Portfolio InCCA - Key Messages
Positioning - Target Customer
Throughput - Comparison
Menu
Portfolio
®
Excellent relation between cost / benefit
InCCA joined technology, functionality and productivity in only one equipment.
Autoanalyzer perform clinical chemistry and immunochemistry assays, and abuse drugs
•Up to 120 tests/hour
•220 μl – 400 μl reagent volume/test
•Reagents cooling optional
•Parameters for VETERINARIAN area
•Continuous input samples and reagents during running
•Impact and level sensors probe
•Removable reaction tray
•Auto re-run with auto-dilution
•Statistics of controls, calibrators and patients
•Low reagent and water consumption
•Reagent inventory check
•ISE optional
• Up to 360 tests/hour
• 220 µl – 400 µl reagent volume/test
• Reagents cooling
• Cuvettes washer
• Continuous input samples and reagent during running
• Auto re-run with auto-dilution
• Interferences management
• Statistics of controls calibrators and patients
• Impact and level sensors probe
• Low reagent and water consumption
• Reagent inventory check
• Patients advantage search
• Barcode for sample tubes (optional)
• Up to 450 tests/hour W/ISE
• 220µl – 400µl reagent volume/test
• Reagents cooling system
• Cuvettes chemical washer
• Continuous input samples and reagent during running
• Auto re-run with auto-dilution
• Statistics of controls, calibrators and patients
• Impact and level sensors probe
• Interferences management
• Patients advanced search
• Barcode for sample tubes (optional)
• Low reagent and water consumption
• Reagent inventory check
• ISE optional
• LIS
Key Messages InCCA
COMPACT
VERSATIL
RELIABLE
PRODUCTIVE
INTELLIGENT
Versatil OEM options
Productivity, Economy, Versatility and Reliability Results
- Primary tubes
and sample cups
- Probe level and
impact sensors
- Internal and
external washing
probe
- Automatic
washing system
- 100 reusable
cuvettes
Productivity, Economy, Versatility and Reliability Results
Sample and Reagent Tray
•Open System
•60 reagent positions
Reagent tray cooling system
•With independent key prolongs the life of the equipment
•Continuous loading of samples: 60 physical positions
•Barcode for sample tubes (optional)
•Low reagent consumption
•Pre-samples and reagents preheating
•Interference Management
•No limit for positions STAT
Easy to use
•Bar Code Identification
•Ready to use in ten minutes
•Automatic Washing, minimal water consumption
•Friendly software
•Simplified maintenance
Maintenance and Consumables
Reduced Maintenance:
Daily Routine: Cuvette and probe wash
Weekly Routine: Photometer and Cuvettes calibration
Consumables:
Cuvettes: long life PMMA cuvettes
Tubing: every 6 months
Lamp: every 3 years
Minimum water consumption and washing solution: 4 ml per test
Positioning
TEST HOUR
300- 450
240-320
100 -400 pat/day
50 -300 pat/day
80-120
10 -100 pat/day
LOW
MEDIUM
HIGH
VOLUME
Laboratory with growing demand
Positioning
InCCA MAX
InCCA bit
Low volume
Medium volume
Customer Target
60 - 600 test per day
300 -1800 test per day
600 -2400 test per day
InCCA® Systems installed
Installed base >1000 units
Distribution worldwide
Portfolio
Compact
Automatization
Reliables Results
We take care of
laboratory growing
Productivity
Minimal Cost
Standardization in