Transcript Quality Control for Tea Beverage
Quality Control for PH of Tea Final Presentation YU Jiayi, CUI Liwen, CHEN Rui, GUO Dingcheng, CAO Qing 1
Project Overview Suggestions
PH
value Control Define DOE Improve Analyze Measure Gage R&R Off-line Experiments 2
Project Overview Control
Define
Improve Measure Analyze 3
Define (1/3) • Study Problem – As the PH value of tea beverage is an important quality index, we would like to study the factors that would affect the PH value through off-line experiments . – We expect to obtain the the recommended values related influence factors to obtain the recommended PH value, thus production of tea beverage.
guiding the real of 4
Define (2/3) • • Response (
y
) – PH value of tea beverage • Green Tea: PH value of 6.2 recommended Factors (
x
) – Temperature – Time – Percentage of Tea – Container (stainless steel, glass, ceramic, etc.) 5
Define (3/3) • Methodology: Design of Experiment – Off-line experiments – Gage R&R study – GLM • Identify significant factors • Specify relationships between
x
and
y
6
Project Overview Control Define Improve Analyze
Measure
7
Measurement Instruments Electronic PH-meter Electronic Scale Temperature-control Pot Measuring Cup 8
Gage R&R (1/6) • Experiment setting – pH meter – 3 operators – 3 cups of tea – 3 replicates – Parameters • 3g tea • 200 mL water • 8 min 9
Gage R&R (2/6) • Experiment without SOP – Effect of
operator
is significant – Contributions of total Gage R&R:
nearly 100%
• Repeatability: 62.57% • Reproducibility: 37.43%
Source
Part Operator Part*operator Repeatability Total
DOF
2 2 4 18 26
SS MS
0.01982 0.009911
1.01682 0.508411
0.02482 0.006206
1.7272 0.095956
2.78867
F
1.5971
81.9284
0.0647
P 0.309
0.001
0.992
10
Gage R&R (3/6) • Experiment without SOP 11
Gage R&R (4/6) • Experiment with SOP – Effect of
part
and
interaction
are significant – Contributions of total Gage R&R:
35.21%
• Repeatability: 14.72% • Reproducibility: 20.49%
Source
Part Operator Part*operator Repeatability Total
DOF SS
2 0.005341
MS
0.00267
2 0.001252 0.000626
4 0.000704 0.000176
18 0.001133 0.000063
26 0.00843
F
15.1789
3.5579
2.7941
P 0.014
0.129
0.058
12
Gage R&R (5/6) • Experiment with SOP 13
Gage R&R (6/6) • The gage has acceptable repeatability and reproducibility – Different operations of operators have large influence in R&R – A
proper SOP
is required to improve the performance of operators 14
Project Overview Control Define Improve
Analyze
Measure 15
Design of Experiment (1/2) • • • • 3 4−1 fractional factorial design Response variable: pH value (using pH meter) Tea: 憩园甘露 Initial model: – 𝑦 = 𝜇 + 𝐴 + 𝐵 + 𝐶 + 𝐷 + 𝐴𝐵 + 𝐴𝐶 + 𝐵𝐶 + 𝜖 A B C D
Factor
Temperature (C) Time (min) Volume of water (ml) Material of cup 60 2 50 Glass
Level
80 5 100 Ceramic 98 8 200 Stainless steel 16
Design of Experiment (2/2) • • Sequence of experiment – Three cups of tea are tested in the same period. – The cups are made of different materials. – The total time of each cup is different.
– Measure their PH at their own time point. Control of factors – Temperature: air-conditioner, thermos – Volume of water: measuring glass – Weight of tea: electronic balance 17
Design of Experiment
0 min 2 min 4 min
不锈钢 陶瓷 玻璃
8 min 8-0=8 min 7 min 6 min 7-2=5 min 6-4=2 min
18
Experiment process (1/4) • Experiment notes – Cleaning acidometer & container everytime after reading PH value to get accurate data – Put acidometer into tea at least 1 min before reading to get stable PH value – To save time, we compress 3 experiments into one 8 min cycle, with same water temperature 19
Experiment process (2/4) • Preparation – Make sure the 3 experiments’ parameter combination (3g tea-leaf, same temperature) • 2min, A mL water, B1 container • • 5min, A mL water, B2 container 8min, A mL water, B3 container – Measuring required water & three 3g tea-leaf – Put tea-leaf into 3 container 20
Experiment process (3/4) • Experiment cycle Pour A mL water into B3 container Pour A mL water into B2 container • Pour A mL water into B1 container • • • Read PH value Wash acidometer Put acidometer • • • Read PH value Wash acidometer Wash B1 container • Wash acidometer into B2 container • Wash B3 container 0 min 1 min 2 min 3 min 4 min 5 min 6 min 7 min 8 min Measuring A mL water Measuring A mL water Put acidometer into B1 container • • • • 8 min 5 min 2 min Read PH value Wash acidometer Put acidometer into B1 container Wash B2 container 21
Experiment process (4/4) Measure 3g tea All experiment instruments Experime nt Snapshot s 3 cups per cycle Read PH value 22
Design of Experiment (1/9) • Result of the initial model – All main effects are significant – Three interactions are not significant
Source Temperature Time Volume Material Temperature*Time Temperature*Volume Time*Volume Residual Total DOF Seq SS Adj SS Adj MS
2 0.110289 0.110289 0.055144
2 0.298689 0.298689 0.149344
2 0.877222 0.877222 0.438611
2 0.097356 0.097356 0.048678
4 0.019822 0.019822 0.004956
4 0.018889 0.018889 0.004722
4 0.015422 0.015422 0.003856
6 0.031578 0.031578 0.005263
26 1.469267
F
10.48
28.38
83.34
9.25
0.94
0.9
0.73
P
0.011
0.001
<0.001
0.015
0.5
0.52
0.602
23
Design of Experiment (2/9) • Residual plot 24
Design of Experiment (3/9) • Mean of main effect 25
Design of Experiment (4/9) • Interaction 26
Design of Experiment (5/9) • Result of model without interaction – 𝑦 = 𝜇 + 𝐴 + 𝐵 + 𝐶 + 𝐷 + 𝜖
Source Temperature Time Volume Material Residual Total DOF Seq SS Adj SS Adj MS
2 0.11029 0.11029 0.05514
2 0.29869 0.29869 0.14934
2 0.87722 0.87722 0.43861
2 0.09736 0.09736 0.04868
18 0.08571 0.08571 0.00476
26 1.46927
F P
11.58
0.001
31.36 <0.001
92.11 <0.001
10.22
0.001
27
Design of Experiment (6/9) • Residual plot 28
Design of Experiment (7/9) • Mean of main effect 29
Design of Experiment (8/9) • Residual vs. sequence 30
Design of Experiment (9/9) • • Recommended parameter – Time: 2min – Volume of water: 200ml – Material of cup: Ceramic – Temperature: 98C – Estimated pH: 6.231
Limitation: no consideration on the effect of – Reusing tea – Type of tea 31
Project Overview
Control
Define
Improve
Measure Analyze 32
Improve & Control • Improvements line to obtain can be made to the production a recommended PH value – Temperature: 98 ℃ recommended – Time: 2 minutes – Tea/water ratio: recommended 3g tea/200 ml water – Container: change the original stainless steel container to the porcelain container 33
Thanks 2014/06/13 34