Transcript synergy-2

Slide 1



Unlimited backup Power for Optical & HFC networks Without Batteries
SYNERGY-2 – Demo backup power from Area A to Area B

50V

60V

55V

1
Power +
Signal

Area A

40V

Power + Signal

60V

1
From Optical
node

1

3

2

40V
3
P.S

60V
4

Optical Node
Or Trunk amplifier

4

P.S
.S

45V

Area B

To remote /
amplifier /
Node

2

1
2
3
4

Optical Node

60V

AC 2 input.
AC 2 input
Backup IN.OUT (AC+RF to remote Node/ amp)
Local output to local Optical Node.(AC+RF)


Slide 2

SAFECOM & HTC Smart Grid Patented technology providing complete set
of unlimited backup Power for CATV networks & Without Batteries

US PATENT 8,415,822
US PATENT 5,747,888

2


Slide 3

Hulda transformers Company Profile:
 Established in 1975 and is owned by Kibbutz Hulda.
 A part of (KIA) the Kibbutz Industries Association represented over 300
factories & Companies owned by the kibbutz association in Israel
 It total KIA has 35,000 employees & over 8 billons US$ sales/year.

3


Slide 4

Hulda transformers Company
Main Markets :
 Military & Aviation transformers.
 Medical equipment manufacture.
 Cable TV industry.
Safety standard :
CE, BABT, IEC, VDE & UL
Quality Assurance Management System :
ISO 9001:2008 certified.

4


Slide 5

Kibbutz Industries
Association (KIA)

Kibbutz
Organization

Kibbutz
Hulda

Mr David Zilberberg
Privet company
Hulda transformers Company

CATV
Patented Powering
5

CATV
Upstream noise
blocker (UNB)


Slide 6

Safecom Smart Powering Grid Patented technology, providing a complete
set of unlimited backup Power for CATV networks & Without Batteries
Safecom's proven patented SYNERGY-2 , DPSV4, Power Booster & Dual Tformer P.S turns CATV Optical & HTC networks into a super power synergy
platform that provide most reliable and economic powering system for
unlimited backup time.

Power Booster 4G
SYNERGY-2

6

DPS v5

Dual T-former 2X 15A
60,66,72,87 V + DOCSIS
Monitoring


Slide 7

The Backup Power concept.

Based on the strategic placing of
intelligent power management devices
throughout the network, in the event of
a power outage the SYNERGY-2 & DPS4
draws power from the distant available
source over existing coax or power
cables.
Utilizing breakthrough direct
AC/AC On-Line stabilize technology
safecom's SYNERGY-2 and Power Booster
ensures an optimal voltage level – even
over long distances.

Unlimited backup Power for CATV networks & Without Batteries (60V & 90 V standard )


7


Slide 8

 RF PASS 5-1000 MHZ

US PATENT 5747888 EP 0708559

Local

Remote

Based on the strategic placing of intelligent power
management devices throughout the network, in the
event of a power outage the DPSv5 draws power from
the distance available source over existing coax or
power cables.
Safecom's proven smart grid technologies greatly
improve network powering reliability while creating
significant savings in both capital and operational
expenses.
To remote / Node
/ Amplifier

Power +
Signal

 Monitoring
Port: voltage,
Current, status

Power

Booster
Port

AC 2

Optical
Node/Trunk
amp

3

4

P.S

1

2

1 AC 1 input.
2 AC 2 input
3 Backup IN.OUT (AC+RF to remote Node/ amp)

4 Local output to local Optical Node. (AC+RF)


8

Unlimited backup Power for Optical & HFC networks Without Batteries

AC 1


Slide 9

US PATENT 8,415,822
Utilizing patented breakthrough direct on-line zero crossing AC/AC
stabilize technology safecom's ensures an optimal voltage level to
Optical Nodes & Line Amplifiers even the source of power from over
long distances.
Passive , Standalone element , power booster solves the power
distribution problem in a CATV network caused by high-resistance and
low energy efficient coax & electricity cables.

US PATENT
8,415,822

v

v

t

t

Vin 30-87Vac (US)
Vin 30-64Vac (EU)

Vout 87 Vac (US)
Vout 60 Vac (EU)

RF PASS
5-1000 MHZ

9



MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK.



INCREASING THE POWERING AREA COVERED BY POWER SUPPLY


Slide 10

Power Booster – the 4G Transmission
New Power Booster 4G
RF PASS 1GHZ

10

 Integrated Dual Power inserter.
 Stand alone unit.

coverage area

 Voltage gain 1: 1.56 enabling up
to double powering distance.

Technology

 Zero crossing - Smooth transition
between conversion levels.

AC/AC transformation gears

 4 Automatic gears

Self current load

 100 mA (EU model)
 200 mA (US model)


Slide 11

US PATENT 8,415,822
Unlimited backup Power for Optical & HFC networks Without Batteries



All in One two-way RF Pass 1GHZ passive device that “toggle” available
power between two distant locations.
Redirecting power from the "normally" remote powered area to the
area subject to power outage.
During the normal mode of operation, when there is no power outage
at either end of the pair, the SYNERGY-2 act as power
block to the other side.
Utilizing breakthrough step-up & stabilizing voltage technology the unit
provides optimal & stable voltage level from local or
remote P.S even from very long distance or using a un-stabilized P.S.






=

To remote / Node
/ Amplifier

Power
+
Signal

1
2

11

AC 1 input.
AC 2 input

1

P.S

2

3

3
4

Optical
Node/Trunk
amp

4

Backup IN.OUT (AC+RF to remote Node/ amp)
Local output to local Optical Node.(AC+RF)

DPS V 4

+
Power Booster


Slide 12



Inside view : SYNERGY-2 60/87V -2x15A
Inputs/ Output configuration

Monitoring
Inputs/outputs
ONLINE Current &
Voltage + status.

US PATENT 8,415,822

AC 2 - Input

RF / AC
5-1000Mhz 15A
INPUT / OUTPUT
To / From Remote
Amplifier / Node

RF / AC
5-1000MHz 15A
OUTPUT To Local
Amplifier / Node

v

v
t

Vin 30-87V Vac (US)
Vin 30-64V Vac (EU)

12

AC1 - Input

t
Vout 87 Vac (US)
Vout 60 Vac (EU)


Slide 13

SYNERGY 2 the New generation.
DPS Ver 4

Improved – Integrated power Booster
(ALL in ONE).

External Power Booster required depend
on voltage level when using remote
powering.

Limited by cable conductivity and
Voltage drop.

Required stabilizing
P.S. (Ferro or T-former)

Required stabilizing
P.S. (Ferro or T-former)

Integrated Dual Power inserter.

Integrated Dual Power inserter.

External Dual power Inserter is
needed

Installation

One unit.

One unit. (+ optional Power Booster)

Required Two units.

Monitoring

Direct Monitoring outputs
Via one Cable to IP transponders.

Direct Monitoring outputs
Via one Cable to IP transponders.

---

Remote backup powering

Stabilizing Voltage

Power Insertion


13

Previous generations
of DPS

SYNERGY-2

Improved .
No required stabilizing P.S.
Build in online zero crossing voltage
stabilizer.

Unlimited backup Power for Optical & HFC networks Without Batteries


Slide 14

US PATENT 8,415,822

NEW UR – Ultra Range +/- 25% Vin

a
a
a
a
a
a

14

a


Slide 15

Dual Port P.S model SC-D-TFPS-1800-E-O-M
2 ports X 15A 60,75,87Vac 50/60 Hz.
External Monitoring
DPS, SYNERGY-2 & more
Direct RF connection
to CATV network

Voltage testing points

DOCSIS® & EuroDOCSIS Status
Monitoring Embedded
Transponder.

Current loop testing
points
(For Clamp meter)

15

Output 1
60,66,72 15A
Direct
connection.

Output 2
60,66,72 15A
Direct
connection.


Slide 16

NEW-Dual Port P.S model SC-D-TFPS-1800-EOM
2 ports X 15A 60,75,87Vac 50/60 Hz.

16


Slide 17

NEW-Dual Port P.S model SC-D-TFPS-1800-UOM
2 ports X 15A 60,75,87Vac 50/60 Hz.

Current testing points

Voltage testing points

External Monitoring
DPS, SYNERGY-2 & more

Direct RF connection
to CATV network

Phase changer
DOCSIS® & EuroDOCSIS Status
Monitoring Embedded
Transponder.

120 KA SURGE
SUPPRESSION

Secondary AC input /
Generator
Output 1
60,66,72 15A
Main AC input

17

Direct
connection.

Output 2
60,66,72 15A
Direct
connection.


Slide 18

NEW-Dual Port P.S model SC-D-TFPS-1350-90UI
2 ports ,15A 60,75,87Vac 50/60 Hz.

 For hanging or shelf-lain mounting.
18

CATV Dual Port P.S 1350VA 15A 60,72,87V


Slide 19



Unlimited backup Power for Optical & HFC networks Without Batteries

SYNERGY-2 Typical configuration Optical
node + Trunk amplifier(or second optical node).

60V
1
Power +
Signal

To remote /
amplifier /
Node

3

Area A

60V

From Optical
node

Area B
19

P.S

60V

1

2

3

4

Optical Node
Or Trunk amplifier

4

P.S
.S

Power + Signal

2

1
2
3
4

Optical Node

60V

AC 2 input.
AC 2 input
Backup IN.OUT (AC+RF to remote Node/ amp)
Local output to local Optical Node.(AC+RF)


Slide 20



Unlimited backup Power for Optical & HFC networks Without Batteries
SYNERGY-2 – Demo backup power from Area A to Area B

50V

60V

55V

1
Power +
Signal

Area A

40V

Power + Signal

60V

1
From Optical
node

20

3

2

40V
3
P.S

60V
4

Optical Node
Or Trunk amplifier

4

P.S
.S

45V

Area B

To remote /
amplifier /
Node

2

1
2
3
4

Optical Node

60V

AC 2 input.
AC 2 input
Backup IN.OUT (AC+RF to remote Node/ amp)
Local output to local Optical Node.(AC+RF)


Slide 21



Unlimited backup Power for Optical & HFC networks Without Batteries

SYNERGY-2 – Demo backup power from Area B to Area A

50V

40V

45V

60V

1
Power +
Signal

Area A

60V

Power + Signal

60V

1

2

3

4

To Optical node

21

3

P.S

Optical Node
Or Trunk amplifier

Optical Node

4

P.S
P.S
.S

55V

Area B

From remote
amplifier / Node

2

1
2
3
4

AC 2 input.
AC 2 input
Backup IN.OUT (AC+RF to remote Node/ amp)
Local output to local Optical Node.(AC+RF)


Slide 22

SAFECOM’s powering system around the world.
Reliability since 1994

22


Slide 23

Power backup Comparisons

23

Power Type

Standby + Batteries

Non Standby

Generators

Synergy-2 / DPS V4
T-Former

Cost

High

Low

High

Low

Maintenance

Permanent

Negligible

Permanent

Zero

Backup Power

(Depends on batt.
condition )

None

Limited by fuel

Unlimited

Redundant/ Diversity

Very Expensive

Low

Very expensive

Low cost

Integrated Surge
Suppressor 120K

NON

NON

NON

Optional

Integrated Phase
Changer

NON

NON

NON

Optional

2 to 3 hour


Slide 24

Typical optical network powering
examples

24


Slide 25

90V-network
60V-available

25


Slide 26

HFC Network 90V- DPS5+ Power Booster backup power
60V-network
90V-available

26

90V-network
60V-available


Slide 27

HFC Network 90V- DPS5 backup power
90V-network
60V-available

27


Slide 28

Business case.
 Improving customer service and satisfaction.
 Enabling MSO to add new services that required top high
reliability.
 Unlimited backup time.
 Reducing dramatically CAPEX & OPEX.
 Increasing powering efficacy & save energy.

28


Slide 29

DOCSIS® & EuroDOCSIS Status Monitoring
Complete Tree-View Import using CSV file
• Also can discover One node at a time from the UI (on –demand discovery )
• Network discovery
• Export the Tree-View for further Use
1. Discovery can be backed up
2. Automated Full Topology DPS/ SYNERGY back up
Auto Discovery of the PS Monitor
• Supports any device that has a SCTE-HMS-PS-MIB
• Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB )
• Auto Generates Attribute Widgets with properly formatted thresholds
• Supports all Adjacent devices like APC, Cordex Controllers etc.
• Supports Discrete Thresholds

29


Slide 30





30

Monitors the Attributes
– Pre-Configured Poll Interval
– Summarization ( Hourly , Daily )
– Graphing ( Single or Multiple attributes )
– Attribute Refresh ( on demand )
Monitors the Current Alarm Table
– Generates the Events from this table
– Auto Correlation ( If the alarm is pre-existing, does not generate a new
Alarm)
– Updates the Tree-view with corresponding Severity
– If SNMP Traps are enabled, It will auto-correlate the incoming traps with
Current Alarm table


Slide 31

Google Maps Integration

31


Slide 32

ON-LINE REPORT

32


Slide 33


DPSv4 / SYNERGY-2/ Power Booster
Standard Features
 Europe 60V & US 90V Standard.
 Support full 15A rms input /output.
 Prefect voltage at the remote location in the network.
 †Water-proof Enclosure.(IPX8)
 Opposite connection protected.
 †Input & Output Surge Protection.
 DOCSIS® & EuroDOCSIS Status Monitoring.
 Online RF transmission during operation. (INTERNET,VOD,VOIP)

33


Slide 34

Summery
 SAFECOM SYNERGY-2 & DPSv5 & Power Booster offers CATV operators the most
efficient and reliable complete backup solution for unlimited time at minimum
cost.
 No additional cost for MSO further to the fact that SYNERGY-2 / DPS v4 unit can
be reuse from HFC network to full optical network.
 Following the government regulation for full powering backup.
 SYNERGY-2 ,DPSv5 & Power Booster systems enabling additional backup from
remote powering.
 No maintenance.
 Unlimited life time.
 Two way powering on a single cable (Coax or electrical cable)
 Full DOCSIS® & EuroDOCSIS Status Monitoring

34


Slide 35

Thank you

35