AGILE: Axially Graded Index Lens fabrication proposal update Week 5 Mentor: Tom Carver Flexible Clean Room, Nano Building Nina Vaidya.
Download ReportTranscript AGILE: Axially Graded Index Lens fabrication proposal update Week 5 Mentor: Tom Carver Flexible Clean Room, Nano Building Nina Vaidya.
AGILE: Axially Graded Index Lens fabrication proposal update Week 5 Mentor: Tom Carver Flexible Clean Room, Nano Building Nina Vaidya UV adhesives of different refractive indices • • • • • NOA138 (1.38) NOA84 (1.46) NOA74 (1.52) NOA63 (1.56) These UV curable adhesives would be used to fill the AGILEs • We already have PDMS 1.4, polyester resin 1.48, epoxy 1.55 • So we can has as many as 9 layers including ice and high index glass 24 x 22mm Monocrystalline Solar Cell • http://www.solarbotics.com/products/scc24 22/ • As a visible light detector for AGILE setup Spectral Transmission Measurements • Spectrophotometer measurements for different film samples to characterize the optical adhesives and the polymers in the Fejer lab (nano 011) • Optical adhesives will be put between two glass slabs with a spacer to make thin films and then this can be used a specimen for the transmission measurements for the polymers that are not characterized Norland products transmission data: https://www.norlandprod.com/adhesives/NOA%20 63.html Testing the optical adhesives of different RI • All except NO138 (RI of 1.38) behave well and are ready for characterization • The NO 84 does how a lot of shrinking which is only a problem in this closed test structure and not in agile • NO 63 and NO74 behave well NOA138 • • • Aliphatic Urethane Acrylate* * 5-20% and Acrylate Monomer * 40%-85% The layer becomes cloudy and yellowish after UV cure, this layer is thick of about 1mm. On closer inspection, the adhesive exhibits oxygen inhibition when used as a coating. To overcome this the adhesive must be cured under an inert atmosphere, such as nitrogen. Transmission Spectrum of NOA138 Filling the first arrays Next steps • First Al array is being filled (flexible clean room is going to be cleaned so it’s a real clean room this week hence the fabrication schedule is push back by almost a week). In this time I am working on characterizing the adhesive films in Spectrophotometer • The back to back structure is being make by Tim Brand in the Crystal shop • The solar detector is tested and will be used in the housing (like in CAD drawing) to test the AGILEs once they are make • Thorlabs red HeNe laser will be used to test the structures (http://www.thorlabs.us/thorProduct.cfm?partNumber=HRP005S)