Totem VDR Following IMO regulations and SOLAS requirements for VDR, certain classes of vessels are required to install VDR units by July 2002. Totem.

Download Report

Transcript Totem VDR Following IMO regulations and SOLAS requirements for VDR, certain classes of vessels are required to install VDR units by July 2002. Totem.

Totem VDR
Following IMO regulations and SOLAS
requirements for VDR, certain classes of vessels
are required to install VDR units by July 2002.
Totem VDR meets and exceeds IMO Performance
standard A.861 (20), IEC 61996, IEC 60945 and
IEC 61162-1.
Totem VDR is approved by DNV.
Totem VDR (Cont.)
Totem VDR consists of:
• Protective Memory Capsule (PMC) mounted on
deck, where it can be easily retrieved by divers or
ROV’s following an incident. Totem PMC rugged
design exceeded IEC 60945 requirements for marine
going equipment
• Main Unit cabinet, placed inside the ship’s bridge,
containing a computer (PC), a monitor and UPS (Uninterrupted Power Supply).
• Replay software, which enables the retrieval and the
display of all recorded data is included as a standard
feature of the Totem VDR system.
System Overview
Totem VDR Block Diagram
The VDR Protective Memory Capsule
• Contains 2Gb flash disk, Ultrasonic
location beacon, 2 handles, and 1 cable
connection socket.
• Stores data of the last 12 hours on a
final recording medium inside the
PMC.
• Special storage capsule protects the
final recording medium.
• Designed to withstand the extreme
shock, heavy impact, high pressure
and heat, which could be associated
with a maritime incident.
VDR on board of a New Building
• Easy installation on deck by 2 simple
300mm welding.
VDR - Main Unit Cabinet
• Cabinet contains Main Unit computer
(PC), 15” monitor, keyboard, mouse and
UPS (Uninterrupted Power Supply).
• PC contains CD-W for saving data on a
CD (e.g. saving non catastrophic events).
• UPS backup provides at least 2 hours
continuous recording following a
blackout.
• Keyboard is locked inside the cabinet only authorized personal using a
password can operate it.
• Lower portion of cabinet, reserved for
cables and terminals, provides easy
installation and maintenance.
Totem VDR – System Highlights
• Eight (8) independent single audio channels, NO MIXING of
Audio channels.
• Main Unit’s PC is connected through Ethernet cable to the
Totem PMC.
• Integral CD-W (CD writer) in PC for saving of noncatastrophic data.
• PC monitor displays status of recorded items at all times
(Redundant IBS – Integrated Bridge System – information).
• Redundancy – data stored on both hard disk (of PC) and on
final recording medium (inside the PMC).
VDR-Recording Inputs
The following items are recorded (as per IMO Resolution .861(20):
Date and Time
Main Alarms (IMO Mandatory
Bridge Alarms)
Ship’s Position
Rudder Order and Response
Speed
Engine Order and Response
Heading
Hull Openings (Doors) Status
Bridge Audio
Watertight and Fire Doors Status
Communication Audio
Acceleration and Hull Stresses (if
available)
Radar Data – post display selection
Wind Speed and Direction
Echo Sounder
Totem VDR - Main Screen
Redundant IBS
Information
Save Non-Catastrophic Events Screen
Data saving and
deletion is possible at
any time
Data can be saved
on a CD or on the
computer’s hard
drive
System Configuration Screen
Displays system
configuration as
entered during
installation
VDR Password
Menu options are
restricted to authorized
persons only, requiring
a username and a
password
Alarms Screen
Always on top
Totem VDR Advantages
• Novel design allows for affordable cost.
• Open architecture design based on PC technology easily
adapted to suit any type of vessel.
• Fast installation on new buildings or retrofit, based on
product simplicity and Totem Plus experience in
Automation and Monitoring Systems.
• Easy setup during installation.
• Faster annual inspection then most VDR’s in the market.
Totem VDR Advantages (Cont.)
• Data can be saved for much longer periods than the
mandatory 12 hours on the PC’s hard disk (suitable for
owners use).
• Easy expansion of binary or analog inputs – built in Siemens
S7 PLC (14 binary inputs included as standard).
• Replay software module for both ship and office is included
as standard.
• The PMC is manufactured by Totem Plus eliminating the
need to rely on a third party and insures conforming to the
highest standards without compromising.
Replay and Analysis Software
• The replay software enables retrieval and display of all
recorded data.
• Current data (e.g. non-catastrophic data) can be saved in a
file and displayed on a dedicated PC onboard (or sent to the
head office).
• The stored data can be analyzed for incident investigation
and performance monitoring, for crew training and
analysis of ship’s operation.
• Data can be displayed on most major Electronic Chart
Display units (ECDIS).
Replay software – Main Screen
Enables the
selection of saved
data type to be
replayed
individually or
simultaneously
Replay of Recorded Radar Pictures
Radar pictures in
the saved file can be
advanced manually
or automatically
(fast forward)
Navigation information in a tabular form
Information in
the saved
navigation files is
presented in
tables
Replay of Recorded Audio
Saved Audio files can
be replayed using any
MP3 media player
program or the builtin Voice Replay
program
Multiple Information Screen
View Radar pictures,
listen to the Audio
channels and view
the navigational
information
simultaneously. The
recorded times are
automatically
synchronized
Totem Plus at a glance
Totem Plus goal is to create modern, reliable and affordable systems.
It has been developing ship automation and marine computerized applications
since 1994 and was one of the pioneers in integrating several systems into one
control system.
The Unique array of products developed by Totem Plus leads to easy
integration of several systems into one control system.
Totem Plus supports a global network of representatives and a considerable
installation base.
Quality assurance is under the assessment of DNV’s - ISO 9001.
Totem Plus Products at a glance
Additional products:
1. Engine Alarm, Monitoring and Control Systems.
(IMACS)
2. Loading programs (stress and stability) and
Emergency Response programs. (LoadMate)
3. Integrated Tank Gauging systems with its unique built
in loading program. (TankMate)
4. Dry Dock Organizer and automatic specification
report generator. (DDO)
Thank you
Please contact us with any technical or commercial questions at:
Totem Plus
29 Sokolov St.
POB 164 Herzliya 46100,
ISRAEL
Phone: + 972-9-9572458
Fax: + 972-9-9562018
www.TotemPlus.com
Rua Voluntários da Pátria 190/402
Rio de Janeiro – RJ
CEP 22270-010
Tel.: (21) 9982-6015
Fax: (21) 2535-8289
www.autosense.com.br