DVP800, 1200, 1600

Download Report

Transcript DVP800, 1200, 1600

DVP800, 1200, 1600
Instruktionsbok
© DeLaval 2013.
2013-09-23, Version 2
92746731
Bruksanvisning i original
DVP800, 1200, 1600
Innehållsförteckning
Säkerhetsföreskrifter.......................................................................................................................... 5
n Vakuumpump DVP800, 1200, 1600
1
Allmänt.............................................................................................................................. 5
Allmän beskrivning............................................................................................................................. 8
n Vakuumpump DVP800, 1200, 1600
1
2
3
4
5
6
7
8
9
10
Allmänt.............................................................................................................................. 8
Pump................................................................................................................................. 9
Koppling.......................................................................................................................... 10
Motor............................................................................................................................... 10
Ljuddämpare/oljeåtervinnare........................................................................................... 10
Oljebehållare................................................................................................................... 11
Backventil........................................................................................................................ 11
Cyklonvattenlåskärl......................................................................................................... 12
Säkerhetsventil................................................................................................................ 13
Dubbel installationssats för 2 x DVP 800........................................................................ 13
Produktdata........................................................................................................................................ 14
n DeLaval vakuumpump DVP800, DVP1200, DVP1600
1
2
3
4
Artikelnummer.................................................................................................................
1.1 DVP 800..........................................................................................................
1.2 DVP 1200........................................................................................................
1.3 DVP 1600........................................................................................................
Beskrivning......................................................................................................................
Tekniska data..................................................................................................................
3.1 DVP 800..........................................................................................................
3.2 DVP 1200........................................................................................................
3.3 DVP 1600........................................................................................................
Mått.................................................................................................................................
14
14
14
14
15
16
16
17
18
19
Handhavande..................................................................................................................................... 20
n Vakuumpump DVP800, 1200, 1600
1
2
Före mjölkning................................................................................................................. 20
Efter mjölkningen............................................................................................................ 20
Underhåll genom operatör................................................................................................................ 22
n DeLaval vakuumpump DVP800, DVP1200, DVP1600
1
2
Risker vid underhåll......................................................................................................... 22
Serviceuppgifter.............................................................................................................. 22
Felsökning.......................................................................................................................................... 27
n Vakuumpump DVP800, 1200, 1600
1
2
DVP800, 1200, 1600....................................................................................................... 27
DVP vakuumsystem........................................................................................................ 28
© DeLaval 2013.
2013-09-23, Version 2
3 (30)
92746731
DVP800, 1200, 1600
Innehållsförteckning
© DeLaval 2013.
2013-09-23, Version 2
4 (30)
92746731
DVP800, 1200, 1600
Säkerhetsföreskrifter
Säkerhetsföreskrifter
Vakuumpump DVP800, 1200,
1600
1 Allmänt
Pumpen måste installeras av auktoriserad
DeLaval-personal. Den elektriska installationen
måste utföras av en auktoriserad elektriker. Se
till att installationen utförs så att följande säkerhetskrav uppfylls:
Det rum där vakuumpumpen installeras
n måste vara konstruerat av brandsäkra tak-,
vägg- och golvmaterial.
n får inte användas för att lagra lättantändliga
ämnen.
n måste vara avskilt från utrymmen där människor normalt arbetar. Pumpen avger ljud.
n måste vara tillräckligt ventilerat. Självantändning och tekniska problem måste undvikas.
Vakuumpumpen måste:
n måste installeras på ett fast underlag, helst
av betong, för att minimera spridningen av
vibrationer och buller.
n måste vara ordentligt fastmonterad.
n får inte användas om inte alla skyddsplåtar
sitter på plats.
n får bara användas för utpumpning av luft från
mjölkningsmaskinen till en vakuumnivå som
inte överskrider 60 kPa.
n får inte spolas med vatten eller andra vätskor.
Vakuumpumpens utlopp:
n måste utmynna utomhus.
n måste vara placerat på ett säkert avstånd
från brännbara ämnen.
n måste ha installerats så att man inte riskerar
att bränna sig på heta delar.
n måste vara placerat så att man undviker störande ljud från pumpen.
© DeLaval 2013.
2013-09-23, Version 2
5 (30)
92746731
DVP800, 1200, 1600
Säkerhetsföreskrifter
Varning!
Du får inte starta eller köra utrustningen om inte alla skärmar, lock
och skydd sitter på plats, såvida inte
andra instruktioner uttryckligen kräver detta.
Se upp!
Koppla från strömförsörjningen
innan du börjar reparera. Utrustningen kan fjärrstartas.
Varning!
Koppla alltid bort pumpen från vakuumledningen innan du börjar reparera, när parallella pumpar har
installerats. Pumprotorn kan roteras
genom vakuum som genereras av
en parallell pump.
Varning!
Om vakuumpumpen körs med för
högt mottryck kan den överhettas
med risk för brand eller annan skada
på vakuumpumpen.
Varning!
Kör aldrig pumpen med ett blockerat
utlopp. Detta kan leda till överhettning och risk för brand och andra
skador.
Varning!
Om utrustningen inte har fästs
ordentligt kan den flyttas och dra
loss elkablarna.Detta kan leda till
personskada och risk för brand.
© DeLaval 2013.
2013-09-23, Version 2
6 (30)
92746731
DVP800, 1200, 1600
Säkerhetsföreskrifter
Förbjudet!
Kliv inte på motor, pump eller ljuddämpare. Delarna kan vara hala,
med risk för att man halkar och skadar sig. Delarna kan deformeras och
skadas.
Se upp!
Följ serviceanvisningarna. Om pumpens olja tar slut, riskerar pumpen att
överhettas, med brandrisk och
andra skador som följd.
Varning!
Enheten avger ett störande buller
med en ljudnivå på 85 dBA eller mer,
vilket är skadligt vid långvarig exponering och/eller på kort avstånd.
Obligatoriskt!
Använd alltid lämpliga hörselskydd
när du arbetar i ett rum där det finns
ett aggregat som är igång.
Varning!
De angivna områdena blir heta
under drift och kan orsaka brännskador vid kontakt (90-150 °C/200-300
°F).
Markerade områden:
n Pumpkapsling
n Utblåsningsledning
n Ljuddämpare
© DeLaval 2013.
2013-09-23, Version 2
7 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
Allmän beskrivning
Vakuumpump DVP800, 1200,
1600
1 Allmänt
Vakuumpumpen består av följande delar:
Den nominella vakuumpumpskapaciteten
uttrycks i antal liter luft per minut, uppmätt vid:
n vakuum på 50 kPA (14,8'' Hg),
n omgivande temperatur på 20 °C (68 °F),
n omgivande atmosfärstryck på 1000 mbar/
100 kPa (14,7 PSIA).
© DeLaval 2013.
2013-09-23, Version 2
8 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
2 Pump
212485
Vakuumpumpen är en luftkyld rotationspump av
excentertyp. Den drivs av en elektrisk motor via
en koppling. Pumpens drivaxel är tätad med en
flänsad tätningsring.
Pumpen smörjs med olja genom smörjnipplar.
Oljan sugs genom nipplarna in i lagren och vidare
in bland pumpens rörliga delar.
211341
Lagren är specialbehandlade, så att de ska tåla
hettan från pumpen.
© DeLaval 2013.
2013-09-23, Version 2
9 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
3 Koppling
211343
Kopplingen överför kraften från motorn till pumpen och reducerar överföringen av axiella och
radiella krafter mellan motorn och pumpen.
4 Motor
211344
Motorn är en flänsmonterad elektrisk motor med
särskild lagerlåsning.
5 Ljuddämpare/oljeåtervinnare
211345
Ljuddämparen/oljeåtervinnaren styr frånluften
genom ett antal skärmade kamrar inuti ett stålhölje, vilket minskar utblåsningens ljudnivå. Ljuddämparen/oljeåtervinnaren separerar också
smörjolja från frånluften.
© DeLaval 2013.
2013-09-23, Version 2
10 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
6 Oljebehållare
211346
Lubrikatorn, av kapillärtyp, förser pumpen med
ett konstants oljeflöde.
7 Backventil
211347
Varje pump är utrustad med en backventil som
ska installeras i inloppsböjen, ovanför vakuumpumpen. Denna konstruktion begränsar motrotationen när pumpmotorn stängs av.
© DeLaval 2013.
2013-09-23, Version 2
11 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
8 Cyklonvattenlåskärl
Cyklonvattenlåskärlet separerar vätskor och
fasta partiklar från luftströmmen, och förhindrar
på så vis att pumpen tar skada.
Vattenlåset är försett med tappventil längst ned.
Ventilen stängs automatiskt när det är vakuum i
vattenlåset. När vakuumet upphör öppnas ventilen och vätska och skräp som trängt in i vattenlåset töms ut.
Vattenlåset är utrustat med en flottörventil som
stänger vakuumledningen till pumpen om vattenlåset fylls med vätska.
Anslutningar:
CIV 75
n 75 mm anslutningar för inlopp och utlopp.
n 50 mm dräneringsrör
CIV 110
211350
n 110 mm anslutningar för inlopp och utlopp.
n 50 mm dräneringsrör
© DeLaval 2013.
2013-09-23, Version 2
12 (30)
92746731
DVP800, 1200, 1600
Allmän beskrivning
9 Säkerhetsventil
Säkerhetsventilen, SV, öppnas när vakuumnivån
överskrider 60 kPa. I öppet läge släpper den in
luft och avger ett starkt visslande ljud.
Ventilen kan inte återställas om inte vakuumpumpen stängas av och vakuumet försvinner ur
systemet. Manuell återställning är nödvändig.
211358
n Säkerhetsventilen måste monteras mellan
vattenlåskärlet och vakuumpumpen.
n Man bör helst installera säkerhetsventilen så
nära vattenlåskärlet som möjligt.
n Säkerhetsventilen ska monteras vertikalt.
10 Dubbel installationssats för 2 x
DVP 800
211359
184001445
© DeLaval 2013.
2013-09-23, Version 2
13 (30)
92746731
DVP800, 1200, 1600
Produktdata
Produktdata
DeLaval vakuumpump DVP800,
DVP1200, DVP1600
1 Artikelnummer
1.1 DVP 800
Artikelnummer
Beskrivning
90819986
3 x 200 V (50 Hz)
90819987
3 x 200 V (60 Hz)
90819980
3 x 230/400 V (50 Hz)
90819981
3 x 230/400 V (60 Hz)
90819982
3 x 460 V (60 Hz)
1.2 DVP 1200
Artikelnummer
Beskrivning
90820086
3 x 200 V (50 Hz)
90820087
3 x 200 V (60 Hz)
90820080
3 x 230/400 V (50 Hz)
90820081
3 x 400 V (60 Hz)
90820082
3 x 460 V (60 Hz)
1.3 DVP 1600
Artikelnummer
Beskrivning
90820186
3 x 200 V (50 Hz)
90820183
1 x 230 V (60 Hz)
90820188
3 x 230/400 V (50 Hz)
90820180
3 x 400/690 V (50 Hz)
90820181
3 x 400 V (60 Hz)
90820182
3 x 460 V (60 Hz)
© DeLaval 2013.
2013-09-23, Version 2
14 (30)
92746731
DVP800, 1200, 1600
Produktdata
2 Beskrivning
(11)
(7)
Vakuumpumpsystemet består av följande:
(8)
(4)
(10)
(9)
(5)
(3)
(1)
(1) Pump (en av tre olika storlekar)
(2) Koppling
(3) Motor
(4) Ljuddämpare (minskar utloppsljud)
(5) Backventil (stoppar rotation)
(6) Oljebehållare (smörjer vakuumpumpen)
(7) Cyklonavskiljare (effektiv avskiljning)
(8) Rör och böjar
(9) T för kapacitetstest
(10) Kopplingsnippel för maskintest
(11) Säkerhetsventil
(6)
212667
(2)
n
n
n
n
n
n
n
n
n
n
n
© DeLaval 2013.
2013-09-23, Version 2
15 (30)
92746731
DVP800, 1200, 1600
Produktdata
3 Tekniska data
3.1 DVP 800
3 x 200 V
(50 Hz)
Pumpkapacitet vid 50 Hz / 800 l/min
60 Hz
(28,2 CFM)
3 x 200 V
(60 Hz)
3 x 230/400 V 3 x 230/400 V 3 x 460 V
(50 Hz)
(60 Hz)
(60 Hz)
900 l/min
(32 CFM)
800 l/min
(28,2 CFM)
900 l/min
(32 CFM)
900 l/min
(32 CFM)
Pump/motor vid 50 Hz /
60 Hz
1425 VARV/ 1725 VARV/ 1425 VARV/ 1725 VARV/ 1725 VARV/
MIN
MIN
MIN
MIN
MIN
Elmotor (effekt)
2,2 kW
Elmotor (spänning)
200 VAC ±10 200 VAC ±10 230/400 VAC 230/400 VAC 460 VAC ±10
%
%
±10 %
±10 %
%
3 kW
2,2 kW
3 kW
5 HP
Elmotor (packboxstorlek) ISO 20
ISO 20
ISO 20
ISO 20
2 x ISO 20
Vakuumanslutning
75 mm
75 mm
75 mm
75 mm
75 mm
Utloppsanslutning
50 mm
50 mm
50 mm
50 mm
50 mm
Max. mottryck
5 kPa
5 kPa
5 kPa
5 kPa
5 kPa
Min. driftsvakuum
20 kPa
20 kPa
20 kPa
20 kPa
20 kPa
Max. driftsvakuum
55 kPa
55 kPa
55 kPa
55 kPa
55 kPa
Omgivningstemperatur
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
* Bullernivå vid pumpenhet (vid 50 kPa)
–
–
76 dB(A)
78 dB(A)
–
* Bullernivå vid utblås–
ningsledning (vid 50 kPa)
–
69 dB(A)
68 dB(A)
–
* Bullernivå vid pumpenhet (vid 42 kPa)
–
–
71 dB(A)
73 dB(A)
–
* Bullernivå vid utblås–
ningsledning (vid 42 kPa)
–
69 dB(A)
68 dB(A)
–
Vikt (med motor och ljud- 69 kg
dämpare på fot)
69 kg
69 kg
–
–
* Bullernivån kan variera i hög grad beroende på installationsanläggning.
© DeLaval 2013.
2013-09-23, Version 2
16 (30)
92746731
DVP800, 1200, 1600
Produktdata
3.2 DVP 1200
3 x 200 V
(50 Hz)
Pumpkapacitet vid 50 Hz / 1200 l/min
60 Hz
(42,3 CFM)
3 x 200 V
(60 Hz)
3 x 230/400 V 3 x 400 V
(50 Hz)
(60 Hz)
3 x 460 V
(60 Hz)
1400 l/min
(42 CFM)
1200 l/min
(28,2 CFM)
1400 l/min
(42 CFM)
1400 l/min
(42 CFM)
Pump/motor vid 50 Hz /
60 Hz
1425 VARV/ 1725 VARV/ 1425 VARV/ 1725 VARV/ 1725 VARV/
MIN
MIN
MIN
MIN
MIN
Elmotor (effekt)
3 kW
Elmotor (spänning)
200 VAC ±10 200 VAC ±10 230/400 VAC 400 VAC ±10 460 VAC ±10
%
%
±10 %
%
%
4 kW
3 kW
4 kW
5 HP
Elmotor (packboxstorlek) ISO 20
ISO 20
2 x ISO 20
2 x ISO 20
2 x ISO 20
Vakuumanslutning
75 mm
75 mm
75 mm
75 mm
75 mm
Utloppsanslutning
75 mm
75 mm
50 mm
75 mm
75 mm
Max. mottryck
5 kPa
5 kPa
5 kPa
5 kPa
5 kPa
Min. driftsvakuum
20 kPa
20 kPa
20 kPa
20 kPa
20 kPa
Max. driftsvakuum
55 kPa
55 kPa
55 kPa
55 kPa
55 kPa
Omgivningstemperatur
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
* Bullernivå vid pumpenhet (vid 50 kPa)
–
–
70 dB(A)
73 dB(A)
–
* Bullernivå vid utblås–
ningsledning (vid 50 kPa)
–
63 dB(A)
64 dB(A)
–
* Bullernivå vid pumpenhet (vid 42 kPa)
–
–
72 dB(A)
75 dB(A)
–
* Bullernivå vid utblås–
ningsledning (vid 42 kPa)
–
65 dB(A)
67 dB(A)
–
Vikt (med motor och ljud- 110 kg
dämpare på fot)
110 kg
106 kg
110 kg
110 kg
* Bullernivån kan variera i hög grad beroende på installationsanläggning.
© DeLaval 2013.
2013-09-23, Version 2
17 (30)
92746731
DVP800, 1200, 1600
Produktdata
3.3 DVP 1600
3 x 200 V
(50 Hz)
Pumpkapacitet vid
50 Hz / 60 Hz
1 x 230 V
(60 Hz)
1600 l/min 1900 l/min
(56,5 CFM) (67 CFM)
3 x 230/400 3 x 400 V
V (50 Hz) (60 Hz)
3 x 460 V
(60 Hz)
3 x 400/690
V (50 Hz)
1600 l/min 1900 l/min
(56,5 CFM) (67 CFM)
1900 l/min
(67 CFM)
1600 l/min
(56,5 CFM)
Pump/motor vid 50 Hz / 1425
1725
1425
1725
1725
1425
60 Hz
VARV/MIN VARV/MIN VARV/MIN VARV/MIN VARV/MIN VARV/MIN
Elmotor (effekt)
4 kW
7,5 HP
4 kW
5,5 kW
7,5 HP
4 kW
Elmotor (spänning)
200 VAC
±5 %
230 VAC
±5 %
400 VAC
±10 %
400 VAC
±10 %
460 VAC
±10 %
400 VAC
±10 %
Elmotor (packboxstor- ISO 20
lek)
ISO 25
ISO 20
ISO 20
ISO 25
2 x ISO 20
Vakuumanslutning
75 mm
75 mm
75 mm
75 mm
75 mm
75 mm
Utloppsanslutning
75 mm
75 mm
75 mm
75 mm
75 mm
75 mm
Max. mottryck
5 kPa
5 kPa
5 kPa
5 kPa
5 kPa
5 kPa
Min. driftsvakuum
20 kPa
20 kPa
20 kPa
20 kPa
20 kPa
20 kPa
Max. driftsvakuum
55 kPa
50 kPa
50 kPa
50 kPa
50 kPa
55 kPa
Omgivningstemperatur
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
0 - 45°C
* Bullernivå vid pumpenhet (vid 50 kPa)
–
–
–
75 dB(A)
–
71 dB(A)
* Bullernivå vid utblås- –
ningsledning (vid
50 kPa)
–
–
66 dB(A)
–
64 dB(A)
* Bullernivå vid pumpenhet (vid 42 kPa)
–
–
–
75 dB(A)
–
74 dB(A)
* Bullernivå vid utblås- –
ningsledning (vid
42 kPa)
–
–
72 dB(A)
–
68 dB(A)
Vikt (med motor och
ljuddämpare på fot)
–
–
120 kg
–
117 kg
–
* Bullernivån kan variera i hög grad beroende på installationsanläggning.
© DeLaval 2013.
2013-09-23, Version 2
18 (30)
92746731
DVP800, 1200, 1600
Produktdata
212526
4 Mått
© DeLaval 2013.
2013-09-23, Version 2
19 (30)
92746731
DVP800, 1200, 1600
Handhavande
Handhavande
Vakuumpump DVP800, 1200,
1600
1 Före mjölkning
Kontrollera vakuumpumpen och vakuumsystemet enligt följande:
n Se till att vakuumregulatorn fungerar genom
att kontrollera att den tar in luft.
n Kontrollera att oljan flyter från lubrikatorn till
vakuumpumpen.
n Kontrollera på vakuummätaren att vakuumnivån är korrekt.
n Kontrollera (genom att lyssna) om det finns
några luftläckor i vakuumsystemet.
Varning!
Kör aldrig pumpen med ett blockerat
utlopp. Detta kan leda till överhettning och risk för brand och andra
skador.
2 Efter mjölkningen
Kontrollera vakuumpumpen och vakuumsystemet enligt följande:
n Kontrollera vattenlåsets dränering. Om det
har kommit in mjölk i vattenlåset, måste du
finna och åtgärda orsaken.
n Kontrollera om mjölk har kommit in i vakuumledningen. Om så är fallet måste du finna
och åtgärda orsaken. Det kan bli nödvändigt
att rengöra hela vakuumsystemet.
© DeLaval 2013.
2013-09-23, Version 2
20 (30)
92746731
DVP800, 1200, 1600
Handhavande
n Se till att pumpen inte roterar i motsatt riktning efter det att motorn har varit stillastående. Om så är fallet beror det på att
backventilen inte fungerar som den ska. Låt
en auktoriserad DeLaval-servicetekniker
åtgärda felet.
© DeLaval 2013.
2013-09-23, Version 2
21 (30)
92746731
DVP800, 1200, 1600
Underhåll genom operatör
Underhåll genom operatör
DeLaval vakuumpump DVP800,
DVP1200, DVP1600
1 Risker vid underhåll
Fara!
Risk för elektrisk stöt!
Koppla alltid ifrån huvudströmmen
och om sådan finns låser du huvudströmbrytaren i avstängt läge, innan
du utför några installationer, inspektioner, justeringar, underhåll eller
service på utrustningen. Vänta tills
alla rörliga delar har stannat och
kondensatorerna är urladdade.
B
Varning!
De angivna områdena blir heta
under drift och kan orsaka brännskador vid kontakt (90-150 °C/200-300
°F).
C
Rör inte följande delar av vakuumpumpen, eftersom de fortfarande kan vara heta:
234118
A
n Pumpkapsling (A)
n Utblåsningsledning (B)
n Ljuddämpare (C)
Bild 1: Heta delar på vakuumpumpen.
2 Serviceuppgifter
Nr
Underhållsuppgift för operatörer
Frekvens
Max. intervall
1
Fylla oljebehållaren med olja
-
Weekly
2
Tömma vakuumpumpens oljereservoar
-
Monthly
© DeLaval 2013.
2013-09-23, Version 2
22 (30)
Reservdelar
eller satser
92746731
DVP800, 1200, 1600
Underhåll genom operatör
Frekvens
-
Max. intervall
Weekly
Uppskattad tid
-
Typ av service:
Påfyllning
© DeLaval 2013.
2013-09-23, Version 2
Nr 1 Fylla oljebehållaren med olja
23 (30)
92746731
DVP800, 1200, 1600
Underhåll genom operatör
Utför denna serviceåtgärd när systemet är inaktivt.
210392
1. Koppla bort strömmen till vakuumpumparna i vakuumsystemet.
Bild 2: Vakuumpumpens oljebehållare.
2. Verifiera att det finns olja i oljebehållaren
och att rören från oljebehållaren inte är
fyllda med olja.
Obs! Kontakta servicetekniker om rören är
fyllda med olja. Oljetillförseln är feljusterad
eller oljebehållaren är sönder.
3. Inspektera skicket på rören från oljebehållaren till vakuumpumphuset.
Obs! Kontakta servicetekniker om det finns
sprickor eller skador i rören.
© DeLaval 2013.
2013-09-23, Version 2
24 (30)
92746731
DVP800, 1200, 1600
Underhåll genom operatör
4. Fäll ned påfyllningsflaskan för att ta loss
den från oljebehållaren.
234119
5. Skruva bort locket.
Bild 3: Nedfällning av oljebehållarens påfyllningsflaska.
6. Fyll oljebehållaren med olja.
Obs! Vi rekommenderar DeLavals universalvakuumpumpolja.
234155
7. Skruva tillbaka locket på flaskan.
Bild 4: Påfyllning av olja i påfyllningsflaskan.
8. För in påfyllningsflaskans gångjärnsbult
under tungorna på kanten av oljebehållarhuset.
9. Fäll snabbt upp påfyllningsflaskan tills den
trycks på plats.
234123
10.Anslut strömförsörjningen till vakuumpumpen.
Bild 5: Uppfällning av påfyllningsflaskan.
© DeLaval 2013.
2013-09-23, Version 2
25 (30)
92746731
DVP800, 1200, 1600
Underhåll genom operatör
Frekvens
-
Max. intervall
Monthly
Uppskattad tid
-
Typ av service:
Justera
Nr 2 Tömma vakuumpumpens oljereservoar
Utför denna serviceåtgärd när systemet är inaktivt.
1. Koppla bort strömmen till vakuumpumparna i vakuumsystemet.
2. Skruva loss ljuddämparens rör från oljereservoaren.
210393
MAX
Bild 6: Tömning av vakuumpumpens oljereservoar.
3. Töm oljan i oljereservoaren.
4. Skruva tillbaka ljuddämparens rör på oljereservoaren.
5. Anslut strömförsörjningen till vakuumpumpen.
© DeLaval 2013.
2013-09-23, Version 2
26 (30)
92746731
DVP800, 1200, 1600
Felsökning
Felsökning
Vakuumpump DVP800, 1200,
1600
1 DVP800, 1200, 1600
Fara!
Koppla alltid ifrån huvudströmmen
och om sådan finns låser du huvudströmbrytaren i avstängt läge, innan
du utför några installationer, inspektioner, justeringar, underhåll eller
service på utrustningen.
Nr
Symtom
Orsak
Åtgärd
1
Pumpen roterar för långsamt.
Motorns varvtal är för lågt.
Kontrollera nätspänningen.
2
Pumpens kapacitet verkar
ha sjunkit.
2a. Avskiljarens tömningsventil Kontrollera, rengör eller byt ut
stängs inte.
tömningsventilen.
2b. Oljeflödet till pumpen
Se punkt 3 nedan.
räcker inte för tillräcklig tätning.
2c. Skovlarna är slitna.
3
Lite olja eller ingen alls flyter 3a. Nippeln eller kanalen har
genom lubrikatorns kanaler. täppts igen.
Låt en servicetekniker kontrollera pumpens kapacitet, och
genomför vid behov en 8 000timmarsservice.
Rengör med lacknafta. Blås
igenom kanalerna och nipplarna.
3b. Luftläckor mellan nipplarna Byt ut kanalerna.
och kanalerna.
3c. Flödet från oljebehållaren
har inte justerats ordentligt.
Justera reglageskruven på
lubrikatorn.
3d. Luftläckor vid slutet av
axeln.
Kontrollera axelpackningen.
Låt servicetekniker byta axelpackning.
3e. Pumpen är inte tät.
Låt servicetekniker kontrollera
alla packningar och tätningar.
4
Olja verkar flyta från en nip- Skovlarna är slitna.
pel tillbaka till lubrikatorn.
Låt servicetekniker genomföra
8 000-timmarsservice.
5
Vakuumpumpen roterar bak- Backventilen stängs inte.
länges när motorn stängs av.
Rengör eller byt backventil.
© DeLaval 2013.
2013-09-23, Version 2
27 (30)
92746731
DVP800, 1200, 1600
Felsökning
2 DVP vakuumsystem
Nr
Symtom
Orsak
1
Vakuummätaren visar för
hög vakuumnivå.
1a. Signalslangen mellan sen- Justera slangen till rätt läge.
sorn VRS och regulatorn VRM,
eller mellan regulatorn MVR
och vakuumledningen, är
blockerad eller lös.
2
Vakuummätaren anger för
låg vakuumnivå.
Åtgärd
1b. Vakuumregulatorn är
klämd, igensatt eller deformerad.
Kontrollera med hörseln att luft
sugs in i regulatorn. Rengör
eller byt ut regulatorn.
1c. Vakuummätaren fungerar
inte.
Kontrollera och byt ut mätaren
om så behövs.
2a. Avskiljarens tömningsventil Kontrollera avskiljarens tömeller avskiljaren läcker.
ningsventil och avskiljaren.
Rengör eller byt ventil. Byt
packning.
2b. Luft läcker genom röranslutningarna eller genom tvåeller trevägsventiler.
Kontrollera och dra åt anslutningar och ventiler.
2c. Säkerhetsventilen har löst
ut till öppet läge.
Se information om säkerhetsventil SV i instruktionerna.
Se 1a, 1b, 1c, 3a
2d. Smuts eller främmande
Rengör vakuumledningen. Se
partiklar har kommit in i vakuu- information om vakuumsystemledningen.
met i servicekapitlet.
3
4
Vakuummätaren visar inte
något vakuum.
Vakuumnivån varierar.
© DeLaval 2013.
2013-09-23, Version 2
2e. Fel i vakuumpump.
Se information om vakuumpump i felsökningstabellen.
2f. Vakuummätaren fungerar
inte.
Kontrollera och byt ut mätaren
om så behövs.
3a. Avskiljarens flottörventil är Stoppa vakuumpumpen och
stängd. Avskiljaren är fylld med töm avskiljaren. Kontrollera att
vätska.
tömningsventilen öppnas när
rörledningen inte är under
vakuum. Rengör flottörventilen.
3b. Det finns stora läckor i
systemet.
Åtgärda läckorna.
3c. Vakuummätaren fungerar
inte.
Kontrollera och byt ut mätaren
om så behövs.
Vakuumregulatorn fungerar
inte korrekt.
Se information om vakuumregulatorn i instruktionerna.
28 (30)
92746731
is a registered trademark of Tetra Laval Holdings & Finance S. A. and DeLaval is a registered trade/service
mark of DeLaval Holding AB.
DeLaval
Box 39
SE-147 21 Tumba
SWEDEN
www.delaval.com