4100 Series Eurotherm Chessell’s New 100mm Recorders Highlights • Six new 100mm recorders offers widest choice of features and prices: – 1-4 Pen Continuous recorders. – 6 input Multipoint recorders. •

Download Report

Transcript 4100 Series Eurotherm Chessell’s New 100mm Recorders Highlights • Six new 100mm recorders offers widest choice of features and prices: – 1-4 Pen Continuous recorders. – 6 input Multipoint recorders. •

4100 Series
Eurotherm Chessell’s
New 100mm Recorders
1
Highlights
• Six new 100mm
recorders offers widest
choice of features and
prices:
– 1-4 Pen Continuous
recorders.
– 6 input Multipoint
recorders.
• Choice of displays:
– Classical Analogue.
– Simple Digital
– 4 colour Digital/ Analogue.
• Embedded Technology:
– Custom D/A converters.
– High speed Multipoint printing
head.
– Annotation for both
Continuous and Multipoint.
– PCMCIA card readers.
– µ processor with powerful data
handling.
• Compact size.
• Common Mechanics.
2
4100 Series
Model No
Type
Displays
4101C
Continuous
Analogue
4101M
Multipoint
Analogue
4102C
Continuous
Simple Digital
4102M
Multipoint
Simple Digital
4103C
Continuous
Advanced Digital
4103M
Multipoint
Advanced Digital
Price
Lowest
Highest
3
Common Technologies
•
•
•
•
•
•
•
1-4 pen continuous & 6 input Multipoint.
Compact size.
Universal Isolated inputs.
Annotation.
State of the art mechanics.
Universal Power Supply (90-260Vac)
Fan-Fold cassette.
4
Compact Size
144 mm
0
0
144 mm
- 10
2 0
2 0
5 0
0
4 0
4 0
1 00
1
0
6 0
6 0
144 mm
8 0
1 00
8 0
1 00
1 50
2 00
2 50
2 0
3 0
236 mm
220 mm
200 mm
4 0
4101 Front v iew
144 mm
0
27
mm
137
mm
C ase clamp
4102/3 Front v iew
Maximum panel
thickness = 25 mm
Terminal cover
View on right hand s ide
• Din Standard 144X144 mm fits installed base of
recorders.
• Standard cut-out for the complete range.
• Small depth behind panel allows for installation in
250mm deep cabinets.
• Weight = 5kg
5
Universal Inputs
dc Volts
- 2 to 10V
-20 to 100V
with attenuator
•
•
•
•
•
•
dc mA
0 to 20 mA
T/C
RTD
B,C,E,J,K,N,R, Pt100ANSI,
S,T.
DIN,JPT100
Ni/Ni Mo 18% Ni 100 & 120
Custom chipset gives one converter per channel.
Wide range of input types.
250V isolation channel to channel & ground.
High stability due to digital design.
Universally calibrated to allow re-ranging later.
Input accuracy 0.2%.
6
Annotation
• Available on the complete range.
• Avoids use of custom overprinted charts.
• High speed annotation.
– Uses dedicated print system on Continuous.
– High speed Multipoint printer allows fast text printing.
7
Mechanical Innovation
Motor Assembly
Multipoint Printer
• Contactless Feedback & Motor.
– No wear & tear.
– High noise immunity.
19
• Multipoint Printing
– Few moving parts = Higher reliability.
• No mechanical adjustments
– For higher reliability and longer calibration intervals.
8
4101 Basic Recorder
4101C
• High Pen Visibility.
• Analogue Display.
• Pre-configured to user’s
specifications.
• Front access to
electronic pen zero/span
adjust.
• Overall accuracy 0.5%.
• Ready to go.
4101M
9
4101 Charts
• Continuous:
– Highest quality of trace.
– High speed variables.
• Multipoint:
– Economic for 4 to 6 inputs.
– Slower moving variables.
10
4101 Application
• Plant History:
– Any continuous process.
• Machine Monitoring:
–
–
–
–
–
Sterilisation processes.
Turbines.
Furnaces.
Electricity usage.
Test Chambers
• Where a simple, reliable
recorder is needed for
trending of a variable.
• Trends are all important not
absolute values.
• Instrument configuration
will not change.
• Price is all important.
• Environmental
Monitoring:
– Weather.
– Simple analytical.
11
4102 Digital Recorder
•
•
•
•
4102C
4102M
•
•
•
•
•
•
3 colour Digital Display.
Annotation.
Chart Illumination.
Front Access to pen
zero/span adjust.
Pre-configured to user’s
specifications.
PC configuration.
4 to 12 relay outputs.
2 to 4 analogue O/P.
Overall accuracy 0.5%.
Ready to Go.
12
4102 Display
Channel
number
Alarm
annunciators
Display
hold indicator
Measured variable
•
•
•
•
•
3 Colour Display
Large 4 digit display of process values.
High / Low alarm annunciator.
Channel Indentification.
0.2% Display accuracy.
13
4102 Application
• Plant History:
– Any continuous process.
• Machine Monitoring:
–
–
–
–
Sterilisation in line processes.
Turbines.
Furnaces.
Electricity usage.
• Digital display is needed to obtain
accurate values of the measured
variables.
• Where a simple, reliable recorder
is needed.
• There is occasional need for
reconfiguration.
• Environmental Monitoring:
– Weather.
– Simple analytical.
14
4102 PC- Configuration
• Simple Channel by Channel Configuration.
• Uses standard PC with special RS232 cable.
• Allows filing of instrument configurations on Hard Disk.
15
4102 Annotation
•
•
•
•
Time & Date stamping.
Zero and Span values.
Channel identification.
Engineering units.
• Continuous recorder has
dedicated print head.
• Multipoint recorder uses 6
colour print head.
16
4103 Intelligent Recorder
4103C
4103M
•
•
•
•
•
•
•
•
•
•
•
4 - Colour Digital Display
User Programmable.
Annotation.
Universal Isolated I/P.
Chart Illumination.
Mathematical Data
processing.
Communications.
4 to 16 relay O/P.
2 to 4 Analogue O/P.
16 Contact I/P.
Overall Accuracy 0.25%.
17
4103 Display
1 2
3 4
5 6
C h a n n e l
T a g
U n i t s
1
2
3
4
4
5
6
5 0
A l a r ms : 1 ^
•
•
•
•
•
mA
2 ^
1 0 0
3
4
Versatile four colour VFD display.
Easy to use programming keys.
Clear multilingual programming prompts.
Comprehensive alarm summary.
20 character custom message.
18
4103 Universal Inputs
dc Volts
- 2 to 10V
dc mA
0 to 20 mA
-20 to 100V
Programmable
with attenuator Shunt.
Ohms
Custom Lin.
0 to 9000 Ohms 32 segments
T/C
B,C,E,J,K,N,R,
S,T.
Ni/Ni Mo 18%,
L, U, Platinel
RTD
Pt100ANSI,
DIN,JPT100
Ni 100 & 120,
Cu10, Pt 1000
Flow Lin.
, X 3/2, X 5/2
Digital
> 60 ms
• Custom chipset gives one converter per channel
– 8x per second update , 2x per second 4103M
• 250V isolation channel to channel to ground
• High stability due to digital design
• Digital accuracy 0.1%
19
4103 Advanced Features
• Grouping of process variables:
– Allows group orientated computation.
• Comprehensive mathematical processing.
• Alarm Monitoring.
• Application orientated timers, counters,
totalisers.
• Job orientated logical functions.
• Input and paper calibration
20
4103 Logs / Alarms
• Alarm Functions:
– 4 alarms per channel:
» Absolute High/Low.
» Deviation In/Out.
» Rate of change.
– Text messages on alarm
– Message to display for
operator action
• Logging:
– Columnar of group data.
– Custom messages with
embedded data:
» Time
» DV’s
» Process Variable
21
Timer / Counters/Totalisers
6 of each
• Time:
– Alarm on absolute time
– Alarm every:
» Minute
» Hour
» Day
» Month
» Year
• Counter:
(Input is any Job or Contact)
Increment from start position.
– Decrement from start position.
– Reset.
– Alarm at any value.
– 8 Digit resolution.
• Totaliser:
(Any analogue input)
– As above but integrating.
– Integration time & unit scalar
programmable.
22
Mathematical functions
(12 DV’s 4103C, 16 DV’s 4103M)
• Basic - (level 1):
–
–
–
–
–
Constant.
Copy.
Add & Subtract.
Divide & Multiply.
Modulus.
• Advanced - (level 2):
– Maths:
» Square Root.
» Loge & Log10
» ex & 10x
» Rate of Change.
» 3rd Order Polynomial.
– Timers
• Advanced:
– Statistical:
» Average Channel or
Group.
» Rolling Average.
» Sample & Hold.
» Channel Min & Max.
» Group Min & Max. (latched
/ continuous)
» High/Low select.
– Specials:
» Relative Humidity.
» Fo Value.
» Mass flow.
» Zirconia Probe.
23
Jobs
• Triggered by:
–
–
–
–
Channel Alarm.
Totalisers & Counter threshold.
Timers.
Events:
» Instrument alarms.
» Digital Channel.
» Event Input.
• Actions
– Printing:
»Chart on/off.
»Alternate Chart speed.
»Print Log,scales or Custom Message.
»Change channel range.
– Resetting:
»Reset DV’s (1 or all).
»Reset/Preset Timer etc..
– Others:
»Drive relays or buzzer.
»Inc. / Dec. Counter.
»Start / Stop Timer.
»Memory card control.
»Alarm messages to display
24
4103 PCMCIA Card
Tank Monitor
15/9/95
15/9/95
15/9/95
15/9/95
15/9/95
15/9/95
15/9/95
10:00:01
10:00:02
10:00:03
10:00:04
10:00:05
10:00:06
10:00:07
In Temp In Flow Out Flow Tank Lev el
Deg C
L/Sec
L/Sec
Meters
22.05
56
55
50.00
22.05
56
55
50.01
22.05
56
55
50.03
22.05
56
55
50.04
22.05
56
55
50.05
22.05
56
55
50.06
22.05
56
55
50.06
Total
Liters
1050000
1050010
1050020
1050030
1050040
1050050
1050060
Messages
Tank Lev el High
• Storing and/or transferring Configurations.
• Storing Logs and alarm messages as part of a Job.
• Storing at pre-set intervals for transfer to PC spreadsheet or
database.
• Chart Copy to re-print charts.
• Packed data for greater storage in a secure format
25
4103 PC- Configuration
• Simple Channel by Channel configuration
• Can be done off-site on PC:
– Using PCMCIA card to transfer data
– Incorporating a configuration print -dump
– Allows multiple configurations to be stored
– Ideal for complex configurations
26
4103 Communications
• Physical Layer:
– RS485 (compatible with RS232):
» Allows for up to 8 multidrop ports.
– Up to 19200 Baud.
• Protocol:
– MODBUS RTU ®.
• Allows :
– Transfer of measured variables to master.
– Transfer of data from master:
» To be plotted as a channel.
» Used as variable in Maths operations.
» Used as an alarm set point.
27
4103 High Definition Tracing
Multipoint
•
•
•
•
•
•
•
6 colour traces updated each
second.
Interpolation.
Adaptive recording.
Line thickening.
User configurable tags.
Flexible zoning & scaling.
Text or trace priority modes
and text only.
28
4103 High Definition Tracing
Continuous
•
•
•
•
•
Pen offset compensation.
Flexible zoning & scaling.
Dedicated print head for
annotation.
Derived 5th Channel
Multipoint printing.
Text or trace priority modes.
29
4103 Application
• Process plant:
– Mass flow totalisation.
– Plant monitor.
• Machine Monitoring:
– Heat treatment.
– Sterilisation validation.
– Any machine QA
documentation.
• Environmental
Monitoring:
– Continuous Emission
monitoring.
– Relative Humidity
calculations.
– Multi stream analysis
• Where a complete log of the
process is required to be
used as a transaction
document.
• Where communications are
required with a central unit
or SCADA package.
• Where PC after the event
processing or analysis is
required.
• When configuration change
is frequent or uncertain at
time of order.
30
Summary
Continuous Pen
Multipoint Dotter
Digital Display
Programmable
Annotation
Relay Outputs
Retransmission O/P
Contact Inputs
Communications
Memory Card
Chart Lighting
PC Configuration
Mathematics
Counters, Totalisers,Timers
4101C
•
4101M
•
•
•
•
•
4102C
•
4102M
•
•
•
•
•
•
•
•
•
•
•
•
•
4103C
•
•
•
•
•
•
•
•
•
•
•
•
•
4103M
•
•
•
•
•
•
•
•
•
•
•
•
•
• The 4100 series is designed to offer the user a
wide choice of features and costs.
31