Config Multi PDN Aux in eHRPD

Download Report

Transcript Config Multi PDN Aux in eHRPD

Multi-PDN and Multi-Aux
Configuration in eHRPD
PROPRIETARY AND CONFIDENTIAL
Agenda
Config Nodal
Config Node
Message Flow and pcap
2
PROPRIETARY AND CONFIDENTIAL
Introduction
PDN connections setup: Main service connection(Main A10) is
responsible for creating the default PDN connection. aux SoType =
59 is responsible for creating additional PDN connections.
If you configure an “Aux SoType = 59” on Landslide GUI, it’s not a
real Aux connection, it just represents an addtionational PDN
connection. Its corresponding APN indicates which PDN it
connects to.
If you configure an “Aux SoType = 67” on Landslide GUI, it’s a real
Aux Connection. Its corresponding APN indicates which PDN this
Aux is related with.
If configuring total N PDN connections including main service
connection and M real auxiliary service connection, you should set
the aux number to N-1+M.
In this test case, I take 2 PDN, and 3 real auxiliary for example.
3
PROPRIETARY AND CONFIDENTIAL
Presupposition
In successor pages, we use main for short of main service
connection, Aux for short of auxiliary service connection.
I just show the difference between Multi-PDN and Multi-Aux with
normal eHRPD case. Other parts are configured the same with
normal eHRPD case.
4
PROPRIETARY AND CONFIDENTIAL
Configuration in Nodal
PROPRIETARY AND CONFIDENTIAL
Nodal Test Configuration
6
PROPRIETARY AND CONFIDENTIAL
Nodal Network Device
7
PROPRIETARY AND CONFIDENTIAL
Nodal Network Device - Cont
8
The number of LMA Node is the same of number of PDN.
PROPRIETARY AND CONFIDENTIAL
Nodal RP-PPP
9
PROPRIETARY AND CONFIDENTIAL
Nodal RP-RP-PDN1
• We should assign N
PDN on the first N
connections.
• The Item in
“service instance
APN Assignments”
is associated with
that in “Service
Instance Setting”.
That is:
• Main -> P0
• Aux-1 -> P1
• Aux-2 -> P2
• Aux-3 -> P3
• Aux-4 -> P4
10
PROPRIETARY AND CONFIDENTIAL
Nodal RP-RP-PDN2
11
PROPRIETARY AND CONFIDENTIAL
Nodal RP-RP-Aux1
12
PROPRIETARY AND CONFIDENTIAL
Nodal RP-RP-Aux2
13
PROPRIETARY AND CONFIDENTIAL
Nodal RP-RP-Aux3
14
PROPRIETARY AND CONFIDENTIAL
Configuration in Node
PROPRIETARY AND CONFIDENTIAL
Node Emulator Configuration
16
PROPRIETARY AND CONFIDENTIAL
Node Network Devices
17
PROPRIETARY AND CONFIDENTIAL
Node Network Devices - Cont
18
PROPRIETARY AND CONFIDENTIAL
Node RP-A11
19
PROPRIETARY AND CONFIDENTIAL
Message Flow for PDN Connection
Please refer to section 5.5.4.1.1 of X.S0057-v3 for details.
20
PROPRIETARY AND CONFIDENTIAL
Each color block represents a connection configured in GUI.
21
PROPRIETARY AND CONFIDENTIAL