Fort Leonard Wood Energy Program A Briefing For: Society of American Military Engineers–SAME and Honorable Katherine Hammack Assistant Secretary of the Army for Installations, Energy,
Download ReportTranscript Fort Leonard Wood Energy Program A Briefing For: Society of American Military Engineers–SAME and Honorable Katherine Hammack Assistant Secretary of the Army for Installations, Energy,
Fort Leonard Wood Energy Program A Briefing For: Society of American Military Engineers–SAME and Honorable Katherine Hammack Assistant Secretary of the Army for Installations, Energy, & Environment Presented By: Mr. Bobby N. Rakes, Jr. Director, Directorate of Public Works Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 1 10 March 2015 Agenda Relevance Access Transmission Reliability Consumption Intensity Reporting Efficiency Renewables Metering Key Takeaways Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 2 10 March 2015 Energy Relevance Complies with Governing References Energy Policy Act (EPACT) of 2005 Energy Independence Security Act (EISA) of 2007 Executive Order 13693, Planning for Federal Sustainability in the Next Decade, March 2015; this Order revokes previous Executive Orders 13423 and 13514 and conforms several others used as prior guidance for Federal Energy Managers DODI 4170.11, Installation Energy Management DODI 4140.25, DOD Management Policy for Energy Commodities & Related Services AR 420-1, Part V, Energy & Utilities Management Implements Goals & Objectives - Army Energy Security Implementation Strategy - IMCOM Campaign Plan & Garrison Commander’s Campaign Plan - TRADOC Commander’s Directive Supports the Mission Reduced Utility Costs = Available Funds Fort Leonard Wood Purchases >$33.5M on Energy (>$25.1M on Electricity) Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 3 10 March 2015 Access to Energy Purpose: Focused on developing and/or procuring cost competitive, secure, and renewable sources Accomplishments to Date: • • • • • Granted MISO/SPP Market Participant Status Sub 2 upgrade and Sub 6 construction complete Upgraded transmission ring Added four feeders from Sub 6 (now total of seven) EITF study of renewable generation completed Next Steps: • Participation in the electricity open market • Must include sufficient power for reimbursable tenants; adds 18% • Requesting renewable energy pricing in the Request for Proposals (RFP) Committed to Sho-Me Power through Dec. 31, 2015 Cost of Electricity is at 8¢ / kwh as of Apr 2014 Each 1/2¢ increase is a cost of approximately $1,200,000/yr. Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 4 10 March 2015 Electricity Transmission System High Voltage Sub 4 (161 KV) Substation 1 Substation Capacities Upgraded High Voltage Distribution Lines Total System: 154 MW (at 95% power factor) Substation 5 Sub 1: 44 MW Sub 2: 40 MW Sub 3: 44 MW Sub 4: high voltage Sub 5: 15 MW Sub 6: 20 MW* 163 MW High Voltage Distribution Ring (69 KV) Substation 2 Substation 6 163MW @ 95% = 154 MW Sub 6 brought add’l capacity to the system but also added redundancy and reliability with the addition of 4 feeder lines *expandable to 40 MW Peak Usage: Recent Peak: Substation 3 55 MW Aug ‘11 50 MW Aug ’14 Possible site for Substation 7 Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 5 10 March 2015 Reliability Utility Privatization Purchases Electricity: Laclede Electric Cooperative Consumption (MBtu) - privatized in 2003 - contract renewal in 2053 - peak to capacity ratio: 55/154 MW ~ 35% Natural Gas: Omega Pipeline Company, LLC Electric Propane - ‘privatized’ in 1995 by contract modification - contract renewal in 2015 - peak to capacity ratio: 6.3/14.0 MCF ~ 45.5% Nat Gas Fuel Oil Cost (Total $) Water / Wastewater: Government-Owned, Contractor-Operated - Currently under study for privatization - Target date for proposals FY17 Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 6 Electric Nat Gas Propane Fuel Oil 10 March 2015 Reduce Consumption Energy Policy: Build a culture of energy responsibility. • Assigns Energy Conservation Coordinators and Building Energy Monitors • Incorporates energy conservation practices and minimizes wasted energy • Balances a commander’s ability to execute the mission with an awareness for energy cost • Executes at personal and unit/operational levels MBtu Energy Consumption 1,800,000 1,600,000 1,400,000 1,200,000 1,000,000 800,000 600,000 400,000 200,000 - Examples of What Can Be Done Personal Level • Awareness / Action • Program Thermostats • Turn off lights • Unblock vents • Close doors / windows • Share rides / Bike / Walk Energy Cost per Year $30,000,000 Unit / Operational Level $25,000,000 • Lead by example $20,000,000 • Planning & Scheduling • Increase Teleconferencing $15,000,000 • Mock Utility Billings $10,000,000 • Use Checklists regularly $5,000,000 • Report deficient equipment; $maintain good repair Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 7 Electrical Mbtu Thermal Mbtu Total Energy Mbtu Electrical $ Thermal $ Total Energy $ 10 March 2015 Reduce Consumption Examples of Actions Completed: • • Initiate night/weekend setback programs Awareness through media, i.e. newspaper, email, marquee, etc. On-Going: • • • HVAC upgrades & controls Lighting retrofits; conversion to LED MILCON includes many conservation measures LED parking lot lighting (notice older HPS lights in back) Planned: • • Operational changes at central plants, i.e. lower water temperature and pressure Hire REM to audit facilities, identify deficiencies, and develop projects UEPH construction – LEED Gold Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 8 10 March 2015 Energy Intensity Energy Goal Tracking ENERGY INTENSITY Consumption Per Square Foot FY Energy Intensity 160.0 Goal Line Baseline 3%/yr EPACT ‘05 140.0 120.0 Mbtu/Ksf 100.0 80.0 60.0 40.0 20.0 0.0 2003 Rev. 2004 2005 2006 2007 Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 2008 2009 9 2010 2011 2012 2013 2014 2015 10 March 2015 FY14 Fort Leonard Wood Energy Reporting Mandate Congressional / OMB Goal Reduction in Energy Intensity: EISAReduce 3% per year to total by 30% by 2015 (2003 baseline) Use of Renewable Energy: EPAct 2005-At least 3% of total electricity consumption (FY07-09); 5% (FY1012); 7.5% (FY13 +) Reduction in Potable Water Intensity: EO 13514 - Reduce consumption by 2% annually for 26% total by FY 2020 (2007 baseline ) FLW FY14 Score FY14 FLW Trend Performance Issues/Actions Score: Red • -13.3% vs goal of -27% • Influenced by greater demands within facilities, real property reporting of new facilities, harsher weather • Project development position currently vacant • Simulated training increases EUI • New Energy Policy to go into effect in FY15 • UESC and REM program participation planned Score: Red • 0.0% vs 7.5% goal ; renewable production components are not metered • projected to meet future goals through purchases • Current supplier reports 16% renewables system-wide • Office of Energy Initiatives (OEI, formerly EITF) and Pacific Northwest National Laboratory have both concluded renewable energy production is not economically feasible at Fort Leonard Wood • Installing small renewable components, i.e. solar water heating, ground-source heat pumps • 1.2% increase vs -14% goal •20.5% reduction in reported water production as compared to the previous year. • Water is measured as raw production (or purchases) and does not offer a means to account for a growing installation. • The installation produces its own potable water from both surface and ground water sources. Score: Red Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 10 10 March 2015 10 Increase Energy Efficiency Purpose: Intent is to improve efficiency of new and existing facilities and equipment. Savings will occur regardless of personal behaviors. Examples of Accomplishments to Date: • • • • • • • Energy Savings Performance Contracting (ESPC) Training Barracks Upgrade Program (TBUP) Energy projects – i.e. street lights & exit signs to LED Automated building energy controls, with automated setbacks Master Planning to reduce energy and fuel costs (Downtown ADP, “walkable” etc.) Repair by replacement – inefficient energy consuming equipment Incorporate feasible, cost-effective Net Zero practices into new construction and into existing real property; all new construction minimum LEED silver Next Steps: • Implement sustainability planning • Maximize metering efforts to utilize data End-State: High-Performance/Sustainable Facilities Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 11 10 March 2015 Energy Efficiencies Examples of Accomplishments to Date: • LEED Certified projects: 10 Gold, 19 Silver • Closing Dining Facilities and temporary facilities • Facility Reduction Program (FRP) • Repair of failed infrastructure & equipment o High-temp and chilled water line replacement o Boiler and chiller replacements • Automatic Computer Shutdown (NEC) • Alternative Fueled Vehicles (LRC) These 29 projects constitute 90 new facilities: 65 Gold 25 Silver Prime Power School – FLW’s 1st LEED Gold Next Steps: • Develop and submit QUTM and ECIP projects o Fill Energy Engineer vacancy o Hire REM assistance • Identify and program more energy & water conservation projects Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 12 10 March 2015 Renewable Energy Purpose: Increase use of renewable or alternative energy sources Examples of Accomplishments to Date: • • • • • Ground Source Heat Pump systems in new construction (three systems to date) Solar water heating systems incorporated in design Solar traffic lights, street lights, and pedestrian crossing signs Solar wall project in 4th MEB maintenance facility EITF study concluded Next Steps: • Watch for new technology and changes in economics to alter the feasibility of incorporating alternative and renewable energy • Include a line item for renewable electricity purchases in new contract Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 13 10 March 2015 Increase Renewable Energy SOLAR BIOMASS WIND Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] GEOTHERMAL 14 10 March 2015 Metering Purpose - Improve awareness and reduce energy waste by metering and comparing usage Identify and generate energy projects from analysis of building meter data Report data to MDMS – Huntsville Status Electricity Metering (246 adv electric meters installed) Natural Gas Metering (149 adv gas meters installed) Water Metering ( 0 adv water meters installed; ~70 others) Time Line Assessment (As of 24 JAN 2015) - Improve awareness and change energy wasting behaviors by using metered energy use data to foster competition between units -Wireless meter data not allowed direct feed into the local area network - Utility metering for facilities over 29K SF - Net Zero & Energy Security Plan signed JUL ‘12 US Army Corps of Engineers Huntsville Engineering & Support Center is Army Metering Program Lead - JUN ‘12 - FLW began receiving advance meter data - JUL ‘12 - OPORD 12-106 tasked NEC to support Meter Data Management System (MDMS) -JUL ‘14 - SEP ‘15 - Implement guidance - SEP ‘16 - Meters connected & reporting to MDMS - FLW is pilot installation for USACE-ERDC-CERL water consumption modeling (On-going) Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 15 10 March 2015 Key Takeaways • MSCoE/FLW command plan for Net Zero and Energy Security is active and incorporates: - Installation Strategic Sustainability Plan (ISSP) - Garrison Commander’s Campaign Plan (GCCP) • Unregulated electricity supply has driven rising costs; seeking a market solution • FLW Command Energy Policy has been issued to further articulate energy management practices that will help us reach our goals. • New construction, maintenance, replacement and retrofit projects consider energy efficiencies and are making a difference. • Information campaign has ramped up (newspaper, website, computer pop-ups & shut-downs, etc.) to increase awareness. • Energy Security is an integral component of mission readiness and unit preparedness – it is an operational imperative. Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 16 10 March 2015 END OF BRIEF INSTALLATION MANAGEMENT COMMAND “Sustain, Support and Defend ” Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 17 10 March 2015 Acronyms and Abbreviations $M millions of dollars 4TH MEB 4th Maneuver Enhancement Brigade ADP Adaptive Devlopment Plan ECIP Energy Conservation Investment Program EISA EITF EO EPACT ‘05 ESPC EUI FLW FRP FY HPS HVAC IMCOM KSF KV KWH LED LEED LRC Energy Indpendency and Security Act - 2007 Energy Initiatives Task Force, now known as OEI Executive Order Energy Policy Act - 2005 Energy Savings Performance Contract Energy Usage Intensity; interchangeable with Energy Intensity Fort Leonard Wood Facilities Reduction Program fiscal year high pressure sodium heating, ventilation and air conditioning Installation Management Command thousands of square feet kilovolts kilowatt-hours lighted electronic diode Leadership in Energy and Environmental Design Logistics Readiness Center Mr. Allen Simpson/IMLD-PW-O/573-596-0956/[email protected] 3 13 11 12 10 4, 10, 13 10 3, 9, 10 11 3, 10 12, 15, 16 12 10 7 7 3 9, 15 5 4 7, 11 7, 11, 12 12 MBTU MCF millions of british thermal units thousands of cubic feet MDMS Meter Data Management System Military Construction; an Army construction MILCON program Midwest Independent (Transmission) Service Operator MW megawatts NEC Network Enterprise Center OEI Office of Energy Initiatives OMB Office of Management and Budget OPORD Operations Order QUTM Facilities Utilities Management REM Resource Efficiency Manager RFP request for proposal SAME Society of American Military Engineers SouthwestPower Pool (Transmission Service SPP Operator) TBUP Training Barracks Upgrade Program TRADOC Training and Doctrine Command UEPH unaccompanied enlisted personnel housing MISO UESC Utility Energy Service Contract USACE- United States Army Corps of EngineersERDC- Engineering Research Development Center-Corps CERL of Engineers Research Laboratory 18 6, 7, 9 6 15 7 4 5 12, 15 10 15 12 7, 10, 12 4 1 4 11 3 7 10 15 10 March 2015