Multi Functional Digital Fault Recorder INTRODUCING THE BLACKBOXDFR Fully Featured Digital Fault Recorder For Transmission & Distribution Substations Multi-Functional PMU Class A Power Quality Monitoring Single.
Download
Report
Transcript Multi Functional Digital Fault Recorder INTRODUCING THE BLACKBOXDFR Fully Featured Digital Fault Recorder For Transmission & Distribution Substations Multi-Functional PMU Class A Power Quality Monitoring Single.
Multi Functional Digital Fault Recorder
INTRODUCING THE BLACKBOXDFR
Fully Featured Digital Fault Recorder For Transmission & Distribution Substations
Multi-Functional
PMU
Class A Power Quality Monitoring
Single or Double Ended Impedance-Based Fault Location
Energy Metering
24 Bit Continuous Acquisition @ 1024 Samples Per Cycle
0.1% Accuracy on Analog Channels
Class A Power Quality
0.1% Power & Energy Accuracy … Surpassing:
IEC 62053-22 Class 0.2S
ANSI C12.20 02 Class 10 + 20 for Energy
1 μsecond Time Synchronization
Highly Accurate PMU Measurements
BUILT-IN WEB SERVER
GENERAL OVERVIEW
Full Measurement & System Status
RMS
THD
Trends
System Information
System Status
Events
INVESTIGATION
10,000 Parameters over 16 Analog & 96 Digital
Channels:
1 μsecond Zoom
Monitor Network System Condition
Detect Instabilities
Predict Future Failures
Scopes, Trends, Statistics, Summaries, Spectrums …
EVENTS
Digital Input OR PQ Events:
Dips, Swells, Interruptions, Transients, DI ….
Custom Events
Exceed Limitations
Parameters DX/DT
Event Aggregation
Logic Operator AND, OR, XOR
WEB-ENABLED DEVICE
FULLY FEATURED WEB SERVER - HTML5 WEB TECHNOLOGY
Utilizing ….
Widely Used Web Browsers:
Firefox
Internet Explorer
Safari & more …
Common Smart Devices:
Android
iOS
Windows 8
REAL-TIME MONITORING
5” COLOR TOUCH LCD
1 Point Access in Real-Time:
All System Functions
Configurations
Measured Values
Interactive:
Easy to Operate
Full Color User-Friendly Interface
SYSTEM ARCHITECTURE
LAN
(PQZ, IEC 61850, DNP3, MODBUS)
GPS/IRIG B
Serial Port
2 x Synch Ports
Power Quality
PMU
Metering
Event Detection
Fault Locator
5” Color Touch LCD
1 Year Waveform Recording
10,000 PQ Parameters
2 x USB Ports
IR Port
(Metering/Maintenance)
Digital I/O
Sensor Inputs
16 AC/DC
Analog Inputs
20µs – 2 Hrs Resolution
Metering
ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY
FRONT VIEW
1
LCD Touch Screen
2
Handles
3
IR Data Port
ARCHITECTURE – SINGLE OR DOUBLE SYSTEM ADAPTIBILITY
REAR VIEW
Communication Ports
Custom Modular Design
PPS / IRIG B Port
1
6
RS485/422 Serial Port
2
7 Up to 16 Analog Channels
2 x DSP Sync In & Out Ports 3
8 Up to 96 Digital Channels
LAN Port
4
2 x USB Ports
5
Spare Slot
9 Main Power ON/OFF Switch
10 Main Power Inlet Socket
PORT CONFIGURATIONS
Voltage Analog Inputs:
0, 4, 8, 12, 16
Current Analog Inputs:
0, 4, 8, 12, 16
Digital Status [In] 0 to 96:
Increments of 32
Control Output 0 to 48:
Increments of 16
LAN Port:
1
Serial Port:
1
IR Port:
1
PPS Time Sync:
1
USB Ports:
2
DSP Sync:
2 [In & Out]
PHYSICAL DIMENSIONS
REAR VIEW
FRONT VIEW
FRONT VIEW
SIDE VIEW
REAR VIEW
DIMENSIONS (W x H x D) EXCLUDING ENCLOSURE
Single
21.5 x 22.1 x 29.1cm (8.48 x 8.7 x 11.45”)
Double
43.1 x 22.1 x 29.1cm (16.96 x 8.7 x 11.45”)
DIMENSIONS (W x H x D) INCLUDING ENCLOSURE
Single (Side Empty) & Double
48.3 x 22.1 x 29.1 cm (19 x 8.7 x 11.45”)
TIME SYNCHRONIZATION
GPS/IRIG B
1 µsec Accuracy to the Master Clock
SNTP
100 µsec Accuracy to the Master Clock
DSP SYNCHRONIZATION
100 nsec Between Modules
DIGITAL FAULT RECORDING
1 Year Continuous Waveform Recordings
1,024 Sample/Cycle per Analog Channel (50/60Hz)
128 Sample/Cycle per Digital Channel (50/60Hz)
Unlimited Triggers
Digital Input Change
Analog Exceed Limitations
Parameters DX/DT
Fault Locator
One Ended Impedance-Based: Designed for Locating Faults on Single-Circuit Lines
Two Ended Impedance-Based: Designed to Measure Two-Ended Synchronized Recordings of
Voltage & Currents, Formulating Frequency Phasors of Symmetrical Components
CLASS A POWER QUALITY
Measure & Record More Than 10,000 Parameters
Unbalance
511 Harmonics
Inter-Harmonics
THD
RMS & More …
Power Quality Events
Voltage Dips
Voltage Swells
Voltage Interruptions
CLASS A POWER QUALITY
Custom Events
Per any Measured Parameter
DX/DT for any Measured Parameter
Transient Events
Event Capture per Waveform Signal
Compliance Engine
EN50160
Custom Compliance – Geared to Meet any Grid Code
PHASOR MEASUREMENT UNIT (PMU)
Measurement of Vector Quantities:
Highly Accurate
According to IEEE C37.118 – 2005
1µsec Time Synchronization
On-Board Solution:
Continuous Phasor Recording and Transmitting
½ Cycle Transmission Rate
ENERGY METER
Integrated High Precision Energy Meter – Measure & Record:
0.1% Power & Energy Accuracy … Surpassing:
IEC 62053-22 Class 0.2S
ANSI C12.20 02 Class 10 + 20 for Energy
Flow of Energy within a System:
Reactive Power
Active Power
Apparent Power
Power Factor
Flow of Power To & From the System to the Grid:
Delivered
Received
BLACKBOX ARCHITECTURE
PQSCADA 5 – OVERVIEW [SINGLE MAP]
PQSCADA 5 – OVERVIEW [MULTIPLE MAPS]
PQSCADA 5 – OVERVIEW [ELECTRICAL MAP]
PQSCADA 5 – OVERVIEW [TOPOLOGY]
PQSCADA 5 – POWER QUALITY
PQSCADA 5 – POWER QUALITY
PQSCADA 5 – POWER QUALITY
PQSCADA 5 – POWER QUALITY
PQSCADA 5 - INVESTIGATOR
BLACKBOXDFR - THE PERFECT DFR SOLUTION
MULTI CHANNEL – UP TO 16 ANALOG & 96 DIGITAL CHANNELS PER MODULE
HIGHLY ACCURATE MEASUREMENTS
ULTRA FAST SAMPLING RATE
INTEGRATED DB FOR SW FREE INVESTIGATION
PQZIP II – FOR REAL TIME COMMUNICATION
THANK YOU