Presentación de PowerPoint

Download Report

Transcript Presentación de PowerPoint

Slide 1

Seguimiento en línea de la vinificación usando un
sistema de inyección en flujo
P. Pérez Juan 2; J. González-Rodríguez1; and M.D. Luque de Castro 3
(1) R & D Department, Pérez Barquero S.A., Avda. de Andalucía 27, E-14550 Montilla (Córdoba) Spain
Phone: 34-957650500, Fax: 34-957650208, e-mail: [email protected]
(2) LIEC, Laboratory and Enological Research of Castilla, Polígono industrial. Calle XV, parcela R-113, E-13200
Manzanares (Ciudad Real), Spain. Phone: 34-926647115, e-mail: [email protected]
(3) Analytical Chemistry Department, Annex C-3, Campus of Rabanales, University of Córdoba, E-14071 Córdoba, Spain
Phone: 34-957218615; e-mail: [email protected]

Introduction
An approach for on-line monitoring of the alcoholic fermentation (alcohol degree, volatile acidity, total phenols and anthocyans index, catechins, readily
assimilable nitrogen, urea and ammonium) is proposed. These are the main parameters monitored in fermentation processes in order to both obtain a quality
product and avoid any problem during the fermentation stage or subsequent stages, for red and white wines and must. The methods have been characterised in
terms of dynamic linear ranges (0-12% for alcoholic degree, 0.02-1 g of tartaric acid/l for volatile acidity, 20-70 units for total phenols and 20-500 mg/l for
anthocyan index, 10-250 mg of gallic acid/l for catechins, 15-400 mg/l for readily assimilable nitrogen and 0-25 mg/l for both urea and ammonium), repetitivity,
reproducibility and limits of detection and quantification. The full automation of the methods can be achieved by a computer provided with the appropriate
software and active interfaces for controlling both pumps and valves and passive interfaces for collecting the data from the detectors. The on-line monitoring of
the target parameters is thus performed at the required frequency.

Readily Assimilable Nitrogen

Abbreviations:
PP: Peristaltic Pump, R: Reactor, D: Detector, m: membrane
IV: Injection Valve, SV: Selection Valve, TB: Thermostatic Bath
W: Waste

Total Phenols and
Anthocyans

Urea and Ammonium

FLOW
Grape

PROCESS

Reception of Raw material
Pre-fermentation

New wine

Urea
Readily Assimilable Nitrogen

Fermentation process

Red wines: Anthocyans, Catechins
Total Phenols

New wine maduration

Ethanol, Urea, Volatile Acidity,
Ammonium. Red wines: Catechins,
Anthocyans, Total Phenols

Vintage wine
Catechins

CONTROL

Ageing

Ageing wine

Final processes

Market

Ethanol, Urea, Volatile Acidity,
Readily Assimilable Nitrogen
Red wines: Total Phenols, Anthocyans,
Catechins
Ethanol

Volatile Acidity

Analytical features
Methods
Parameter

Ethanol

Volatile
Acidity

Total Phenols

Anthocyans

Catechins

Assimilable
Nitrogen

Urea

Ammonium

Ref.

FI

Ref.

FI

Ref.

FI

Ref.

FI

Ref.

FI

Ref.

FI

Ref.

FI

Ref.

FI

Repeatability

0,13

0,26

0,033

0,038

1,021

2,122

4,232

6,233

3.10

2.57

4.10

1.35

0.185

0.523

0.123

0.432

Sr (g/l)

0,05

0,15

0,012

0,013

0,032

0,043

0,061

0,081

0.56

0.45

0.67

0.472

0.066

0.098

0.041

0.065

Reproducibility

0,29

0,31

0,042

0,046

2,312

3,012

9,232

12,21

5.30

3.56

6.30

3.94

0.214

1.345

-

1.212

SR (g/l)

0,09

0,19

0,015

0,016

0,091

0,123

0,802

1,083

1.02

0.95

1.98

1.23

0.076

0.132

-

0.12

r

-

1,66

-

1,32

-

1,81

-

1,76

-

0.646

-

0.497

-

2.205

-

2.489

FobsR

-

1,49

-

1,18

-

1,83

-

1,82

-

0.867

-

0.386

-

3.017

-

-

F1-α

-

1,69

-

1,84

-

1,84

-

1,84

-

1.69

-

1.69

-

4.24

-

4.24

LOD

0,02

0,01

0,041

0,032

0,231

0,229

0,953

0,543

2.2

4.5

8

10

0.15

0.9

0.08

0.6

LOQ

0,07

0,03

0,084

0,086

0,455

0,530

1,380

1,110

6.1

5.85

9.4

11.6

-

1.02

-

0.67

Samples h-1

3

7

5

10

40

50

3

25

3

23

2

20

9

15-16

9

15-16

Fobs

Units

Ethanol: % (v/v); Volatile Acidity: g tartaric/l; Total Phenols: Abs units; Catechins: mg gallic/l; Anthocyans, Assimilable Nitrogen, Urea and Ammonium: mg/l

Conclusions
FI methods are simple, unexpensive and easy to implement
Pervaporation allows on-line
shortcomings of gas diffusion

monitoring

without

High sampling rates and no pretreatments are needed
Good correlation with the reference methods

the