Multi Functional Digital Fault Recorder INTRODUCING THE BLACKBOXDFR Fully Featured Digital Fault Recorder For Transmission & Distribution Substations Multi-Functional PMU Class A Power Quality Monitoring Single.
Download ReportTranscript Multi Functional Digital Fault Recorder INTRODUCING THE BLACKBOXDFR Fully Featured Digital Fault Recorder For Transmission & Distribution Substations Multi-Functional PMU Class A Power Quality Monitoring Single.
Multi Functional Digital Fault Recorder INTRODUCING THE BLACKBOXDFR Fully Featured Digital Fault Recorder For Transmission & Distribution Substations Multi-Functional PMU Class A Power Quality Monitoring Single or Double Ended Impedance-Based Fault Location Energy Metering 24 Bit Continuous Acquisition @ 1024 Samples Per Cycle 0.1% Accuracy on Analog Channels Class A Power Quality 0.1% Power & Energy Accuracy … Surpassing: IEC 62053-22 Class 0.2S ANSI C12.20 02 Class 10 + 20 for Energy 1 μsecond Time Synchronization Highly Accurate PMU Measurements BUILT-IN WEB SERVER GENERAL OVERVIEW Full Measurement & System Status RMS THD Trends System Information System Status Events INVESTIGATION 10,000 Parameters over 16 Analog & 96 Digital Channels: 1 μsecond Zoom Monitor Network System Condition Detect Instabilities Predict Future Failures Scopes, Trends, Statistics, Summaries, Spectrums … EVENTS Digital Input OR PQ Events: Dips, Swells, Interruptions, Transients, DI …. Custom Events Exceed Limitations Parameters DX/DT Event Aggregation Logic Operator AND, OR, XOR WEB-ENABLED DEVICE FULLY FEATURED WEB SERVER - HTML5 WEB TECHNOLOGY Utilizing …. Widely Used Web Browsers: Firefox Internet Explorer Safari & more … Common Smart Devices: Android iOS Windows 8 REAL-TIME MONITORING 5” COLOR TOUCH LCD 1 Point Access in Real-Time: All System Functions Configurations Measured Values Interactive: Easy to Operate Full Color User-Friendly Interface SYSTEM ARCHITECTURE LAN (PQZ, IEC 61850, DNP3, MODBUS) GPS/IRIG B Serial Port 2 x Synch Ports Power Quality PMU Metering Event Detection Fault Locator 5” Color Touch LCD 1 Year Waveform Recording 10,000 PQ Parameters 2 x USB Ports IR Port (Metering/Maintenance) Digital I/O Sensor Inputs 16 AC/DC Analog Inputs 20µs – 2 Hrs Resolution Metering ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY FRONT VIEW 1 LCD Touch Screen 2 Handles 3 IR Data Port ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY REAR VIEW Communication Ports Custom Modular Design PPS / IRIG B Port 1 6 RS485/422 Serial Port 2 7 Up to 16 Analog Channels 2 x DSP Sync In & Out Ports 3 8 Up to 96 Digital Channels LAN Port 4 2 x USB Ports 5 Spare Slot 9 Main Power ON/OFF Switch 10 Main Power Inlet Socket PORT CONFIGURATIONS Voltage Analog Inputs: 0, 4, 8, 12, 16 Current Analog Inputs: 0, 4, 8, 12, 16 Digital Status [In] 0 to 96: Increments of 32 Control Output 0 to 48: Increments of 16 LAN Port: 1 Serial Port: 1 IR Port: 1 PPS Time Sync: 1 USB Ports: 2 DSP Sync: 2 [In & Out] PHYSICAL DIMENSIONS REAR VIEW FRONT VIEW FRONT VIEW SIDE VIEW REAR VIEW DIMENSIONS (W x H x D) EXCLUDING ENCLOSURE Single 21.5 x 22.1 x 29.1cm (8.48 x 8.7 x 11.45”) Double 43.1 x 22.1 x 29.1cm (16.96 x 8.7 x 11.45”) DIMENSIONS (W x H x D) INCLUDING ENCLOSURE Single (Side Empty) & Double 48.3 x 22.1 x 29.1 cm (19 x 8.7 x 11.45”) TIME SYNCHRONIZATION GPS/IRIG B 1 µsec Accuracy to the Master Clock SNTP 100 µsec Accuracy to the Master Clock DSP SYNCHRONIZATION 100 nsec Between Modules DIGITAL FAULT RECORDING 1 Year Continuous Waveform Recordings 1,024 Sample/Cycle per Analog Channel (50/60Hz) 128 Sample/Cycle per Digital Channel (50/60Hz) Unlimited Triggers Digital Input Change Analog Exceed Limitations Parameters DX/DT Fault Locator One Ended Impedance-Based: Designed for Locating Faults on Single-Circuit Lines Two Ended Impedance-Based: Designed to Measure Two-Ended Synchronized Recordings of Voltage & Currents, Formulating Frequency Phasors of Symmetrical Components CLASS A POWER QUALITY Measure & Record More Than 10,000 Parameters Unbalance 511 Harmonics Inter-Harmonics THD RMS & More … Power Quality Events Voltage Dips Voltage Swells Voltage Interruptions CLASS A POWER QUALITY Custom Events Per any Measured Parameter DX/DT for any Measured Parameter Transient Events Event Capture per Waveform Signal Compliance Engine EN50160 Custom Compliance – Geared to Meet any Grid Code PHASOR MEASUREMENT UNIT (PMU) Measurement of Vector Quantities: Highly Accurate According to IEEE C37.118 – 2005 1µsec Time Synchronization On-Board Solution: Continuous Phasor Recording and Transmitting ½ Cycle Transmission Rate ENERGY METER Integrated High Precision Energy Meter – Measure & Record: 0.1% Power & Energy Accuracy … Surpassing: IEC 62053-22 Class 0.2S ANSI C12.20 02 Class 10 + 20 for Energy Flow of Energy within a System: Reactive Power Active Power Apparent Power Power Factor Flow of Power To & From the System to the Grid: Delivered Received BLACKBOX ARCHITECTURE PQSCADA 5 – OVERVIEW [SINGLE MAP] PQSCADA 5 – OVERVIEW [MULTIPLE MAPS] PQSCADA 5 – OVERVIEW [ELECTRICAL MAP] PQSCADA 5 – OVERVIEW [TOPOLOGY] PQSCADA 5 – POWER QUALITY PQSCADA 5 – POWER QUALITY PQSCADA 5 – POWER QUALITY PQSCADA 5 – POWER QUALITY PQSCADA 5 - INVESTIGATOR BLACKBOXDFR - THE PERFECT DFR SOLUTION MULTI CHANNEL – UP TO 16 ANALOG & 96 DIGITAL CHANNELS PER MODULE HIGHLY ACCURATE MEASUREMENTS ULTRA FAST SAMPLING RATE INTEGRATED DB FOR SW FREE INVESTIGATION PQZIP II – FOR REAL TIME COMMUNICATION THANK YOU