
Hydraulische balanceren met inregelafsluiters
(IRA‘s)
KV –waardes IRA‘s:
6
5
4
1 2 3 4 5 6 7 8 1,43 1,56 1,70 1,83 1,92 2,20 3,13 ∞ 3
2
1
Performance through transparency
8
HYDRAULISCHE BALANS
7
Hydraulische balanceren met inregelafsluiters
(IRA‘s)
1..8
20°C
6
5
4
J
3
Goed
thermisch
comfort !
2
1
Gas: 5636 kWh, 91,3%
Pomp: 4,8 kWh
- 19 % !
Performance through transparency
HYDRAULISCHE BALANS
Energieverbruik van de condensatieketel
Gas (kWh) 7500 88,5 %
7000 6500 A = geen IRA‘s, stooklijn
89,9 %
6000 91,3 %
B= geen IRA‘s , verhoogde stooklijn
C= perfecte balans met IRA‘s
5500 5000 4500 A B C Performance through transparency
HYDRAULISCHE BALANS
Thermisch comfort
te warm
te koud
RTL (Ks) 50000 RTE (Ks) 45000 A = geen IRA‘s, stooklijn
40000 35000 B= geen IRA‘s , verhoogde stooklijn
30000 25000 C= perfecte balans met IRA‘s
20000 15000 10000 5000 0 A B C Performance through transparency
HYDRAULISCHE BALANS
Pompenergie
Lager debiet = minder pompenergie Pompenergie (kWh) 5,05 5 A = geen IRA‘s, stooklijn
4,95 4,9 B= geen IRA‘s , verhoogde stooklijn
4,85 C= perfecte balans met IRA‘s
4,8 4,75 4,7 A B C Performance through transparency
HYDRAULISCHE BALANS
CONCLUSIES
1.  Hydraulisch balanceren bespaart energie
2.  Het ketelrendement stijgt door een lagere
retourtemperatuur
3.  Het thermisch comfort wordt drastisch verbeterd, minder te
koud, minder te warm
4.  Het lagere debiet resulteert in een verlaagde pompenergie
5.  Balanceren = PROBLEMEN VOORKOMEN !!!
Performance through transparency
HYSOPT SOFTWARE
Performance through transparency
Dank u!
Performance through transparency