Philips Dynalite – Daniel Walker

Download Report

Transcript Philips Dynalite – Daniel Walker

Mastering the possibilities of
DALI with
Daniel Walker - Product Manager
[email protected]
August 2011
Agenda
•
•
•
•
•
•
•
•
Intro to the company
Why use lighting control
What a control system can do for you
What is DALI really
DALI system in detail
DALI organisation.
Philips Dynalite & DALI
DALI project 1 Shelly St
3
3
Philips Dynalite the company
• 1989 – 4 staff and a dream.
• Set up global HO in Sydney.
• Commitment to the future through continued
investment into R&D and manufacturing in
Australia.
• Over 17% of sales returns invested in R&D
to lead the controls market in system
features.
• Exporting globally to 46 countries.
• Export 70% of production from Australia.
• 2011 – 22 YEARS experience of building
lighting control solutions.
4
4
Dedicated to Research &
development
• Dedicated internal R&D.
• 60+ strong team working full time on
feature development and product
improvement
• Evolution approach to system design
• Using over rated components in all load
devices for building confidence within the
market place as a robust solution.
• All devices built to seamlessly complement
each other with out the need of network
patches.
• All Philips Dynalite devices engineered by
the same team to ensure compatibility
• All devices support Dynet communications
for full system transparency.
5
5
Committed to reduce product
carbon footprint
1989
Weight per channel 2.72kg
1996
Weight per channel 2.05kg
2006
Weight per channel 1.5kg
Philips Dynalite engineers are continually
looking at ways to reduce our own carbon footprint
via small wins in minimising our embodied Energy Consumption.
6
6
Committed to CO2 reductions
Being green system
Materials technology
RoHS compliant
Packaging
7
7
What it lighting control really?
Some people would say
8
8
Why use Control Technology
Typical two way switched conventional 4 circuit wiring with rotary dimmers
9
9
Why use Control Technology
Network control solution
10
10
Bring multiple lighting groups
together, creating a scene
Grand Hyatt - Dubai, UAE Ball room
11
11
Bring multiple lighting groups
together, creating a scene.
12
Cafe La Mode - Akropoleos, Cyprus
12
Where Dynalite can be found
Retail Scene
setting
Office automation
Energy management
Home automation
13
13
Index
Office buildings
Energy management
•
•
•
•
•
Daylight harvesting
Presence detection
Board room control
Energy monitoring
Allowing staff to
interaction with their
environment
14
Index
Retail Scene Setting
Painting with lighting
• Driving multiple lighting
groups together as one
• Automated scene control
• Direct LED dimming
• Red Green Blue light color
mixing
• Light patterns and chasers
15
Index
Home automation
& hotel room control
• Integrating different
systems together
• Easy to use and
intuitive control
points
• Creating a relaxed
home
16
Components of the
control system
17
17
User interfaces
• Wide range of interface panels to suit any
application.
•
•
•
•
18
Touch screens
Many finishes
Different styles
Integrated displays
18
Index
First to Market
Dual technology networked sensors
• Dynalite Sensors incorporate
•
•
•
•
PIR –Passive Infrared
UP – Ultrasonic
PE – Photoelectric Sensor
IR – Infrared Control
• Fully networked sensor.
• Capable of performing multiple
functions
• Provide Lux level settings for
daylight Harvesting mode
during day
19
Muscles of the system
DIN rail mounted
solution
20
Wall mounted
solution
20
The unseen advantage “Dynet”
• Dedicated lighting control protocol.
• Bring all the different components
together to form a system solution.
• Capable of system wide changes
with single network command.
• Uses industry standard RS485
• Published / Open protocol.
• All Philips devices use Dynet for
communication.
• Every device stores its own setting
making them all intelligent.
21
21
The total system solution
System Integration
n=15
Dynet
User Interfaces
n=326
Software &
Accessories
n=2
Load controllers
n=73
Any product can be used on any
project to match the load that
requires control.
22
22
Testament to reliability
Shangri-La Sydney
•
•
•
•
•
•
Formally the ANA hotel
First major project for Dynalite
Ball room, Restaurants & lobby
Full networked system installed
Project completed 19 years ago
Original dimmer units still operating
Confidential
23
23
Completed Hotel Projects
Taj Exotica Villa Development – Dubai
Hilton Hotel – Athens
Shangri-La – Sydney, Australia
24
Grand Hyatt Jin Mao – Shanghai
duoMo Hotel – Rimini, Italy
Intercontinental – Aqaba, Jordan
Swissotel – Moscow
Palazzo Versace
One & Only Kanuhura - Maldives
Burj Khalifa-120 floors
of control including
Armani Suites
24
Index
What is DALI ?
•A method of controlling individual light fittings
through network addressing
•Then linking the individual light fittings into
useful groups
25
Index
Types
of
DALI
•Three types of DALI
Area 1 lounge
Area 2 Kitchen
DALI Broadcast
Area 3 Dining
DALI Addressing
Area 1 lounge
12
9
Area 2 Kitchen
23
749
127
854
Area 3 Dining
6
345
48
568
65
117
DALI Multi Master
Area 1 lounge
4
35
48
Area 2 Kitchen
18
769
764
76
86
Area 3 Dining
65
624
91
42
345
43
1
26
Index
The raw DALI – Specifications
•
•
•
•
•
•
64 light fittings maximum per ‘universe’
16 Groups per universe
16 Scenes per universe
24V dc max 250mA Power Supply
2 core (240V rated) ‘data cable’
Data rate 1200 bps
(DALI control cable is NOT considered ELV due ballast electrical isolation)
27
Index
DALI
specs
•Digital Addressable Lighting Interface
•A protocol set out in the technical standard IEC 62386.
• DALI is a communication protocol dedicated for lighting
control
• DALI allows for communication individual light fixtures
• DALI is not owned by a single lamp or control system
manufacture
• DALI-AG is a working group set up by leading
manufacturers and institutions in the field of digital
lamp/luminaire control to promote DALI technology and
applications.
• http://www.dali-ag.org
28
Index
DALI – Power Consumption
• DALI ballasts/transformers consume
power to operate even when their fitting is
off.
• Approx. 0.5 to 2 watt per ballast
(up to 2% of operation power per luminaire)
• This power consumption never stops even
when the lights are off.
29
Index
Who represents DALI
•Current members of DALI-AG
ABB - ALTENBURGER - B.E.G. - BAG - BTICINO - CABA - CEAG - CP
ELECTRONICS LTD - DELMATIC - DIAL - DISTECH CONTROLS SAS DYNALITE - ECKERLE - ELDOLED - ELTAM - ERC - ERCO - ETAPExcellum - EUTRAC - FIFTH - GERARD - GEWISS - GITRONICA - HÜCO HADLER - HARVARD ENGINEERING PLC - HELVAR - HERBERT
WALDMANN GMBH & CO KG - HESCH INDUSTRIE-ELEKTRONIK GMBH INFRANET - INSTA - KATHREIN Austria - LEGRAND GROUP - LIGHTOLIER LUTRON - MACKWELL - ME - MERTEN - NIKO - NOVAR ED&S Limited OSRAM - PHILIPS - RENESAS ELECTRONICS EUROPE GMBH - SANDER SCEMTEC - SCHNEIDER ELECTRIC - SIMMTRONIC - SITECO
BELEUCHTUNGSTECHNIK - SPITTLER - STEINEL PROFESSIONAL - TCI TRIDONIC - UNIVERSAL - VOSSLOH - WAGO - XAL - ZUMTOBEL
30
Index
Who owns DALI
The currently DALI-AG Board of Directors
Birkhofer, Hans-Peter (OSRAM) - Chairman
Montijn, Richard (Philips Lighting)
Van der Kolk, Peter (Helvar)
Mathis, Ulrich (Tridonic)
Von der Brelie, Jens (Erco)
Managing Director
Dr. Jürgen Waldorf (ZVEI Luminaires Div.)
31
Index
DALI & Philips Dynalite
• DALI enumeration and group commissioning performed by Philips
Dynalite load controller
• One commissioning tool (Envision) for DALI addressing, DALI
grouping, load controller, user interfaces & integration devices.
• Built in features
•
•
•
•
•
DALI power supply
DALI transmitter
DALI scene controllers
Integrated power relays per universe
240V supply to the unit so no external power transformer is needed.
• 240V isolation provided
• Built in test sequence to allow contractor fault find wiring or ballasts
issues prior to commencement of commissioning.
• No system network clock or network burden - NO SINGLE POINT
OF FAILURE
32
Index
Three Philips Dynalite DALI solutions
•
•
DALI broadcasting control, All lamps controlled
together
12 independently controlled outputs
•
•
•
Full DALI, allows for full addressing and grouping
3 DALI universes (192 DALI addresses)
Built in power relays
DDBC1200
DDBC320-DALI
•
•
•
DDBC120-DALI
•
DALI Multi Master, allows for full addressing,
grouping and control over use interfaces on the
DALI network
1 DALI universes (64 DALI addresses)
DALI user interface management allowing for
sensors and dry contact interfaces on DALI network.
Built in power relays
33
DALI broadcasting
•Every area can be dimmed
•Each lighting group requires
its own individual cable run.
•All user interfaces require
separate network run.
Total of 8 different cable runs are required for system.
34
DALI Addressing
•Every area can be dimmed
•DALI can address each
group of lights individually.
•All user interfaces require
separate network run.
Total of 2 different cable runs are required for system.
35
DALI-Multi Master
•Every area can be dimmed
•DALI can address each
group of lights individually.
•All user interfaces use same
network as the light fittings
Only one cable run required for the entier system.
36
1 Shelly St
•
•
•
•
•
•
•
•
•
96 x DALI universes
44 x Leading edge channels
684 x Switching channels
336 x DSI channels
168 x LED channels
91 x Touch screens
364 x Motion / Lux sensors
1 x BACnet
1 x Dynalite computer head
end software
37
37