Odorless Pathology Laboratories is Possible! www.zenonmed.com PROBLEMS ENCOUNTERED Lack of grossing station Ventilation problems Inappropriate storage conditions of tissues Preparation and usage problems of laboratory chemicals Hazardous.
Download ReportTranscript Odorless Pathology Laboratories is Possible! www.zenonmed.com PROBLEMS ENCOUNTERED Lack of grossing station Ventilation problems Inappropriate storage conditions of tissues Preparation and usage problems of laboratory chemicals Hazardous.
Odorless Pathology Laboratories is Possible! www.zenonmed.com PROBLEMS ENCOUNTERED Lack of grossing station Ventilation problems Inappropriate storage conditions of tissues Preparation and usage problems of laboratory chemicals Hazardous waste management Representative View for an Inappropriate Laboratory STEPS FOR SOLUTION Grossing Station Central Ventilation System Ventilated Storage Cabinet Fully Automated Preparation and Usage of Chemicals Monitoring of Formaldehyde and Xylene Neutralization of Hazardous Waste Meet OSHA Standards SOLUTION STEP 1 GROSSING STATION Grossing Station All stainless steel construction, ANSI 304 Working table is made of stainless steel, ANSI 316 All functions work by both photo sensors and buttons Formalin faucet and sink Backdraft and/or downdraft ventilation removes fumes safely Lit directly to the working area Photo sensors controls for cold and hot water faucet Water jet controlled by button and sensor for washing work area Formalin sink is connected to a seperate waste tank Magnifier, magnetic bar, paper towel dispenser, medical glove box holder, meausuring rule, heavy-duty disposal unit The device has safety features such as electrical leak relay, circuit breaker, emergency stop button and isoloted grounding plug Optional accessories Grossing Station Grossing Station Grossing Station SOLUTION STEP 2 CENTRAL VENTILATION SYSTEMS Central Ventilation Systems It is possible to collect the problem in two headlines: Lack of ventilation system Insufficient ventilation system • Separete exhaust ventilation for each grossing station • Charcoal filter • Inaccurate vacuum and blow Central Ventilation Systems The main points of a proper ventilation system: Installation of a central ventilation system Detached system Proper aspiration Correct engineering calculations and application Central Ventilation Systems FALSE CORRECT Merkezi Havalandırma Click to edit text styles Edit your company slogan SOLUTION STEP 3 VENTED STORAGE CABINET Vented Storage Cabinet All stainless steel construction, ANSI 304 Adjustable perforated shelves Fixed or telescopic shelf structure Sliding or standard door Liquid collector Connection with ventilation system or separete exhaust Vented Storage Cabinet SOLUTION STEP 4 Fully Automated Preparation and Usage of Chemicals Exposure of Formaldehyde During dissection practice Preparation of formaldehyde from paraformaldehyde Preparation of formalin Transfer of tissue into formalin Transfer of waste formalin into waste tank Spill of formalin Exposure of Formaldehyde During dissection practice Preparation of formaldehyde from paraformaldehyde Preparation of formalin Transfer of tissue into formalin Transfer of waste formalin into waste tank Spill of formalin Exposure of Formaldehyde Obtain ready to use formalin Use an preparation machine Ready to Use Formalin Advantages Less exposure compared to the manuel applications Much more standardized in comparison to preparation by manually Turnaround times for valueadded work Disadvantages High costs Transportation needed to the lab frequently Risk of formalin sediment in the package Storage problems Automated Formalin Preparation and Dispensing System Advantages Significant reduction in costs User safety :Avoid inhaling or having contact formaldehyde Consistency Obtaining formalin directly from tap Odorless working enviroment Real time monitoring of pH Disadvantages Initial investment needed FormaDose The first fully automated device in the market 10% factory set or used defined dosing options Monitoring the level of formalin on the screen Precise dosing in every time Automatic and manual mixing functions Real time monitoring of pH Screw filler cap to add salts for preparation buffred 10% formalin Connection to the grossing stations Exposure of Xylene While working with staining and coverslipping instruments During manuel staining and coverslipping practice During the replacement of tissue processor’s solutions FUME HOOD INSTRUMENT VENTILATION CABINET INSTRUMENT VENTILATION CABINET Project Designing Visit Examine Get Results Project Design Application Project design Click to edit text styles Edit your company slogan Projelendirme Central Ventilated Unit Click to edit text styles Edit your company slogan Customized Solution for Your Laboratory Workbenches You can create flexible work spaces by benches which we produced by using stainless steel, laminate, acrylic or stoneware specific to your needs in accordance with characteristics of the chemicals used in laboratories. Custom Design Work Tables Work tables designed for use in laboratories which have narrow work environment will facilitate your work by functional solutions. Cabinets with Shelves It is possible to create a laboratory environment that is up to standard and in order with rack systems according to your needs.