Quality Control for Tea Beverage

Download Report

Transcript Quality Control for Tea Beverage

Quality Control for PH of Tea Final Presentation YU Jiayi, CUI Liwen, CHEN Rui, GUO Dingcheng, CAO Qing 1

Project Overview Suggestions

PH

value Control Define DOE Improve Analyze Measure Gage R&R Off-line Experiments 2

Project Overview Control

Define

Improve Measure Analyze 3

Define (1/3) • Study Problem – As the PH value of tea beverage is an important quality index, we would like to study the factors that would affect the PH value through off-line experiments . – We expect to obtain the the recommended values related influence factors to obtain the recommended PH value, thus production of tea beverage.

guiding the real of 4

Define (2/3) • • Response (

y

) – PH value of tea beverage • Green Tea: PH value of 6.2 recommended Factors (

x

) – Temperature – Time – Percentage of Tea – Container (stainless steel, glass, ceramic, etc.) 5

Define (3/3) • Methodology: Design of Experiment – Off-line experiments – Gage R&R study – GLM • Identify significant factors • Specify relationships between

x

and

y

6

Project Overview Control Define Improve Analyze

Measure

7

Measurement Instruments Electronic PH-meter Electronic Scale Temperature-control Pot Measuring Cup 8

Gage R&R (1/6) • Experiment setting – pH meter – 3 operators – 3 cups of tea – 3 replicates – Parameters • 3g tea • 200 mL water • 8 min 9

Gage R&R (2/6) • Experiment without SOP – Effect of

operator

is significant – Contributions of total Gage R&R:

nearly 100%

• Repeatability: 62.57% • Reproducibility: 37.43%

Source

Part Operator Part*operator Repeatability Total

DOF

2 2 4 18 26

SS MS

0.01982 0.009911

1.01682 0.508411

0.02482 0.006206

1.7272 0.095956

2.78867

F

1.5971

81.9284

0.0647

P 0.309

0.001

0.992

10

Gage R&R (3/6) • Experiment without SOP 11

Gage R&R (4/6) • Experiment with SOP – Effect of

part

and

interaction

are significant – Contributions of total Gage R&R:

35.21%

• Repeatability: 14.72% • Reproducibility: 20.49%

Source

Part Operator Part*operator Repeatability Total

DOF SS

2 0.005341

MS

0.00267

2 0.001252 0.000626

4 0.000704 0.000176

18 0.001133 0.000063

26 0.00843

F

15.1789

3.5579

2.7941

P 0.014

0.129

0.058

12

Gage R&R (5/6) • Experiment with SOP 13

Gage R&R (6/6) • The gage has acceptable repeatability and reproducibility – Different operations of operators have large influence in R&R – A

proper SOP

is required to improve the performance of operators 14

Project Overview Control Define Improve

Analyze

Measure 15

Design of Experiment (1/2) • • • • 3 4−1 fractional factorial design Response variable: pH value (using pH meter) Tea: 憩园甘露 Initial model: – 𝑦 = 𝜇 + 𝐴 + 𝐵 + 𝐶 + 𝐷 + 𝐴𝐵 + 𝐴𝐶 + 𝐵𝐶 + 𝜖 A B C D

Factor

Temperature (C) Time (min) Volume of water (ml) Material of cup 60 2 50 Glass

Level

80 5 100 Ceramic 98 8 200 Stainless steel 16

Design of Experiment (2/2) • • Sequence of experiment – Three cups of tea are tested in the same period. – The cups are made of different materials. – The total time of each cup is different.

– Measure their PH at their own time point. Control of factors – Temperature: air-conditioner, thermos – Volume of water: measuring glass – Weight of tea: electronic balance 17

Design of Experiment

0 min 2 min 4 min

不锈钢 陶瓷 玻璃

8 min 8-0=8 min 7 min 6 min 7-2=5 min 6-4=2 min

18

Experiment process (1/4) • Experiment notes – Cleaning acidometer & container everytime after reading PH value to get accurate data – Put acidometer into tea at least 1 min before reading to get stable PH value – To save time, we compress 3 experiments into one 8 min cycle, with same water temperature 19

Experiment process (2/4) • Preparation – Make sure the 3 experiments’ parameter combination (3g tea-leaf, same temperature) • 2min, A mL water, B1 container • • 5min, A mL water, B2 container 8min, A mL water, B3 container – Measuring required water & three 3g tea-leaf – Put tea-leaf into 3 container 20

Experiment process (3/4) • Experiment cycle Pour A mL water into B3 container Pour A mL water into B2 container • Pour A mL water into B1 container • • • Read PH value Wash acidometer Put acidometer • • • Read PH value Wash acidometer Wash B1 container • Wash acidometer into B2 container • Wash B3 container 0 min 1 min 2 min 3 min 4 min 5 min 6 min 7 min 8 min Measuring A mL water Measuring A mL water Put acidometer into B1 container • • • • 8 min 5 min 2 min Read PH value Wash acidometer Put acidometer into B1 container Wash B2 container 21

Experiment process (4/4) Measure 3g tea All experiment instruments Experime nt Snapshot s 3 cups per cycle Read PH value 22

Design of Experiment (1/9) • Result of the initial model – All main effects are significant – Three interactions are not significant

Source Temperature Time Volume Material Temperature*Time Temperature*Volume Time*Volume Residual Total DOF Seq SS Adj SS Adj MS

2 0.110289 0.110289 0.055144

2 0.298689 0.298689 0.149344

2 0.877222 0.877222 0.438611

2 0.097356 0.097356 0.048678

4 0.019822 0.019822 0.004956

4 0.018889 0.018889 0.004722

4 0.015422 0.015422 0.003856

6 0.031578 0.031578 0.005263

26 1.469267

F

10.48

28.38

83.34

9.25

0.94

0.9

0.73

P

0.011

0.001

<0.001

0.015

0.5

0.52

0.602

23

Design of Experiment (2/9) • Residual plot 24

Design of Experiment (3/9) • Mean of main effect 25

Design of Experiment (4/9) • Interaction 26

Design of Experiment (5/9) • Result of model without interaction – 𝑦 = 𝜇 + 𝐴 + 𝐵 + 𝐶 + 𝐷 + 𝜖

Source Temperature Time Volume Material Residual Total DOF Seq SS Adj SS Adj MS

2 0.11029 0.11029 0.05514

2 0.29869 0.29869 0.14934

2 0.87722 0.87722 0.43861

2 0.09736 0.09736 0.04868

18 0.08571 0.08571 0.00476

26 1.46927

F P

11.58

0.001

31.36 <0.001

92.11 <0.001

10.22

0.001

27

Design of Experiment (6/9) • Residual plot 28

Design of Experiment (7/9) • Mean of main effect 29

Design of Experiment (8/9) • Residual vs. sequence 30

Design of Experiment (9/9) • • Recommended parameter – Time: 2min – Volume of water: 200ml – Material of cup: Ceramic – Temperature: 98C – Estimated pH: 6.231

Limitation: no consideration on the effect of – Reusing tea – Type of tea 31

Project Overview

Control

Define

Improve

Measure Analyze 32

Improve & Control • Improvements line to obtain can be made to the production a recommended PH value – Temperature: 98 ℃ recommended – Time: 2 minutes – Tea/water ratio: recommended 3g tea/200 ml water – Container: change the original stainless steel container to the porcelain container 33

Thanks 2014/06/13 34